ECClite-logoECClite Ecotap Controller Configuration Lite Edition

ECClite-Ecotap-Controller- Configuration-Lite-Edition-PRODUCT

Product Information

Specifications

  • Product Name: ECClite
  • Description: Ecotap Controller Configuration Lite Edition
  • Platform Compatibility: Windows
  • Controller Firmware Requirement: Version V32RXX and up

Product Usage Instructions

Introduction
ECClite is a software application dedicated to owners, installers, and operators of charging stations. It allows for remote configuration of Ecotap charging stations through backend platforms compatible with OCPP.

Setup Requirements

Required Hardware

  • Computer with at least 1x USB connection (type A)
  • USB to TTL cable
  • Ecotap controller (EVC4.x / EVC5.x / ECC.x)
  • 12V DC power supply

Required Software

No specific software requirements mentioned in the manual.

Downloading and Installation

To download the latest version of ECClite and the user manual, visit Ecotap’s official website.

Updating Firmware

Warning: Firmware updates are critical and should be done with caution. Always follow the manufacturer’s instructions to prevent any damage to the controller module. If you are unsure about updating the firmware, consult Ecotap/Legrand for guidance.

FAQ

  • Q: Can ECClite be used on platforms other than Windows?
    A: No, ECClite works only on the Windows platform.
  • Q: Can I downgrade the firmware after updating?
    A: No, it is not possible to downgrade the firmware once updated. Proceed with firmware updates carefully.

ECClite

Ecotap Controller Configuration Lite Edition

Version 1.4, 15-07-2024
[internal & external usage]

Version History

VersionDateAuthor
1.021-03-2024Product Owner (R&D)
1.116-04-2024Product Owner (R&D)
1.21-05-2024Product Owner (R&D)
1.323-05-2024Product Owner (R&D)
1.415-7-2024Product Owner (R&D)
1.517-7-2024Product Owner (R&D)

History of changes:

  • Version 1.0:
    • Creation
    • Chapters 5 to 10 are based on content in the original ECC Manager manual, adapted and made relevant to ECClite.
  • Version 1.1:
    • Add three table references, out of Jack de Veer’s full EVC4 and EVC5 R&D Manuals to the JSON Parameters.
  • Version 1.2:
    • Additional Parameters mentioned in OCPP Dictionary.
  • Version 1.3:
    • Small corrections & Added table 7.
  • Version 1.4:
    • Added note about OCPPInfo field.
  • Version 1.5:
    • Removed content from the Chapter OCPP Connectivity and referred to separate OCPP Connection Configuration.PDF, for more elaborate OCPP Connectivity information.

Introduction

This document serves as a guide for updating firmware and modifying configuration via the ECClite.
With the lite version you can configure settings regarding; Power, Load-management/Grid and internet connectivity.
The lite version also protects you from changing any configuration on the station that could permanently damage it. If you still use the full ECC Manager instead of the lite version, you will do that at your own risk of voiding warranty.
Using ECClite is described step by step and can be applied to the EVC4.x, EVC5.x and the ECC.x controller that run the V32Rx software.
The following topics are addressed in this manual:
  • Required hardware, software and related files.
  • Updating Firmware via the ECClite
  • Sending selected parameters to the controller.

Important!

  • Standard Factory settings .JSON files with selected parameters should always be supplied by Ecotap!
  • If the ECClite software is used in a way other than indicated in the manual, Ecotap cannot guarantee that the controller will work properly.

Primary information – Ecotap Controller Configuration – Lite Edition

ECClite is an application dedicated for owners, installers and operators of charging stations. Everything that can be done on this software tool, must in principle be done via remote commands from your selected backend. As the Ecotap stations are made for convenient remote control, in batch by using OCPP compatible backend platforms. That is especially the case for all parameters needed to determine the power and grid settings that match your charging infrastructure.

In most cases Ecotap manufacturing will have preset all communication data as such the station will automatically make connection to the backend determined in the purchasing process. If you need to check, correct or modify the backend connectivity, or if you can’t access the backend to configure power and grid settings. You will need to use ECClite.
This software toolkit works only on the windows platform and only if the firmware on supported controllers is on version V32RXX and up.
To download the latest version & the manual, click here: https://www.ecotap.nl/ecclite/
Generic information about Updating your Firmware:

To update the firmware, you will need the manufacturer advised .BIN file. You can find the latest published firmware and their release notes on the web page: https://www.ecotap.nl/ecclite/
Mind that you should always check the release notes to evaluate if that firmware file is compatible to your type of controller module.
An update of the firmware of your station is best done remotely and in batch by the charge point operator via his OCPP-backend access.
In cases you need to do it manually, you can use this software toolkit ‘ECClite’.

WARNING: a firmware update is different from commonly known software updates. If you update the firmware in technical terms, you flash the chip memory. That means that it completely rewrites itself. If you interrupt this process by removing power or data cable. Your controller module can brick itself. And become useless. You lose your warranty and need to swap the controller module. If you don’t know what you are doing, always first consult the manufacturer Ecotap/Legrand.

Unlike with OTA (over-the-air) software updates. With firmware, you as owner of the device decide whether or not you want to update your device to the manufacturer advised version.
If you have a stable version running on your charger, it is not advised to update. Only update if you read in the release notes that the update solves a problem hampers your charger operations. MIND that IT IS NOT possible to DOWNGRADE the firmware anymore. Project  specific firmware on custom product should thus NEVER be upgraded!

OCPP Connectivity :
Because Ecotap Charging Stations are infrastructure objects, the OCPP connectivity to the selected backend platform is pre-configured in the factory. If connectivity is lost or connectivity settings are accidentally wiped and/or contracts with the backend provider are terminated and a switch to a new party is needed. You will need to reconfigure connectivity yourself.

To connect an OCPP backend platform, you will need receive information from the platform provider. Namely, the link to the backend. Called an Endpoint.
In most cases it will look like this:

Endpoint URL: wss://devices.ecotap.com/registry/ocpp/NL*ECO*1000
For detailed information about how to configure this endpoint on the Ecotap Controller, we refer to a separate PDF named: OCPP Connection Configuration.PDF. That you can download from:
https://www.ecotap.nl/en/ecclite-ecotap-controller-configuration/

Under the button: OCPP CONNECTION CONFIGURATION

Required Setup

In order to use ECClite and its functionalities, there are several supplies that are required. Make sure these are present before proceeding.

Required Hardware

ProductInfo
Computer (incl. 1x USB connection, type A)To use the ECClite software tool.
USB to TTL cableCable to connect the controller with the computer (cable is proprietary to Ecotap).
Article number: 3510019
Supplied by Ecotap.
Ecotap controller (EVC4.x / EVC5.x / ECC.x)The controller inside the charging station to be programmed/configured.
12V DC power supplyProperly working power supply to power on the controller module inside the charging station.

Required Software

NameVersionInfo
ECClite1.0.0 or later
  • Software for programming and changing configurations on the EVC4.x / EVC5.x / ECC.x controllers that at least have the V32 Firmware.
  • This can be downloaded from the Ecotap Website:https://www.ecotap.nl/ecclite/

Required Files

NameVersionNotes
Factory standard “.Json” file. (optional)Unique per charger model
  • A file containing all (correct) standard settings for selected parameters.
  • To fall back on if you want to go back to factory settings.
  • This should be requested from Ecotap. Depending on the model of
station you are using.
“.bin” file (optional)V32RXX or later
  • A file containing the (new) firmware. Required for updating firmware.
  • This should be requested from Ecotap.
    Only the latest releases can be downloaded from the website: https://www.ecotap.nl/ecclite/
  • Older version / ‘Legacy firmwares’, can be requested at your technical advisors at Ecotap.

Preparing The Setup

The first step is to unzip the ECClite.EXE, to a folder on your PC or to a USB Stick.
Download the ECClite.zip file and save it to your computer. When doing so, choose a location that is easy to find on your PC.

ECClite-Ecotap-Controller- Configuration-Lite-Edition- (3)Figure 5.1 – ECCmanager.zip file.
(The zip-file icon may look different) Right-click on the file and select Extract All.
An additional screen will now open, click extract again.
In the same location as the .zip file, there will now be a folder created with the same name. ECClite-Ecotap-Controller- Configuration-Lite-Edition- (4)Figure 5.2 – ECCmanager folder after unzipping zip file.
Open this folder and then double-click ECClite.exe to open the application. ECClite-Ecotap-Controller- Configuration-Lite-Edition- (5)Figure 5.3 – ECClite application.
ECClite will now start up and is ready to use.
As you can notice there is no installer needed. This software toolkit works as a pocket ‘lite’ version.
Note: when opening the application, it could occur that Microsoft Defender prevents the starting of it. If this is the case, see Chapter 9 on how to solve this easily.
ECClite-Ecotap-Controller- Configuration-Lite-Edition- (6)Do not power on the module yet, during the following steps!

Connect the USB to TTL cable with the controller.
Attach the USB side of the cable to one of the computer’s USB ports. At the other end of the cable, attach the green connector (to which the black, orange and yellow wires are connected) directly to the module. When doing so, make sure the connector is attached to the pins of the RFID2 reader, see the sticker with I/O layout on the controller:
For the EVC4.x controller: ECClite-Ecotap-Controller- Configuration-Lite-Edition- (7)Figure 5.4 – Connecting the USB to TTL cable to the controller (EVC 4.x).
For the EVC5.x/ECC.x controller: ECClite-Ecotap-Controller- Configuration-Lite-Edition- (8)Figure 5.5 – Connecting the USB to TTL cable to the controller (EVC 5.x).

Establish Communication with the Module.

Before changing the configuration, find out which COM port is used for serial communication. If the USB is not already connected to the computer and/or to the controller, do so first (see chapter 5).
Once the USB to TTL cable is connected to the computer, use the following key combination on the keyboard: ECClite-Ecotap-Controller- Configuration-Lite-Edition-28
This will reveal the following screen. ECClite-Ecotap-Controller- Configuration-Lite-Edition- (9)

Figure 6.1 – Pop-up window after clicking [Windows + X] key combination.

Next, click on Device Manager.
Look for the Ports (COM & LPT) heading and ‘double-click’ on it (or once on the arrow to the left of the name).
The visual representation of the menu’s depends on the operating system that is used, and therefore can differ. ECClite-Ecotap-Controller- Configuration-Lite-Edition- (10) ECClite-Ecotap-Controller- Configuration-Lite-Edition- (11)In case more than one “USB Serial Port (COMx)” are displayed, you can check which port is used for the controller. Simply disconnect the USB to TTL cable from your PC, and re-connect it: the COM port that disappears and appears again is the correct one.
In the example above, only one USB to TTL cable has been connected to the computer. So here, the COM port we are looking for is COM8. Note that the COM port may vary depending on the following (so always check the COM port first):

  • The USB to TTL cable (with controller) is connected to another computer.
  • A different USB to TTL cable is used.

 Open ECClite.

  • ECClite-Ecotap-Controller- Configuration-Lite-Edition- (12)Enter the COM number, which we looked up earlier, in the field next to USB port. So, in the case of this example, we enter 10 here. ECClite-Ecotap-Controller- Configuration-Lite-Edition- (13)
  • Now click on the Connect button at the bottom right of the ECC Manager, and then make sure the checkmark for Debug is checked (at the bottom left of the ECC Manager). ECClite-Ecotap-Controller- Configuration-Lite-Edition- (1)
  • Connect the 12V+ pin of the controller, to the 12V+ of the DC power supply. Connect the “DC power GND pin” on the controller to the ground of the DC power supply.

Next, power on the controller.
After a couple of seconds, logging will appear in the lower display of the ECClite (lines of blue text).

ECClite-Ecotap-Controller- Configuration-Lite-Edition- (14)If you don’t see blue text, remove power from the module, wait 10 seconds, and turn the power back on. Now the blue text should still become visible.

Firmware Update

This section describes how to update the controller’s firmware via ECClite.

It is important that, during the update process, the USB to TTL cable remains connected to the PC and/or controller and that the controller is continuously powered-on (provided by the 12V DC supply)!

Pre-requisites:

  • Download the “.bin” file and save it to an easily retrievable place on the PC.
  • Make sure there is communication with the module, see chapter 6 (blue log text).

Only continue when the pre-requisites are met.

  1. Open ECClite Click the “Update” tab and then “Open Firmware file”.ECClite-Ecotap-Controller- Configuration-Lite-Edition- (15)
  2. Look-up the .bin file and open it.
  3. Check that the software version name matches the name of the .bin file, as now displayed in ECClite (see image below). In this example, the module will be updated to the V32R16 firmware.
  4. ECClite-Ecotap-Controller- Configuration-Lite-Edition- (16)Click on “Program firmware”.
    • Now software info (in green) will appear in the logging. Also, a progress bar at the bottom of ECClite will start running. This indicates how far the update has progressed. Wait for it to fill up. ECClite-Ecotap-Controller- Configuration-Lite-Edition- (2) When the progress bar is completed, green text is displayed again followed by a piece of red text. This is internal info of the module, characterized by ‘copy flash’ and ‘erase’ remarks in the loggingECClite-Ecotap-Controller- Configuration-Lite-Edition- (17)
  5. Verify the controller’s firmware version.
    • It can be found in the application’s startup information (blue text), after about 20 lines. Seeimage below (based on an EVC 4.31 controller).ECClite-Ecotap-Controller- Configuration-Lite-Edition- (18)

During boot of the application, the V32R16 is shown in the logging; it has been successfully installed.
It is important that, during the update process, the USB to TTL cable remains connected to the PC and/or controller and that the controller is continuously powered-on (provided by the 12V DC

Load and Send Configuration to the Module.

A configuration that is incorrect or incorrectly set, can permanently damage the controller and Ecotap cannot be held responsible for this. When in doubt, always contact Ecotap up front.

Download the factory standard .json file provided by Ecotap, for the exact station model you have at hand. Save it somewhere on the PC, where the file can be found easily. As an example in this manual, we will use “test.json”. Again, only use the factory standard .json file provided by Ecotap specifically for that station model!

 

ECClite-Ecotap-Controller- Configuration-Lite-Edition- (19)(The icon of the .json file may look different)
In ECClite, go to the Settings tab, and then click the ECClite-Ecotap-Controller- Configuration-Lite-Edition- (20) button. ECClite-Ecotap-Controller- Configuration-Lite-Edition- (21)Now the explorer will open. On your PC, search for the location where the .json file was placed earlier.
Next, click on the file and click Open.

ECClite-Ecotap-Controller- Configuration-Lite-Edition- (22)It will show a selection of parameters that Ecotap has specified for you within the Json file. For these selected configuration keys, you can adjust the values. Below an example is given with dummy values.ECClite-Ecotap-Controller- Configuration-Lite-Edition- (23)

  • Adjust the values of these parameters, if applicable. When in doubt, always contact Ecotap!
  • When the values are entered correctly, click the Select All button.
  • This selects the parameters, identified by the checked box to the left of the parameter names.

Then click the Send selected button, which sends these parameters with their values to the module. ECClite-Ecotap-Controller- Configuration-Lite-Edition- (24)Now check the logging again, for the specific code line “SV CFG()”. This indicates that the configuration change has successfully been accepted. ECClite-Ecotap-Controller- Configuration-Lite-Edition- (25)Next, to validate if the configuration has changed. Reboot the controller. Wait a couple of seconds, then proceed to Select all, again and Receive config.
If the parameters are set correctly, the correct values will be read out of the controller module.
Under chapter 11 you will find a dictionary of parameters available for you to modify based on your chargers differing installation situations. Any other parameters that need to be changed should be done remotely from the connected OCPP Back-Office platform.

Troubleshooting

Should any problems arise while following the manual, a possible solution to fix the problem can be found in this section.

‘Windows protected your PC’ message.
It is possible that you might end up with this screen when trying to open ECClite software.
This is a message from Microsoft Defender to protect your computer from malicious software. In this case the software is not malicious but unknown to Microsoft Defender.
To go further with this, click on More info.

ECClite-Ecotap-Controller- Configuration-Lite-Edition- (26)This will show you more info about the application that you want to run. Because we know this software is not malicious you can click on the Run anyway button. After this, the application will start as expected. ECClite-Ecotap-Controller- Configuration-Lite-Edition- (27)

JSON Configuration Dictionary

ECClite supports JSON Get and Set configuration. The configuration items consist of OCPP parameters and Ecotap proprietary parameters and can be set via OCPP (Open Charge Point Protocol). The OCPP parameters can be found in the appropriate OCPP standard. Below you will find Ecotap’s implementation of these parameters.
Mind that in the input value of these parameters, if you have a comma “ , ”. That means that after that comma will be the next input value. So, with the chg_RatedCurrent = [16,16]. That means left channel is on 16 amps and the right channel is on 16 amps as well. Keep that in mind.

Parameters underECClite-Ecotap-Controller- Configuration-Lite-Edition-27 in ECCLite, can and must only be changed by the CPO via it’s connected Backend Platform / Central System!

Configuration KeyR/WDescription
authorizationKeyWOHere the authorization for a secure WebSocket must be entered.
The key can only be written to and cannot be read out for security reasons
The option ‘useTLS’ must be set to use the key.
The firmware uses Basic Authentication for HTTPS connections and hence the key must be entered as follows:
Format: <username>:<password>
<username>       Username as known by the Central System
<password>        Password as known by the Central System
Example Authorization Key:
ECOTAP-1802500:9N8gGyS8Un7g4lY9dRICK
chg_DebugRWSet debug logging options. (CSL)
See Table 1: Debug options and levels for the allowed options and their levels.
The value of an option must be entered as a bitmask where each bit represents a debug level. The following levels are implemented:
  • 0 = Off
  • 1 = Level 1
  • 2 = Level 2
  • 4 = Level 3
  • 8 = Level 4
  • 16 = Level 5

To enable multiple levels add them together e.g.: to enable Level 1 and Level 3 enter the value 5 = 1 +4
Example of a debug configuration:
warn=1,error=1,date=1,syslog=0,gsm=1,events=1,com=0,ocpp=0,eth=0,grid=0,ctrl=3,general=3,
sensors=0,fw=0,modbus=0,canbus=0,sys=0

chg_KWH1 chg_KWH2 chg_KWH3Energy meter configuration for channel 1, channel 2 and the utility meter (KWH3)
Format: <type>,<address>,<speed>,<parity>,<stop-bits> where
<type>              Energy meter type & brand
(Only the meters compatible to the applied Ecotap Firmware version)
<address>         Modbus address in case of a Modbus meter
<speed>            Modbus meter: Baudrate
Pulse meter: Number of pulses per kWh
<parity>            (N)one, (E)ven, (O)dd (Only for Modbus meters)
<stop-bits>        1 or 2 (Only for Modbus meters)
Example for utility meter:
EASTR_SDM72D,3,9600,N,1
chg_Reader1 chg_Reader2RWToken Reader type (CSL)
The ECC supports one reader per channel and each reader can be set to support channel 1, channel 2 or any of those channels. When set to any, the ECC will check which channel gets a valid PP or CP signal and then assigns the token reader to that channel. Hence only one reader is needed..
Format: <type>,<channel> where
 

<type>              Reader type

See Table 5: Supported Token Reader

<channel>         Channel. Set to either CH1 or CH2 or any

 

Example for a charger with two readers:
chg_Reader1: sl032,CH1 chg_Reader2: sl032,CH2

Example for a charger with a shared reader:

  • chg_Reader1: sl032,any
  • chg_Reader2: none,CH2
chg_MinChargingCurrentRWThe minimal current allowed to charge an EV. (CSL)

Value is the current per phase for all phases in amps. Range = 0…63
Example for a standard charger :
6

chg_RatedCurrentRWThe rated current for a channel (CSL)
This is the rated current of the channel in amps as determined by the wiring and other hardware of the charger and will normally be the same as the MCD for this channel. The current delivered to the EV will never be higher than this value.
Example for a standard charger:
16,16
chg_StationMaxCurrentRWThe maximum current that a charger may consume in total per phase for all phases in amps.

The value of this setting may not exceed the maximum current allowed by the wiring of the charger model. However, when the connection to the utility grid has a fuse with a smaller rating, the value of this rating must be used. This often happens for public chargers which can carry up to 32A but are fused with 25A.
Example for a public charger fused with 25A:
25

chg_Ch1Options chg_Ch2OptionsRWCharger options for a channel. (CSL)
See Table 6: Charger Channel Options for the allowed options. 0 = Option disabled, 1 = Option enabled.
Example:PlugAndCharge=0,OvercurrentSens=0,StopOnChargeComplete=0, OfflineStopOnDisconnect=0,
StopOnLowCosphi=0, Rel2OnLowCosphi=0
com_OptionsRWCommunication Options (CSL)

See Table 7: Communication options for all allowed options. 0 = Option disabled, 1 = Option enabled
Example for a standard charger:
Events=1,BlockBeforeBoot=1,Wdt=0,updSendInIdle=0,blockLgFull=0,useTLS=0,comMaster=0

com_EndpointRWEndpoint for the central system
In the definition of the endpoint the user may define two variables:
#SN#                 Replaced by the serial number of the controller module #OSN#              Replaced by the OCPP ID of the controller module
Example:
ws.evc.net:80/#SN#
com_OCPPIDRWOCPP Identification ID (Maximum length = 25 characters)
When the ID is changed the charger will restart after 60 seconds.
Example:
EcotapTestID
com_OCPPInfoRWOther info needed for the OCPP Protocol (CSL)
See Table 3: Additional OCPP vendor information for the allowed fields.
Example:
modelname=ECC-AC,vendorname=Ecotap,CpSn=G48229*1
com_ProtChRWCommunication channel for the Central System
Example for a standard charger, connection via the modem: GSM
Example for a standard charger where Ethernet interface is used:
ETH
com_ProtTypeRWCommunication protocol for the Central System See Table 2: Supported communication

 

Example for a standard charger:

OCPP1.6J

eth_cfgRWEthernet Interface configuration (CSL)

 

Format: type=<type>,ip=<ip>, netmask=<netmask>,dns=<dns>,gw=<gw> where

 

  • <type>                      IP address type Enter ‘static’ or ‘dhcp’
  • <ip>                         IPV4 address of the EVC4
  • <netmask>                IPV4 netmask
  • <dns>                       IPV4 address of the domain name server
  • <gw>                        IPV4 address of the gateway

Example:

Type=dhcp,ip=0.0.0.0,netmask=0.0.0.0,dns=0.0.0.0,gw=0.0.0.0

grid_InstallationMaxcurrentRWThe maximum current allowed for a master/slave grid (per phase for all phases) in amps. Range 0…9999

This option must be set on a master to the value for that master/slave grid. This option must be set on a supervisor to the current available for all grids.
Example:
250

grid_InstallationSaveCurrentRWThe maximum current allowed for a master/slave grid (per phase for all phases) in amps when the master loses communication with the supervisor.
Range 0…9999
Must be set on a master and is only used there..Example:
100
grid_RoleRWOperation mode in a local power grid

See Table 4: Grid roles for the allowed roles.
Example for a standard charger:
Station_ctrl

gsm_APNRWGSM APN Information

Format: <APN name>,<APN user>,<APN password>
The name is limited to 39 characters while the user and password are limited to 24 characters.
Example for a standard charger:
m2mservices,,

gsm_OperRWGSM Preferred Operator for the mobile network

Set to 0 (default) if automatic selection is preferred otherwise it should be formatted as LLLXX, where LLL is the country code and XX is the provider code.
For the Netherlands possible values are 20404 (Vodafone NL), 20408 (KPN NL), 20416 9T-Mobile NL)
Example for a standard charger:
0

gsm_OptionsRWGSM options (CSL)
0 = Disabled, 1 = Enabled
The following options are allowed:Option            Description

noSmsChk       If enabled allows all originating numbers to send SMS commands

If disabled only the number set in parameter ‘gsm_SMS’ may send SMS commands.

AutoAPN         Only present to prevent errors with older configurations. Now obsolete. 3G4G              Only present to prevent errors with older configurations. Now obsolete.

Example for standard grid
noSmsChk=0,AutoAPN=0,3G4G=0

gsm_SigQROGSM signal quality(0..99). Must be greater than 8 to have a valid GSM connection. A value of 99 means that no strength could be determined.
Example for a standard charger:
15

Chg_Debug Levels :

OptionLevelsDescription
warn1Show warnings. Default set to level 1
error1Show errors. Default set to level 1
date1Show data and time before each line.
syslog1Log syslog entries
gsm1…3Log mobile communication
events1…4Log event system info
com1…4Log communication info
ocpp1…3Log OCPP info
eth1…3Log ethernet info
grid1…4Log power grid info
ctrl1…3Log charger control
general1…2Log general events
sensors1…2Log sensors
fw1…2Log firmware update info
modbus1…2Log Modbus info
canbus1…3Log CAN-bus info
sys1…3Log sys info

Com_ProtType :

OptionDescription
LMSProprietary LMS protocol. (Deprecated. Only still used for Master/Slave grids)
OCPP1.5JOCPP Versie 1.5 JSON. (Deprecated)
OCPP1.6JOCPP Versie 1.6 JSON.
ClearClear all events in the event buffer without changing the current protocol.
Used to clear old events before switching to a new protocol to prevent protocol errors on the Central System.
Recommended to use when switching from LMS to OCPP and vice versa.

Com_OCPPInfo :

OptionDescriptionMaximum Length
modelnameCharge point model name25 characters
vendornameCharge point vendor name25 characters
CpSnCharge point serial number25 characters

Grid_Role :

OptionDescription
No_ctrlThe controller module disables the internal power manager
Station_ctrlThe controller module uses the internal power manager for the station only.
The configuration key ‘chg_StationMaxCurrent’ will be used to limit the maximum power
SlaveThe controller module will function as a slave that will connect to a master/supervisor.
The configuration key ‘chg_StationMaxCurrent’ will be used to limit the maximum power
MasterThe controller module uses the internal power manager for control of the power on the master and the connected slaves.
The configuration key ‘grid_InstallationMaxcurrent’ defines the total current for this master/slave grid

Chg_Reader :

OptionDescription
noneNo reader connected
sl032SL032/SL031 reader or twn4 reader emulating a sl032 reader
SharedShared reader Only used for split systems.

Chg_ChOptions :

OptionDescription
PlugAndChargeEnable Plug & Charge
OvercurrentSensEnable over-current sensing
StopOnChargeCompleteStops the transaction when the EV stops charging
OffLineStopOnDisconnectIf the connection with the central system is lost, stop the transaction as soon as the cable is disconnected from the EV
StopOnLowCosphiStop charging when the cosine ɸ goes low (<0.7)
Rel2OnLowCosPhiSwitch from relay 1 to relay 2 output when the cosine ɸ goes low (<0.7)

Table 6: Charger Channel Options

OptionDescription
EventsEnable status updates (events) to be send to the Central System
BlockBeforeBootBlock the charger until the boot notification message has been sent
WdtEnable Master/Slave communication watchdog.

Only supported by Slaves in a Master/Slave Grid. Should be disabled otherwise.

updSendInIdleSend meter value updates when the charger is idle
blockLgFullBlock the charger when the Transaction Event Log is full
UseTLSSecured web socket connection with the Central System using TLS
comMasterSet this module to be the master and actively put all connected ECCs to slave mode.

This option is obsolete and is only present to prevent errors with older configurations.

Table 7: Communication options