Danfoss VACON 100 X OPT Heater Instruction Manual

VACON® 100 X – HEATER (ARCTIC OPTION)

Document code: DPD01097C

Safety

This manual contains clearly marked cautions and warnings which are intended for your personal safety and to avoid any unintentional damage to the product or connected appliances.

Please read the information included in dangers carefully.

The optional heater allows the drive to operate in low temperature conditions down to -40°C. This option is intended to be installed inside the drive.

Only VACON® authorized, trained and qualified personnel are allowed to install and maintain this component.

Dangers

Table 1. Dangers

Danfoss VACON 100 X OPT Heater - warning symbol The components of the optional heater are live when the element is connected to mains potential. Coming into contact with this voltage is extremely dangerous and may cause death or severe injury.

Danfoss VACON 100 X OPT Heater - warning symbol The heater can be used only inside the drive and in combination with only the VACON® 100 X. Before connecting the heater to mains, make sure that the VACON® 100 X drive is closed firmly.

Technical data

The optional heater has to be supplied with single-phase 230V. The thermal element is always supplied and if the drive is connected at -40°C the drive will be heated up until the temperature of -10°C is exceeded. The heating is temperature controlled and an internal fan ensures that the air is equally distributed inside the enclosure.

The integrated relay output (switching capacity: 24VDC / 3A, 277VAC / 3A) can be used to control the power-up of the drive. The contact is closed when the internal temperature is higher than the minimum allowed value for the power-up (~ -10°C). This can be included and managed in the logic of the entire system. A bi-color LED (on the enclosure of this option), shows the status of the drive, ready or not-ready.

Table 2. Technical inform at ion on input and relay terminals.
Danfoss VACON 100 X OPT Heater - Heater connections Danfoss VACON 100 X OPT Heater - Heater connections

Fuses

The recommended fuse types for the heater supply voltage are shown in the table below.

Table 3. Fuses ratings.
Danfoss VACON 100 X OPT Heater - Fuses rat ings

Mounting instructions: MM4 Example
Danfoss VACON 100 X OPT Heater - Heat er opt ion for MM4
Figure 1. Heat er opt ion for MM4.

Danfoss VACON 100 X OPT Heater - Remove the cable entry plat
Figure 2. Remove the cable entry plat e ( right side example) .

Danfoss VACON 100 X OPT Heater - Remove the powerhead from the terminal box
Figure 3. Remove the power head from the terminal box.

Danfoss VACON 100 X OPT Heater - Connect the supply voltage
Figure 4. Connect the supply voltage ( black cable) and the out put relay ( red cable) to the optional heater through the bottom cable entry plate. Colors of the cables are only examples.

Danfoss VACON 100 X OPT Heater - Mount the optional heater
Figure 5. Mount the optional heater on the terminal box and then close the power head.

Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/

Documents / Resources

Danfoss VACON 100 X OPT Heater [pdf] Instruction Manual
VACON 100 X OPT Heater, 100 X OPT Heater, OPT Heater, Heater