CONDUCTIX wampfler logoEnergy feed with tension cable
Program 0210 and 0215
Instruction Manual CONDUCTIX wampfler Energy Feed with Tension Cable Program 0210 and 0215

Required tools

1.1 Standard tools
The installation of the energy feeds requires the usual (metric) tools.
1.2 Special tools
To tighten the nuts on flat cable trolleys with split nuts, we recommend the use of the special socket wrench, order no.: 020104. CONDUCTIX wampfler Energy Feed with Tension Cable Program 0210 and 0215 - Figure 1

Installation

CONDUCTIX wampfler Energy Feed with Tension Cable Program 0210 and 0215 - Figure 2

Pos. Description
1Cable trolley 0216331/021632
2Holder 020190
3End clamp 020222-080
4Flat cable
5End clamp 020222-080
6Towing part arm 020531
7Towing part 021611

2.1 Installing the energy feed
There are two types of cable end fastener:
A Tension cable end fastener with two split nuts
B Tension cable end fastener with split nut and redirection roller

Slack h [% of 1]Recommended variant¹)
Program 210Program 215 (1 tension cable)Program 215
(2 tension cables¹))
0.63
0.80
1.00
1.25
Not recommendedB
B
B
B
B
B
B
B
1.60
2.00
2.50
3.20
A
A
A
A
A and B
A and B
A and B
A and B
B
B
B
B

1)For applications in which a constant cable slack must be ensured even during temperature fluctuations, variant B must alwaysbe selected
2)Both cables run through a compensating roller on a counterweight as an endless loop CONDUCTIX wampfler Energy Feed with Tension Cable Program 0210 and 0215 - Figure 3

Pos.Description
1Towing arm

2.1.1 Tension cable end fastener with two split nuts

  • Screw both cross arms to the customer-provided structure.
  • Insert the tension cable into one of the opened split nuts and fasten it with cable clamps.
  • Place the premounted split nuts into the cross arm.
  • Thread the towing part and the cable trolley onto the tension cable.
  • Assemble the loose end of the tension cable with the remaining split nut, insert into the cross arm, and secure it against slipping out.
  • Insert the towing part arm into the towing part and screw it onto the mobile consumer.
  • Attach the end clamp on the feed side and start to lay the cables (see 2.2).
  • Once the cables are clamped into the cable train, the cable is clamped onto the clamping bolts by tightening the nuts.

2.1.2 Tension cable end fastener with split nut, redirection roller, and clamping weight

  • Insert the tension cable into the opened split nut and fasten with cable clamps.
  • Place the premounted split nuts into the cross arm and tighten it.
  • Thread the towing part and the cable trolley onto the tension cable.
  • Guide the loose end of the tension cable is guided over the redirection roller and clamp it to the counterweight.
  • Insert the towing part arm into the towing part and screw it onto the mobile consumer.
  • Attach the end clamp on the feed side and start to lay the cables (see 2.2).

2.1.3 Installation of cable trolleys 021111, 021112, 021115, 021116, and 021117 (conditional)
Cable trolleys can be installed with a clamped cable or wire:
→ Remove the screw and roller and spread the cable trolley apart.CONDUCTIX wampfler Energy Feed with Tension Cable Program 0210 and 0215 - Figure 4→ Guide the cable trolley upwards, push it together on the sides, and insert the roller. CONDUCTIX wampfler Energy Feed with Tension Cable Program 0210 and 0215 - Figure 5→ Tighten the screws. CONDUCTIX wampfler Energy Feed with Tension Cable Program 0210 and 0215 - Figure 6For cable trolley 021111 or 021112, cable collars 020111/020114 or connector eye 020113 are inserted, and the hook is pushed together at the end.

2.2 Installing cables
warning - 1 WARNING!
An electrician must perform the electrical connection of the system!

  • Mark the cable(s) (for example using chalk) to show the fixed installation length and then for the loop lengths lloop (see project documentation).
  • Lay the cables into the cable holder starting from the end clamp.
  • While aligning the cables, be sure that the markings on the cables are in the middle of the saddles. Repeat this procedure for all cables.
  • Clamp the cables by tightening the nuts.
  • Connect the cables and start the cable train system.

CONDUCTIX wampfler Energy Feed with Tension Cable Program 0210 and 0215 - icon 1 If multiple flat cables must be laid per cable trolley, the flat cable with the greatest thickness (usually the main power cable) must be placed topmost.
CONDUCTIX wampfler Energy Feed with Tension Cable Program 0210 and 0215 - icon 1 For round cables, the cables with the largest diameters are suspended directly under the cable trolleys, while all other cables are suspended below them in order of diameter. CONDUCTIX wampfler Energy Feed with Tension Cable Program 0210 and 0215 - Figure 7

Pos.Description
1Main power cables
2for flat cable trolleys
3for round cable trolleys

→ Once the cables are clamped into the cable train, they can be connected to the consumer and to the feed.
2.3 Interface to the mobile consumer – setting up the towing part
To tow the energy feed, a towing arm is mounted on the mobile consumer. This engages into the towing part placed at the end of the energy feed.
2.4 Preassembly as an alternative
The energy feed can also be ordered completely preassembled. The preassembled cable train is simply placed into the tension cable mounted on-site and connected. Please ask our preassembly service about this option.
2.5 Example of an energy feed with flat cable saddles (flat or round lines, hoses next to one another) CONDUCTIX wampfler Energy Feed with Tension Cable Program 0210 and 0215 - Figure 8

Pos. Description
1End clamp 021163
2Cable trolley 021113/021114
3Flat cable
4Towing part 021127
5Towing part arm 021136
6Towing part arm 020195
7Towing part 021123

2.6 Example of an energy feed with round cables, spiral hoses (in separate cable holders)
For round cables, the cables must be inserted into the cable holder without any twisting. CONDUCTIX wampfler Energy Feed with Tension Cable Program 0210 and 0215 - Figure 9

Pos. Description
1Cable trolley with collar or holder
2End clamp 021164
3Cable holder 020131
4Round cable
5Towing part 021126
6Towing part arm 021136
7Cable trolley with cable holder
8Cable holder 020131
9Towing part arm 020195
10Towing part 021124

Testing during installation

During installation of the cable system, it is recommended that one of the cable trolleys provided be used to verify problem-free movement.

Conductix-Wampfler GmbH
Rheinstraße 27 + 33
79576 Weil am Rhein – Märkt
Germany
Phone: +49 (0) 7621 662-0
Fax: +49 (0) 7621 662-144
info.de@conductix.com
www.conductix.com
uk ca iconImporter for the United Kingdom:
Conductix-Wampfler Ltd.
1, Michigan Avenue
Salford
M50 2GY
United Kingdom
Phone: +44 161 8480161
Fax: +44 161 8737017
info.uk@conductix.com
www.conductix.com

Order number: 0211xx-…
MV0200-0007b-EN
www.conductix.com
translated document

Documents / Resources

CONDUCTIX wampfler Energy Feed with Tension Cable Program 0210 and 0215 [pdf] Instruction Manual
Energy Feed with Tension Cable Program 0210 and 0215, Energy Feed with Tension Cable Program, Energy Feed, Tension Cable Program Energy Feed, Tension Cable Program, 0210, 0215

References

Leave a comment

Your email address will not be published. Required fields are marked *