BEA LZR-MICROSCAN T Door Control Wiring Matrix
BEA LZR-MICROSCAN T Door Control Wiring Matrix

BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS

BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose.

BEA, Inc. strongly recommends that installation and service technicians be AAADM certified for pedestrian doors, IDA-certified for doors/gates, and factory-trained for the type of door/gate system.

Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/device system performance is compliant with local, national, and international regulations, codes, and standards.

Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer’s recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code).

Verify that all appropriate industry signage, warning labels, and placards are in place.

Logos

Pwr Harness (20.5095)Door Control Harness (20.5222)System Harness (20.5304)
RBkGYWGYWOOGyP
RRRGyBl
POWER 1ACT (N.O.)ACT (N.C.)ACT (COM)STALL (N.O.)STALL (N.C.)STALL (COM)HOME
see note 2
HOME
see note 2
PUSH PLATEMONITORING 3
Besam ETIK 430.5558131215/1716/18DPSConnect any dry-contact, knowing act device to the 2 gray wires.
Be certain to turn on Knowing Act at the hub.
Not supported.
Besam MP/CUP30.55583454DPSNot supported.
Besam Power Swing/EXB30.5558TB3-21TB3-20TB4-29TB4-26DPSNot supported.
Besam SM 900/CU230.555813TB1-73DPSNot supported.
Assa Abloy SW 100/200, Ditec HA9 524V+GNDCU-ESD 2CU-ESD 1EXU-SA 3EXU-SA1EXU-SA 7EXU-SA 8Refer to BEA product User’s Guide and OEM manual.
CONDOR30.5558ACTIVATE 17COM 16DMS OCOMMON NDPSNot supported.
DCU DC700
Access Auto. ES500 Quad Systems ES500
30.5558CN2 #2CN2 #3CN6 GREENCN6 BLACKDPSNot supported.
Detex BS1000S/UDC10030.55582151DPSNot supported.
Dor-O-Matic30.5558YELLOWGRAYPURPLEGRAYDPSNot supported.
Dorma 400/70030.5558TRIGGERGNDSWINGGNDDPSNot supported.
Dorma ED 100/250 6134231539798Refer to BEA product User’s Guide and OEM manual.
Gyrotech/Nabco Magnum30.55586 BLACK5 RED3 VIOLET5 REDDPSNot supported.
Gyrotech/Nabco Opus30.55583252DPSRefer to BEA product User’s Guide and OEM manual.
Gyrotech/Nabco U1930.555861/62RED 7WHITE 6BRED 7DPSNot supported.
Gyrotech 300/400 730.5558BLACKREDWHITEREDDPSNot supported.
Horton 4160-3 830.5558BLACKWHITEDAUGHTER BOARDDAUGHTER BOARDDPSNot supported.
Horton 419030.555823103DPSNot supported.
Horton 5190 930.5558CN20

2 = interior

3 = exterior

CN7 COMCN16 ORANGE (10)CN16 YELLOW (9)DPSNot supported.
Hunter HA, Ditec HA830.5558ACTRTNSAFE 2RTNDPSNot supported.
Keane-Monroe K30.5558GREENWHITEYELLOWWHITEDPSNot supported.
LCN Digital / Senior Swing30.5558P6 YELLOWP6 GRAYP2 GREENP2 WHITEDPSNot supported.
Record 6000/8000 1046211011DPSRefer to BEA product User’s Guide and OEM manual.
Stanley “L” 1130.5558ORANGEYELLOWBLUEYELLOWDPSNot supported.
Stanley MP30.55582878DPSNot supported.
Stanley MC 521 1230.5558TB4-4TB4-3TB3-4TB3-3see note 3Refer to BEA product User’s Guide and OEM manual.
Stanley MC 521 Pro and IQ 12TB4-5TB4-6TB4-4TB4-3TB3-4TB3-3see note 3Refer to BEA product User’s Guide and OEM manual.
Tucker30.5558J4-10J4-8 jumped to 12 & 13J4-14J4-8 jumped to 12 & 13J5 – 4 and 5Not supported.
Tormax 130iMotion30.5558INPUT C #2INPUT C #1SAFETY A #2SAFETY A #1DPSRefer to BEA product User’s Guide and OEM manual.
Tormax TDA30.55582878DPSNot supported.
Tormax TTX II30.55585414DPSNot supported.
Note 1If only VAC power is available, a 12V transformer paired with a rectifier must be used. Do not use a 24V transformer and rectifier as this will cause damage to the product.
Note 2Auxiliary Switch: If installing onto a pair or double-egress, ensure to series both home switches. Switches must close when door is closed.
Note 3Monitoring consists of two purple and two blue wires. If monitoring is not used, cap off unused purple and blue wires. Wire as follows:
Door TypeSystem HarnessControl Monitoring
 

Single

1 blue + 1 purple1st leg
1 blue + 1 purple2nd leg
 

Pair / Dual Egress

1 blue + 1 purple1st leg
1 blue + 1 purple2nd leg
Pair / Dual Egress

(independent controls)

2 blues1st control
2 purples2nd control

Effective November 11, 2017: Monitoring is required for ANSI 156.10 compliance.

Note 4
(BESAM ETIK)
Jump 17+18, if not used.
Note 5
(BESAM SW 100/200, Ditec HA9)
Set EXU-SA jumper to “Door open/closed” indication. Jump 1+2 on EXU-SA board.
Blanking Potentiometer must be set fully counterclockwise.
Auxiliary switch may be used for home switch.
Note 6
(DORMA ED 100/250)
Jump 11+3 on control.
Use ON/OFF/H.O. jumper. Control switches must be used. Make certain Home Switch Control Function “Sr” is set to 1.
Note 7
(GYROTECH 300/400)
Set control to “swing-safe.”
Note 8
(HORTON 4160-3)
Must have daughter board.
Note 9

(HORTON 5190)

If using the MICROSCAN On/Off/Hold switch, BEA recommends using CN20 terminal 2.

The CN1 harness will sync two operators so you do not have to use both door control “a” and “b” harnesses.

Note 10
(RECORD 6000/8000)
Jump 11+12 and 14+15.
Note 11
(STANLEY “L”)
The older Stanley, all metal (silver), “L” shape control does not have stall. A control with stall must be used.
Note 12
(STANLEY MC521 / MC521 PRO and IQ)
Jump TB2 2+3 (if not using factory On/Off/Hold Switch).

Customer Support

Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462
General Tech Questions: techservices-us@BEAsensors.com | www.BEAsensors.com

78.6023.02 LZR-MICROSCAN WIRING MATRIX 20240214

Company Logo

Documents / Resources

BEA LZR-MICROSCAN T Door Control Wiring Matrix [pdf] Instructions
LZR-MICROSCAN T Door Control Wiring Matrix, LZR-MICROSCAN T, Door Control Wiring Matrix, Control Wiring Matrix, Wiring Matrix, Matrix

References

Leave a comment

Your email address will not be published. Required fields are marked *