System Components
![]() |
![]() |
| Proximity and Keypad Reader | 1x Hex Key 4 x Plastic wall plug 4 x Countersunk screws 1x Diode and 1 x Capacitor |
Installation
![]() |
Release hex screw from the bottom of the keypad |
![]() |
(Side View) Push the keypad up to release from mount plate |
![]() |
Thread system cable through the cable entry hole then make the system connections (as per the wiring diagram), mount the bracket to the surface and slide the keypad to the mountplate, re-fit the hex screw to secure into position. |
Note: if using more than one keypad, ensure that the keypads are mounted a minimum 185cm apart
Wiring Example

Advanced Programming Guide
How to set-up Access Pin Number and Tags
| Step Number | Action | Keypad Indication |
| 1 | Enter Programming ![]() |
|
| 2 | Enter a starting location number |
|
| 3 | ||
| 4 | Present the tags |
|
| 5 |
How to set the length of the master Pin.
| Step Number | Action | Keypad Indication |
| 1 | Enter Programming ![]() |
|
| 2 | ![]() |
|
| 3 | ||
| 4 | Enter number of digital 2-6 | |
| 5 | To end programming |
Note: When the length of the master code is changed, all existing Pin and Tag will be deleted.
How to set-up Access Pin Number
| Step Number | Action | Keypad Indication |
| 1 | Enter Programming ![]() |
|
| 2 | ![]() |
|
| 3 | ||
| 4 | Enter a starting location number ![]() |
|
| 5 | Enter a 4 digit pin (1234 not be used) |
|
| 6 |
How to set-up Tags in batches (Normal EM125KHz cards)
| Step Number | Action | Keypad Indication |
| 1 | Enter Programming ![]() |
|
| 2 | ![]() |
|
| 3 | ||
| 4 | Enter a starting unused location number * ![]() |
|
| 5 | ||
| 6 | Present all the tags one by one |
|
| 7 | All tags will be auto register To end programming |
*Each tag will use up a location number (the locations must)
How to set-up Tags in batches (Tags in consecutive numbers)
| Step Number | Action | Keypad Indication |
| 1 | Enter Programming ![]() |
|
| 2 | ![]() |
|
| 3 | ||
| 4 | Enter an unused location number* ![]() |
|
| 5 | ||
| 6 | Present the tag with the lowest serial number |
|
| 7 | All other batch tags will auto register To end programming |
*Each tag will use up a location number
Deleting Access Pin or Tag
| Step Number | Action | Keypad Indication |
| 1 | Enter Programming ![]() |
|
| 2 | Enter the location number of tag/pin ![]() |
![]() |
| 3 | ![]() |
|
| 4 |
Changing Programming Pin
| Step Number | Action | Keypad Indication |
| 1 | Enter Programming ![]() |
|
| 2 | ![]() |
|
| 3 | Enter new 4 digit programming pin |
![]() |
| 4 | Re-enter new 4 digit programming pin |
|
| 5 |
Note: To access keypad’s programming mode, the 4 digit programming code is entered in twice
If forgot the password, turn off the power, press and hold button
, connect powert again until
Bi-sound is heard, the password will be reset to default one 1234
Clear all Pin and Tag Data Step Number
| Step Number | Action | Keypad Indication |
| 1 | Enter Programming ![]() |
|
| 2 | ![]() |
|
| 3 | ||
| 4 |
Default to Factory Settings
| Step Number | Action | Keypad Indication |
| 1 | Enter Programming ![]() |
|
| 2 | ![]() |
|
| 3 | ||
| 4 |
Lock 1 Output Operating Time
| Step Number | Action | Keypad Indication |
| 1 | Enter Programming ![]() |
|
| 2 | ![]() |
|
| 3 | Enter number of seconds 00 or 1-99 |
|
| 4 |
I.e.lf setting lock-time as 00 mean, Swipe card or input password once open the door, swipe card or input password again close the door.
Enable & Disable backlight
| Step Number | Action | Keypad Indication |
| 1 | Enter Programming ![]() |
|
| 2 | ![]() |
|
| 3 | ||
| 4 |
Default: Enabled the backlight
Enable ‘Buzzer’ Function
| Step Number | Action | Keypad Indication |
| 1 | Enter Programming ![]() |
|
| 2 | ![]() |
|
| 3 | ||
| 4 |
*Once the “Buzzer” function is disabled, keypad operation becomes mute.
Enable ‘Tamper Alarm’ facility
| Step Number | Action | Keypad Indication |
| 1 | Enter Programming ![]() |
|
| 2 | ![]() |
|
| 3 | ||
| 4 |
Tamper alarm activates the keypad’s internal buzzer and ‘door bell’ output if the light sensor is exposed.
Access Pin Number for Lock 2 Output
| Step Number | Action | Keypad Indication |
| 1 | Enter Programming ![]() |
|
| 2 | ![]() |
|
| 3 | ||
| 4 | Enter an unused location number |
|
| 5 | Enter a 4 digit pin (1234 should not be used) |
|
| 6 |
Deleting Access Pin for Lock 2
| Step Number | Action | Keypad Indication |
| 1 | Enter Programming ![]() |
|
| 2 | ![]() |
|
| 3 | Enter the location number of pin |
![]() |
| 4 | ![]() |
|
| 5 |
Lock Output Operating Time for Lock 2 Output
| Step Number | Action | Keypad Indication |
| 1 | Enter Programming ![]() |
|
| 2 | ![]() |
|
| 3 | Enter number of seconds 00 or 01-99 |
|
| 4 |
I.e.lf setting lock-time as 00 mean, Swipe card or input password once open the door, swipe card or input password again close the door.
User Guide
To release Lock 1

Technical Specification
| DC input | 12 – 24volts |
| AC input | 12 – 24volts |
| Standby current | 80 mA |
| Operating current (without lock) | 110 mA |
| Working temperature | -20c to +50c |
| Reader frequency | 125KHz |
| IP rating | 65 |
| Dimension | 120 x 76 x 28mm |