Ermenrich Verk LY40 Digital Level

Please read the safety instructions and user manual carefully before using this product. Keep away from children. Use the device only as specified in the user manual.

Getting Started

Usage

Acoustic Alert

Calibration

Turn off the device. Place it on a flat surface. Hold the Power/Buzzer button (1) and CAL button (4) down until the CAL icon appears on the LCD. Enter calibration mode. Do not move the device and then press the CAL button (4). The CAL1 icon will appear. Rotate the device 180° and press the CAL button (4). The CAL1 icon will appear again. Calibration is complete when the CAL2 icon disappears. Calibration must be performed on a flat, smooth surface with a slope not exceeding 5°. If it exceeds 5°, the "Err" icon will show, indicating calibration failure.

Note: The device is factory calibrated for maximum accuracy. Users can recalibrate it when necessary.

Specifications

SpecificationValue
Length450 mm
Resolution0.05°
Measuring Range0 to 360° (4x90°)
Measurements°, %, mm/m, in/ft
Accuracy±0.1° at 0° and 90°; the rest: ±0.2°
Auto Off3 min.
Operating Temperature Range0... +40°C / 32... +104°F
Storage Temperature Range-10... +50°C / 14... +122°F
Power Supply2 pcs AAA alkaline batteries

The manufacturer reserves the right to make changes to the product range and specifications without prior notice.

Care and Maintenance

Use the device only as specified in the user manual. Keep away from children. Do not attempt to disassemble the device. For repairs and cleaning, contact your local specialized service center. Protect the device from sudden impact and excessive mechanical force. Do not use the product in explosive environments or near flammable materials. Store the device in a dry, cool place. Use only accessories and spare parts that comply with technical specifications. Never attempt to operate a damaged device or one with damaged electrical parts. If a part of the device or battery is swallowed, seek immediate medical attention.

Battery Safety Instructions

Always purchase the correct size and grade of battery. Replace the entire set of batteries at one time, avoiding mixing old/new or different types. Clean battery contacts and device contacts before installation. Ensure correct battery polarity (+ and -). Remove batteries from equipment not in use for extended periods. Remove used batteries promptly. Never short-circuit batteries to avoid high temperatures, leakage, or explosion. Do not heat batteries to revive them. Do not disassemble batteries. Remember to switch off devices after use. Keep batteries out of reach of children to prevent ingestion, suffocation, or poisoning. Dispose of used batteries according to country laws.

Ermenrich Warranty

Ermenrich products (excluding accessories) carry a 5-year warranty against material and workmanship defects. Ermenrich accessories have a 2-year warranty from the purchase date. The warranty entitles you to free repair or replacement in any country with a Levenhuk office, provided all warranty conditions are met.

For details, visit: ermenrich.com

For warranty issues or assistance, contact your local Levenhuk branch.

Models: LY40, Verk LY40 Digital Level, Verk LY40, Digital Level, Level

PDF preview unavailable. Download the PDF instead.

ermenrich-digital-level-verk-ly40-violet-um-ml Adobe PDF Library 17.0 Adobe InDesign 18.1 (Windows)

Related Documents

Preview Ermenrich Verk LY60 Digital Level User Manual
Comprehensive user manual for the Ermenrich Verk LY60 Digital Level, covering setup, usage, calibration, specifications, care, and safety instructions.
Preview Ermenrich Verk LQ20 Digital Level User Manual
User manual for the Ermenrich Verk LQ20 Digital Level, providing instructions on setup, settings, calibration, specifications, care, and warranty information.
Preview Ermenrich LV50/LV60 PRO Laser Level User Manual
Comprehensive user manual for the Ermenrich LV50/LV60 PRO laser level, detailing features, operation, specifications, and maintenance for accurate measurements in construction and DIY projects.
Preview Ermenrich LT20/LT40 Laser Level User Manual
User manual for the Ermenrich LT20/LT40 Laser Level, covering operation, specifications, safety, and maintenance. Includes multilingual support.
Preview Ermenrich LG900 Site Laser Rangefinder - User Manual & Specifications
Comprehensive user manual and specifications for the Ermenrich LG900 Site Laser Rangefinder. Learn about its features, operation modes, and safety guidelines.
Preview Ermenrich BASE LT10/LT30 Laser Level - User Manual and Specifications
Comprehensive user manual and technical specifications for the Ermenrich BASE LT10/LT30 Laser Level. Learn about setup, modes, specifications, care, maintenance, and warranty information.
Preview Ermenrich LN20 Laser Level User Manual
Comprehensive user manual for the Ermenrich LN20 Laser Level by Levenhuk. Includes detailed operating instructions, technical specifications, safety guidelines, maintenance tips, and warranty information.
Preview Ermenrich LN20 Laser Level User Manual
Comprehensive user manual for the Ermenrich LN20 Laser Level, detailing its features, operation, specifications, safety guidelines, and maintenance instructions for accurate alignment tasks.