APC BX1400UI

APC Back-UPS BX1400UI User Manual

Model: BX1400UI | Brand: APC

1. 서론

The APC Back-UPS BX1400UI is an Uninterruptible Power Supply (UPS) designed to protect your electronic equipment from power outages, surges, and spikes. Featuring Line Interactive Technology and Automatic Voltage Regulation (AVR), this unit provides reliable battery backup and surge protection for connected devices. It includes six IEC 320 C13 outlets, a USB interface for communication, and data line protection.

앞쪽 view of the APC Back-UPS BX1400UI Uninterruptible Power Supply, showing the power button and LED indicators.

그림 1: 전면 view of the APC Back-UPS BX1400UI.

2. 중요한 안전 정보

  • 전기적 위험: 이 장치에는 고용량tage components. Do not attempt to open the UPS casing, especially when connected to power. Refer all servicing to qualified personnel.
  • 직접 연결: Always connect the UPS directly to a wall outlet. Do not use surge protectors, extension cords, or power strips with the UPS input.
  • 통풍: UPS 주변에 적절한 환기가 이루어지도록 하십시오. 환기구를 막지 마십시오.
  • 초기 냄새: A new unit may emit a distinct odor, often described as similar to burnt plastic. This is normal and typically dissipates after a few weeks of continuous operation in a well-ventilated area. It is not indicative of a malfunction.
  • 배터리 교체: User-performed battery replacement during the warranty period will void the product warranty. Refer to the Maintenance section for details.

3. 패키지 내용

패키지에 다음 품목이 포함되어 있는지 확인하십시오.

  • APC Back-UPS BX1400UI Unit
  • Two (2) IEC-C13 to IEC-C14 power cables (for connecting devices to the UPS)
  • 사용 설명서 (본 문서)

메모: The input power cable (for connecting the UPS to the wall outlet) and the USB communication cable are typically 포함되지 않음 and must be purchased separately if needed.

4. 설정

4.1. 포장 해제 및 배터리 연결

  1. UPS를 포장에서 조심스럽게 꺼내세요.
  2. Locate the yellow battery connector on the rear panel of the UPS. This connector is typically disconnected for safe transport.
  3. Push the yellow battery connector firmly into its socket until it clicks into place. This activates the UPS battery circuits.

4.2. 전원에 연결

  1. Connect the UPS to a grounded 230V AC wall outlet using an appropriate IEC-320 C14 input power cable (not included).
  2. Ensure the connection is direct to the wall outlet. Do not use surge protectors or extension cords.
  3. Allow the UPS to charge for at least 10 hours before connecting critical equipment to ensure full battery runtime.

4.3. 장비 연결

The BX1400UI features six IEC 320 C13 outlets for connecting your devices.

  • 배터리 백업 및 서지 보호 콘센트: All six IEC-C13 outlets provide both battery backup and surge protection. Connect your computer, monitor, and other critical electronics to these outlets.
  • 데이터 회선 보호: The rear panel includes RJ-11 ports labeled "DSL/Modem/Fax/Phone" for protecting your telephone or DSL line from surges. These ports are not suitable for Ethernet network connections.
  • USB 인터페이스: Connect a USB Type B cable (not included) from the UPS to your computer for communication and to enable shutdown software functionality.
Rear panel of the APC Back-UPS BX1400UI, showing IEC-C13 outlets, USB port, battery connector, circuit breaker, and data line protection ports.

Figure 2: Rear panel connections of the APC Back-UPS BX1400UI.

5. 사용 설명서

5.1. 전원 켜기 / 끄기

  • 전원을 켜려면: Press and hold the power button on the front panel until you hear a short beep. The UPS will perform a self-test, and the 'On Line' LED will illuminate green.
  • 전원을 끄려면: UPS 전원이 완전히 꺼질 때까지 전원 버튼을 길게 누르십시오.

5.2. LED 표시기

The front panel features LED indicators to show the UPS status:

  • On Line (Green LED): Indicates the UPS is operating on utility power and providing power to connected equipment.
  • On Battery (Yellow LED): Indicates the UPS is operating on battery power during a power outage or brownout. A humming noise is normal during battery operation.
  • Replace Battery (Red LED): Indicates the battery needs to be replaced.
  • Overload (Red LED): Indicates that the connected equipment exceeds the UPS's capacity. Disconnect non-essential equipment immediately.

5.3. 자동 볼륨tage 규정(AVR)

UPS는 미미한 전압 변동을 자동으로 보정합니다.tage fluctuations (sags and surges) without switching to battery power, thus preserving battery life. If voltage fluctuations exceed the AVR's correction range, the UPS will switch to battery power.

6. 주요 특징

  • Line Interactive Technology: Provides stable power by regulating voltage without constantly switching to battery.
  • 자동 볼륨tage 규정(AVR): Corrects minor voltag배터리 전력을 사용하지 않고 변동을 감지합니다.
  • 배터리 백업 : Supplies power to connected equipment during outag에스.
  • 서지 보호: Protects connected devices from damaging power surges and spikes.
  • 6 IEC 320 C13 Outlets: Standard outlets for computer equipment.
  • USB 인터페이스: Enables communication with a computer for monitoring and controlled shutdown.
  • 데이터 회선 보호: Safeguards telephone/DSL lines from surges.

7. 소프트웨어 사용

The APC Back-UPS BX1400UI supports USB Human Interface Device (HID) class specifications, allowing it to be recognized by most operating systems without special drivers.

7.1. APC PowerChute Personal Edition (Windows)

For advanced monitoring and management on Windows systems, download the APC PowerChute Personal Edition software from the official APC web사이트. 이 소프트웨어를 사용하면 다음을 수행할 수 있습니다.

  • Monitor UPS status, power consumption, and battery charge.
  • 장시간 전원이 꺼진 동안 컴퓨터 자동 종료 구성tag에스.
  • Adjust UPS settings, such as alarm behavior (e.g., disable the beeper during battery operation).
  • Perform self-tests to ensure proper UPS functionality.

7.2. Linux Support (apcupsd / NUT)

For Linux environments, the UPS can be managed using `apcupsd` or Network UPS Tools (NUT). These tools provide similar monitoring and shutdown capabilities. Refer to the documentation for `apcupsd` or NUT for configuration details, typically involving specifying `UPSCABLE usb` and `UPSTYPE usb` for `apcupsd`, or using the `usbhid-ups` driver for NUT.

8. 유지관리

8.1. 배터리 교체

The APC Back-UPS BX1400UI uses two 12V 7.2Ah sealed lead-acid batteries. The recommended replacement battery pack is APC RBC113.

  • During Warranty: If the unit is still under its 2-year warranty, battery replacement must be performed by Schneider Electric IT (SEIT) customer service. User-performed battery replacement during the warranty period will automatically void the warranty.
  • After Warranty: After the warranty period, batteries can be replaced by the user. However, due to the presence of high voltage components even when disconnected, it is highly recommended that this operation be performed by specialized personnel. If you choose to replace the batteries yourself, exercise extreme caution.
  • 절차 종료view (for experienced users only): Disconnect the UPS from all power sources and connected equipment. Disconnect the yellow battery connector. Remove the rear panel screws, then the front panel (which is snap-fitted), and additional screws. Carefully access the battery compartment. Note the orientation and wiring of the existing batteries (taking photos is recommended) to ensure correct installation of the new batteries.

8.2. 회로 차단기 재설정

In case of an overload, the UPS may trip its circuit breaker. To reset, disconnect some equipment from the UPS, then press the circuit breaker button located on the rear panel (refer to Figure 2).

9. 문제 해결

문제가능한 원인해결책
UPS가 켜지지 않습니다.Battery connector disconnected; No input power.Ensure yellow battery connector is fully inserted. Verify UPS is plugged into a live wall outlet.
Initial strong odor.New unit manufacturing residue.This is normal. Ensure adequate ventilation. Odor will dissipate over time (typically a few weeks).
UPS emits a humming noise.Operating on battery power; Normal electrical noise.Humming is normal when on battery. If persistent and loud on utility power, ensure proper ventilation and check for loose connections.
'Overload' LED is lit.너무 많은 장비가 연결되어 있습니다.Disconnect non-essential equipment. Press the circuit breaker reset button on the rear panel.
'Replace Battery' LED is lit.배터리 수명이 다해갑니다.Contact APC support or a qualified technician for battery replacement. Refer to Section 8.1.
배터리 작동 시간이 짧습니다.배터리가 완전히 충전되지 않았습니다. 배터리 수명이 거의 다 되었습니다. 과부하가 걸렸습니다.Ensure initial 10-hour charge. Reduce connected load. Consider battery replacement if old.

For more detailed troubleshooting, refer to the complete user manual available on the APC web대지.

10. 사양

특징사양
모델BX1400UI
용량(VA/와트)1400VA / 700W
입력 Voltage230V 교류
입력 주파수50Hz
출력 볼륨tage230V AC (simulated sine wave on battery)
출력 단자6 x IEC 320 C13 (Battery Backup & Surge Protection)
서지 보호 등급273 줄
배터리 유형밀봉형 납산
배터리 구성2 x 12V 7.2Ah
일반적인 재충전 시간8시간 (용량의 90%까지)
Runtime (at 700W load)약 1분
Runtime (at 100W load)약 60분
치수(높이 x 너비 x 깊이)21.5cm x 13cm x 33.6cm
무게4.7kg
인터페이스 포트USB Type B, RJ-11 (Data Line Protection)
Runtime graph for APC Back-UPS 1400VA, 230V, AVR, IEC Sockets (BX1400UI), showing battery runtime in minutes versus load in watts.

Figure 3: Typical runtime graph for APC Back-UPS 1400VA.

11. 보증 및 지원

11.1. 제품 보증

The APC Back-UPS BX1400UI comes with a 2년 한정 보증 구매일로부터. 본 보증은 정상적인 사용 중 발생하는 재료 및 제조상의 결함에 적용됩니다. 보증 청구를 위해 구매 증빙 자료를 보관해 주십시오.

중요한: Unauthorized opening of the unit or user-performed battery replacement during the warranty period will void the warranty.

11.2. 기술 지원

For technical assistance, troubleshooting, or warranty service, please contact APC by Schneider Electric customer support. Visit the official APC website for contact information specific to your region, including phone numbers and online support resources.

Online resources often include FAQs, knowledge bases, and downloadable manuals that can provide further assistance.

Ask a question about this manual