인터매틱 T12404R

Intermatic T12404R DPST Indoor/Outdoor Control Panel User Manual

Model: T12404R | Brand: Intermatic

1. 서론

This manual provides essential information for the safe installation, operation, and maintenance of your Intermatic T12404R DPST Indoor/Outdoor Control Panel. This control panel is designed for managing pool/spa equipment and lighting systems. Please read these instructions thoroughly before installation and use to ensure proper function and safety.

2. 안전 정보

중요한: All electrical installations must comply with the National Electrical Code (NEC) and local electrical codes. For installations in Canada, refer to the Canadian Electrical Code (CEC). Installation should only be performed by a qualified electrician.

  • Ensure proper grounding and bonding of the control panel.
  • Use copper conductors only for all wiring connections.
  • Do not exceed the specified current ratings for the conductors.
  • An approved wiring device must be used inside the enclosure for bonding purposes.
  • An approved rainproof cover must be installed over all wiring compartments to maintain the NEMA 3R rating.
  • Ensure all knockouts are properly sealed after wiring.
  • Always disconnect power at the circuit breaker before performing any installation, maintenance, or service.

3. 제품 오버view

The Intermatic T12404R is a robust control panel featuring two Double Pole Single Throw (DPST) time switches within a NEMA 3R rated enclosure, suitable for both indoor and outdoor applications. It is designed for direct connection to underwater lights and other pool/spa equipment, operating at 240/240 VAC at 60 Hz with a 30 Ampere current rating.

Intermatic T12404R Control Panel with door open, showing two yellow timer dials and manual override switches.

Figure 1: Intermatic T12404R Control Panel with the door open, revealing two yellow mechanical timer dials, manual override levers, and two blank switch plates below the timers. The inside of the door displays wiring diagrams and operating instructions.

4. 설치 및 설정

4.1 장착

The T12404R is designed for panel mounting. Secure the enclosure to a flat, stable surface using appropriate fasteners for the mounting type and location. Ensure the mounting location allows for easy access and proper ventilation.

4.2 배선

All wiring must be performed by a qualified electrician in accordance with all applicable electrical codes. Use copper conductors only. After wiring, ensure the front panel is properly installed over the wiring compartments and all knockouts are sealed to maintain the enclosure's NEMA 3R rating.

  • 전원 공급 장치: Connect the incoming 240/240 VAC, 60 Hz power supply to the designated terminals.
  • 부하 연결: Connect the pool/spa equipment or lighting loads to the output terminals of the time switches.
  • 접지 및 본딩: Ensure all grounding and bonding connections are securely made as required by code.

5. 사용 설명서

The control panel features two independent time switches for automated control of connected devices.

5.1 Setting ON and OFF Times

  1. Locate the trippers on the clock dial.
  2. Hold the trippers firmly against the edge of the CLOCK-DIAL, pointing to the desired ON and OFF times (AM or PM).
  3. Tighten the tripper screws securely to fix their position.

5.2 Setting the Time-of-Day

  1. Gently push the CLOCK-DIAL outward.
  2. Turn the CLOCK-DIAL in either direction until the exact current time-of-day aligns with the POINTER.
  3. Do not move the POINTER itself.

5.3 수동 조작

To manually override the timed operation, move the MANUAL LEVER located below the CLOCK-DIAL to the left or right as indicated by the arrows. This will temporarily switch the connected device ON or OFF, bypassing the set schedule.

5.4 Multiple ON-OFF Operations

For more than one daily ON-OFF operation, additional tripper pairs (Intermatic part number 15671878A) can be installed on the CLOCK-DIAL.

6. 유지관리

정기적인 유지보수는 제어판의 수명 연장과 안정적인 작동을 보장합니다.

  • 청소: Keep the enclosure clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
  • 점검: Periodically inspect all wiring connections for tightness and signs of wear or damage. Ensure the enclosure door seals properly to maintain its weather resistance.
  • 타이머 확인: Occasionally verify that the time switches are operating according to their set schedule.

7. 문제 해결

  • 정전: 정전이 발생한 경우tage, the CLOCK-DIAL will stop. After power is restored, you must manually reset the time-of-day as described in Section 5.2.
  • 장치가 작동하지 않음: Check the circuit breaker for the control panel. Verify that the time switches are set correctly and that the manual lever is not in an override position. Inspect wiring connections for any loose or damaged wires.
  • 타이머가 진행되지 않음: Ensure the clock dial is not obstructed and that the power supply to the timer motor is active.

8. 사양

모델 번호T12404R
제조업체인터매틱 주식회사
인클로저 유형NEMA 3R (방수)
애플리케이션Indoor/Outdoor, Pool/Spa Equipment, Lights
권tage 등급240/240 VAC at 60 Hz
현재 평가30 Ampere (Resistive/Inductive/Tungsten)
Heater Control Circuit10 Amp 240VAC
모터 등급2 HP (24 FLA) - 120 VAC, 5 HP (28 FLA) - 240 VAC
모터볼tage208/277 Volts - 60 Hz
치수(높이 x 너비 x 깊이)12.88 x 10.88 x 4.75 인치(대략)
품목 무게11.3파운드
장착 유형패널 실장
인증CSA(캐나다 및 미국)
필요한 배터리아니요

9. 보증 및 지원

보증: For detailed warranty information, please refer to the manufacturer's official warranty description provided with your product or visit the Intermatic web대지.

고객 지원: If you encounter any issues or have questions not covered in this manual, please contact Intermatic customer support for assistance. Contact information can typically be found on the manufacturer's web사이트 또는 제품 포장.

© 2023 Intermatic Incorporated. 모든 권리 보유.

Ask a question about this manual