Pilz PNOZ X3P Safety Relay Instruction Manual

모델: 777314 | 브랜드: PILZ

1. 서론

This manual provides essential information for the safe installation, operation, and maintenance of the Pilz PNOZ X3P Safety Relay, model 777314. The PNOZ X3P is designed for monitoring E-STOP pushbuttons, safety gates, and light grids in industrial applications, ensuring personnel and machine safety.

2. 안전 지침

경고: Failure to follow these safety instructions can result in serious injury or death, and damage to equipment.

  • Only qualified personnel familiar with industrial safety standards and electrical systems should install, operate, or maintain this device.
  • Disconnect all power before performing any installation, wiring, or maintenance tasks.
  • 모든 배선이 지역 및 국가 전기 규정을 준수하는지 확인하세요.
  • Do not bypass or disable safety functions.
  • Regularly inspect the device and associated safety components for damage or malfunction.
  • Use only genuine PILZ replacement parts.

3. 제품 오버view

The Pilz PNOZ X3P (Model 777314) is a safety relay designed for monitoring safety functions. It features:

  • 기능: E-STOP, safety gate, light grid monitoring.
  • 연락처 구성: 3 Normally Open (NO) safety contacts, 1 Normally Closed (NC) auxiliary contact, 1 Semiconductor Output (SO).
  • 공급량tag전자 범위: 24-240VAC/DC (Coil Voltage: 24V AC/DC).
  • 작동 모드: 자동 재설정.
  • 너비: 45mm.
Pilz PNOZ X3P Safety Relay, front view with terminals and indicators

그림 1: 전면 view of the Pilz PNOZ X3P Safety Relay, showing terminals and indicators.

4. 설정 및 설치

4.1 장착

Mount the PNOZ X3P on a 35mm DIN rail in a control cabinet. Ensure adequate ventilation around the device to prevent overheating. Maintain proper clearance from heat-generating components.

4.2 전기 연결

Before making any electrical connections, ensure the main power supply is disconnected and locked out. Refer to the wiring diagrams for correct terminal assignments.

5. 배선

The PNOZ X3P supports 1-channel or 2-channel wiring for safety inputs. The choice depends on the required safety integrity level (SIL) and performance level (PL).

5.1 Input Wiring (E-STOP, Safety Gate, Light Grid)

  • 1-Channel Wiring: Connect the safety device (e.g., E-STOP) to a single input channel. This configuration offers basic safety.
  • 2-Channel Wiring: Connect the safety device to two independent input channels. This configuration provides redundancy and higher fault tolerance, suitable for higher safety requirements.

5.2 출력 배선

The relay provides 3 NO safety contacts for controlling power to hazardous machinery and 1 NC auxiliary contact for signaling purposes. The 1 SO (semiconductor output) can be used for diagnostic feedback to a PLC.

Ensure that the load connected to the safety contacts does not exceed the maximum switching current of 15 Amps and maximum switching voltag240볼트의 전압.

그림 2: 예ample wiring diagram for a 2-channel E-STOP application. (Actual diagram not provided, refer to product documentation for specific wiring.)

6. 사용 설명서

The PNOZ X3P operates in an automatic reset mode. Once the safety input circuit is closed (e.g., E-STOP released, safety gate closed), the safety relay will automatically energize its output contacts, provided no faults are detected.

6.1 전원 켜기

Upon applying power, the relay performs an internal self-test. If the safety inputs are closed and no faults are present, the output contacts will close, and the status indicators will illuminate.

6.2 안전 기능 활성화

When a safety input is opened (e.g., E-STOP pressed, safety gate opened), the PNOZ X3P immediately de-energizes its safety output contacts, bringing the monitored machine to a safe state.

6.3 재설정

Due to its automatic reset function, the relay will re-energize its outputs as soon as the safety input circuit is restored and no faults are present. Ensure that the machine can only restart safely after a reset.

7. 유지관리

Regular maintenance is crucial to ensure the continued safe operation of the PNOZ X3P safety relay.

  • 정기 검사: Visually inspect the device and its wiring for any signs of damage, loose connections, or contamination.
  • 기능 테스트: Periodically test the entire safety circuit, including the PNOZ X3P, by activating the connected safety devices (E-STOP, safety gate, light grid) to verify their proper function.
  • 청소: Keep the device free from dust and debris. Use a dry, soft cloth for cleaning. Do not use abrasive cleaners or solvents.

8. 문제 해결

If the safety relay does not function as expected, consider the following common issues:

문제가능한 원인해결책
Outputs do not energize after power-up.
  • 전원 공급이 없습니다.
  • Safety inputs open (e.g., E-STOP pressed).
  • 내부 오류입니다.
  • 전원 연결 및 볼륨을 확인하세요tage.
  • Ensure all safety inputs are closed.
  • Contact PILZ technical support.
Outputs de-energize unexpectedly.
  • Safety input opened momentarily.
  • 느슨한 배선.
  • 간섭.
  • Check safety devices for intermittent operation.
  • 모든 배선 연결부를 점검하십시오.
  • Ensure proper grounding and shielding.

If troubleshooting steps do not resolve the issue, contact PILZ technical support.

9. 기술 사양

매개변수
모델777314
상표필츠
작동 모드오토매틱
코일 권tage24 Volts (AC/DC)
접점 전류 등급6 Amps
최대 스위칭 전류15 Amps
최대 스위칭 볼륨tage240 볼트
품목 무게0.64 파운드

10. 보증 및 지원

PILZ products are manufactured to high-quality standards and come with a manufacturer's warranty. For specific warranty terms and conditions, please refer to the official PILZ web사이트를 방문하거나 현지 유통업체에 문의하세요.

For technical assistance, product support, or to report a malfunction, please contact PILZ customer service. Have your product model (777314) and serial number ready when contacting support.