소개
This manual provides essential instructions for the safe installation, operation, and maintenance of your APC AP7922 32A 230V Switched Rack PDU. The AP7922 is a rack-mountable power distribution unit designed to provide advanced power control and monitoring capabilities for IT equipment in data centers and server rooms. It features AC 230V input, Ethernet 10/100 connectivity, and 16 output connectors, all within a 2U, 19-inch form factor.
중요한 안전 정보
Please read and understand all safety instructions before installing or operating this equipment. Failure to follow these instructions could result in electric shock, fire, or serious injury.
- 이 장치는 실내에서만 사용하도록 설계되었습니다.
- Connect the PDU to a properly grounded power source.
- PDU를 열거나 수리하려고 시도하지 마십시오. 모든 수리는 자격을 갖춘 전문가에게 맡기십시오.
- Ensure the total current draw of connected equipment does not exceed the PDU's maximum current rating (32 Amp에스).
- 유지관리나 설치 절차를 수행하기 전에 전원을 분리하세요.
패키지 내용
포장을 풀 때 모든 품목이 있는지 확인하세요.
- APC AP7922 Switched Rack PDU
- 설치 가이드
- 랙 장착 브래킷
- Serial configuration cable
- 문서 CD
제품 특징
The APC AP7922 Switched Rack PDU offers the following key features:
- 전환형 콘센트: Remotely control power to individual outlets for power cycling, delayed sequencing, and load shedding.
- 네트워크 관리: Full-featured network management interface via Ethernet 10/100 for remote monitoring and control.
- 현재 모니터링: Monitor the aggregate current draw per PDU to prevent circuit overloads.
- 랙 장착형 디자인: Occupies 2U of rack space, compatible with standard 19-inch racks.
- 출력 커넥터: Equipped with 16 C13 output connectors.
- 입력 Voltage: Supports AC 230V input.

이미지: 앞면 view of the APC AP7922 Switched Rack PDU, showing the 16 C13 outlets and network interface.
설치 지침
1. 랙 마운팅
- Identify two available 2U spaces in your standard 19-inch equipment rack.
- Attach the provided rack-mounting brackets to the PDU using the screws supplied.
- Secure the PDU into the rack using appropriate rack screws. Ensure it is firmly seated and level.
2. 전원 연결
- Connect the PDU's input power cord to a dedicated 230V, 32A power source. Ensure the power source is properly grounded.
- Do not overload the circuit. Verify that the total load of connected devices will not exceed 32 Amps.
3. 네트워크 연결
- Connect a standard Ethernet cable from the PDU's network port to your network switch or router.
- The PDU will obtain an IP address via DHCP by default. Refer to the full user manual for static IP configuration.
작동 지침
Powering On/Off Connected Devices
Once the PDU is powered and connected to the network, you can manage its outlets remotely.
- Access the PDU's web 인터페이스에 IP 주소를 입력하여 web 브라우저.
- Log in using the default credentials (refer to the full manual for details).
- Navigate to the outlet control section. From here, you can individually switch on, switch off, or cycle power to each of the 16 C13 outlets.
Monitoring Current Draw
그만큼 web interface also provides real-time monitoring of the aggregate current draw. This allows you to ensure that the PDU and its connected circuit are not overloaded.
유지
- 청소: Periodically clean the exterior of the PDU with a soft, dry cloth. Do not use liquid cleaners or solvents.
- 펌웨어 업데이트: APC를 확인하세요 website for available firmware updates to ensure optimal performance and security. Follow the instructions provided with the firmware package for safe updating.
- 케이블 관리 : Ensure all power and network cables are neatly routed and secured to prevent accidental disconnections or damage.
문제 해결
| 문제 | 가능한 원인 | 해결책 |
|---|---|---|
| PDU does not power on. | 전원 입력 없음; 회로 차단기가 트립되었습니다. | Verify the power cord is securely connected. Check the building's circuit breaker for the PDU's power source. |
| 접근할 수 없습니다 web 인터페이스. | Incorrect IP address; network connectivity issue; PDU not powered. | Ensure the PDU is powered on. Verify network cable connection. Confirm the correct IP address. Check network settings. |
| Outlets do not switch. | Software issue; PDU fault. | Try restarting the PDU. If the issue persists, contact technical support. |
| 과부하 경보. | Total current draw exceeds PDU rating. | Disconnect non-essential equipment to reduce the load. Redistribute equipment across multiple PDUs if necessary. |
기술 사양
| 특징 | 세부 사항 |
|---|---|
| 모델 번호 | AP7922 |
| 상표 | Schneider Electric의 APC |
| 폼 팩터 | 2U Rack-mountable, 19-inch |
| 입력 Voltage | 230 볼트 AC |
| 입력 전류 | 32 Amps |
| 출력 볼륨tage | 230 볼트 AC |
| 출력 전류 | 32 Amps(최대) |
| 콘센트 수 | 16 |
| 커넥터 유형 | C13 |
| 네트워크 인터페이스 | 이더넷 10/100 |
| 왓tage | 7360 와트 |
| 치수(높이 x 너비 x 깊이) | 4.49 x 17.52 x 3.5 인치 |
| 무게 | 0.7 킬로그램 |
| 재료 | 금속 |
| 색상 | 검은색 |
보증 및 지원
보증 정보
APC products typically come with a standard manufacturer's warranty. Please refer to the warranty card included with your product or visit the official APC website for detailed warranty terms and conditions specific to the AP7922 model.
기술 지원
For technical assistance, troubleshooting, or to report issues, please contact APC customer support. You can find contact information and additional resources on the official Schneider Electric web대지: