ចម្លើយ

ថ្ងៃទី 28 ខែសីហា ឆ្នាំ 2025 - 05:59 ព្រឹក
1. **Mounting Location:** Select a suitable mounting location for the driver, ensuring it is mounted vertically for proper heat dissipation. The mounting tabs should be at the top, and the wiring compartment should be at the bottom when properly mounted.
2. **Wiring Compartment:** Remove the wiring compartment cover and adjust the knockouts as needed to accommodate the electrical supply type following national and local electrical codes.
3. **Connect Supply Wire:** Strip the supply wire 3/8" and insert each supply wire into the appropriate connector. Connect the black driver wire to hot, the white wire to neutral, and the green wire to ground.
4. **Connect LED Strips:** Connect the LED strips to the driver by inserting the driver output wire into the appropriate connector. Connect the driver's red wire (V+) to the corresponding red wire (V+) from the LED strip and the blue wire (V-) to the corresponding black wire (V-) from the LED strip.
5. **Secure Wiring:** Place all wiring and connectors back in the wiring compartment and replace the cover securely.
6. **Notes on Auto Reset Breaker:** Both primary and secondary circuits are protected with an automatic reset breaker. If a circuit trips, the LED strips will power off, and the reset may take between 50 seconds to 5 minutes depending on the load size.
ដោយអនុវត្តតាមជំហានទាំងនេះដែលមានចែងក្នុង សៀវភៅដៃ, you can ensure a proper and safe connection between the JFX Series Linear Lighting System MLV Driver and the LED strips, maintaining functionality and adhering to safety guidelines.