To select between NO and NC contacts on the ENFORCER S-SS-075Q-10 Emergency-Push-to-Exit ប៊ូតុងសូមអនុវត្តតាមជំហានទាំងនេះ ដោយផ្អែកលើព័ត៌មានដែលមាននៅក្នុងសៀវភៅណែនាំអ្នកប្រើប្រាស់៖
1. SS-075CQ Emergency NO/NC Button:
- This model allows you to select between NO or NC momentary contact.
- To configure the button as NO (Normally Open), you need to set it up for a momentary contact that closes the circuit when the button is pressed.
- To configure the button as NC (Normally Closed), you need to set it up for a momentary contact that opens the circuit when the button is pressed.
2. SS-075C-PEQ Emergency & Push-to-Exit, NO/NC Button:
- This model also allows you to select between NO or NC momentary contact.
- Similarly, to configure the button as NO (Normally Open), set it up for a momentary contact that closes the circuit when the button is pressed.
- To configure the button as NC (Normally Closed), set it up for a momentary contact that opens the circuit when the button is pressed.
Remember to refer to the user manual for detailed installation instructions and wiring diagrams specific to your model. Make sure to test the functionality of the button after installation to ensure it operates as intended based on your selected NO or NC configuration.