ដើម្បីដំឡើង នៅផ្ទះ IP HmIP-FSM Flash Mount Switch Actuator and Meter in a flush-mounting box, follow these step-by-step instructions as outlined in the manual:
1. Switch off the fuse of the power circuit: Before starting the installation, ensure the power circuit is switched off for safety.
2. Connect the actuator to L (E) and N (D) terminals: Connect the actuator to the phase conductor (L) and neutral conductor (N) to obtain power supply.
3. Route the switched phase (C) to the consumer: Connect the switched phase terminal (C) to the consumer device (e.g., lamp) that you want to control.
4. Fix the actuator to the flush-mounting box: Securely fix the actuator in the flush-mounting box. If necessary, you can remove the fixing lug.
5. Close the flush-mounting box: Use an appropriate cover to close the flush-mounting box securely.
6. Switch the fuse of the power circuit back on: This will activate the teach-in mode of the device, as described in the installation instructions.
By following these steps carefully, you should be able to successfully install the នៅផ្ទះ IP HmIP-FSM Flash Mount Switch Actuator and Meter in a flush-mounting box. Remember to always refer to the detailed installation instructions provided in the manual for further guidance and safety precautions.