To set the time function for automatic switching-off of the load on the GIRA 3000 System Zero Voltage Relay Switching Insertសូមអនុវត្តតាមជំហានទាំងនេះ តាមសៀវភៅណែនាំ៖
1. Press the TEST button (1) for longer than 4 seconds.
2. The LED will light up in the color corresponding to the set time (green for function off, white for 1 minute, blue for 5 minutes, yellow for 30 minutes, and red for 60 minutes).
3. Release the TEST button briefly and then press it repeatedly until the LED lights up in the color of the desired time.
4. The set time will be automatically saved after 30 seconds or after pressing the TEST button for approximately 4 seconds. When the LED goes out, the saving process was successful.
By following these steps, you can easily set the time function for automatic switching-off of the load on your GIRA 3000 System Zero Voltage Relay Switching Insert.