When determining the location for installing the , consider the following factors as outlined in the installation guide:
1. **Location Requirements:** The junction box must be installed between rafters. Do not install the junction box directly over a rafter. The sealing area of the junction box must be installed on a flat, coplanar surface. Do not install the junction box sealing area directly on top of a seam, vertical joint, or on two shingle courses or layers.
2. **Drilling into Attic:** Prior to drilling into the attic, ensure that no electrical wires, circuits, or components are on the other side to avoid any accidents.
3. **System Ground Path:** If installing the junction box underneath modules, ensure that the system ground path will not be disturbed or broken during servicing to prevent any potential hazards.
By following these guidelines, you can ensure a safe and proper installation of the ប្រអប់ប្រសព្វ UNIRAC SOLOBOX.