Instruction Manual for dataprobe models including: iBoot-Exp, iBoot-Exp Expansion Unit, Expansion Unit, Unit
File Info : application/pdf, 5 Pages, 415.40KB
DocumentDocumentiBoot-G2+ Expansion Unit 1. General Description The iBoot-Exp is a remote controlled power On / Off switch. It is designed to be controlled by Dataprobe's iBoot-G2+ Web Enabled Power Switch, as an expansion unit. iBoot-Exp handles worldwide power from 105240VAC. It is capable of switching up to 12 Amps at 120VAC and 10 Amps at 220 VAC. Two iBoot-Exp units can be connected and independently controlled by the iBoot-G2+. For complete information, refer to the documentation for the iBoot-G2+. Fig. 1 iBoot Expansion 2. Connections 2.1. Connect iBoot-G2+ iBoot-G2+ has two Expansion Ports, Exp1 and Exp2 for connection to iBoot-Exp, Connections to the iBoot-Exp are made using screw terminal blocks. The screw terminal blocks are on removable connectors for easy cable fabrication. A suitable cable is supplied with the iBoot-EXP. See Specification below for additional connection information. iBoot-G2+ V+ +12 Volts Out I Control Input G Ground O Control Output iBoot-Exp V+ +12 Volts In O Control Output G Ground I Control Input Function Power. iBoot-G2 to iBoot-Exp Status. iBoot-Exp to iBoot-G2+ Common Ground Control. iBoot-G2+ to iBoot-Exp Fig. 2 iBoot Expansion Wiring 2.2. Connect Powered Device Connect the device to be powered ON and OFF to the IEC receptacle marked Switched Outlet. An IEC 320 to North American (NEMA 5-15) power cord is included for connecting the iBoot-G2 outlet to the device to be controlled. Make sure that the combined load of all controlled devices does not exceed 12 Amps for 105-125VAC or 10 Amps for 210-240VAC. 2.3. Connect Power Mains Connect the supplied power cord to the connector labeled AC Input, and the other end to your AC source. If a power cord with a different terminating plug is required, be sure it is properly rated and meets all the required local electrical standards. Fig. 3 Connect Powered Device Fig. 4 Connect Power Mains Fig. 5 Other Power Cords Sourced Locally 3. LED Indicators The iBoot-EXP had two LED indicators. LED OK - Green PWR - Red OFF No Power Connection from iBoot-G2+ or 12VDC source. The PWR LED is not indicative of the Power outlet status When OK LED ON = Power OFF to the Outlet When OK LED OFF = Not Valid Indication of Power OFF. Power to the outlet may be ON. ON Power to drive the iBoot-EXP is connected. Power Outlet On V130722E iBoot-EXP Page 2 4. Mounting Options iBoot-G2+ is suitable for desktop or shelf mounting. A mounting kit for wall and DIN rail mounting is available. Order part: 1920034 Mounting Kit for iBoot-G2+ G2 Series Remove all cables from the unit prior to installing or removing any mounting hardware. 1920033 Mounting Kit iBoot G2 Series 4.1.1. Installing the Wall Mounting Kit 1. Remove the four mounting screws from the underside of the unit. Do not disassemble the unit. 2. Install the wall mounting ears to the unit using the screws removed in Step 2 4.1.2. DIN Rail Mounting 1. Install the Wall Mounting Kit as shown. 2. Install the DIN rail clips using the four screws provided. 3. The unit is ready for wall mounting. 3. Ready for DIN rail mounting. 4. Use M3 or #4 screws (not included) for attachment to suitable surface V130722E iBoot-EXP Page 3 5. Specifications 5.1. Physical Height Width Depth Weight MTBF Temperature 2.0" 60mm 3.2" 82mm 4.2" 107mm 8.6 oz 244g 540,000 Hours 0 50 degrees C 5.2. AC Input Input Cord Voltage Range Switched Receptacle Capacity IEC 320 C14 16AWGX3C 10A 250 UL/CSA/VDE Rated (1.25mm2X3C) Auto Sensing 105-240 VAC IEC 320 C13 12 A Max at 105-125 VAC, 10 A Max at 210-240 VAC 5.3. Power and Control Connections Four position removable screw terminals. 18AWG maximum. Maximum distance to iBoot-G2+ 330feet/100m using 24AWG wire. +V External + 12VDC input provided by iBoot G2+ I Control Input. Contact closure or open collector transistor circuit only O Status feedback. Open collector circuit. Open = Power On, Grounded = Power Off 5.4. Compliance UL/cUL CE FCC UL60950 Listed I.T.E File No. 188 Directives 89/336/EEC, 92/31/EEC and 93/68/EEC EN 60950: 3rd Edition EN 55022: 1998 Class B Part 15 Class B 6. Important Safety Instructions When using this product, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: .1 Read and understand all instructions. 2. Follow all warnings and marked on the product. 3. Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. 4. Do not use this product in an outdoor environment or near water, for example, near a bath tub, wash bowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool. 5. Do not place this product on an unstable cart, stand, or table. The product may fall, causing serious damage to the product. 6. Slots and openings in this product and the back or bottom are provided for ventilation to protect it from overheating; these openings must not be blocked or covered. The openings should never be blocked by placing the product on the bed, sofa, rug, or other similar surface. This product should never be placed near or over a radiator or heat register. This product should not be placed in a built-in installation unless proper ventilation is provided. 7. This product should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply to your home, consult your dealer or local power company. 8. This product is equipped with a three wire grounding type plug, a plug having a third (grounding) pin. This plug will only fit into a grounding type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the grounding type plug. Do not use a 3-to-2 prong adapter at the receptacle; use of this type adapter may result in risk of electrical shock and/or damage to this product. 9. Do not allow anything to rest on the power cord. Do not locate this product where the cord will be abused by persons walking on it. 10. Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock. 11. Never push objects of any kind into this product through slots as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electrical shock. Never spill liquid of any kind on the product. 12. To reduce the risk of electrical shock, do not disassemble this product, but take it to a qualified serviceman when some service or repair work is required. Opening or removing covers may expose you to dangerous voltages or other risks. Incorrect reassembly can cause electric shock when the appliance is subsequently used. 13. Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions: a) When the power supply cord or plug is damaged or frayed. b) If liquid has been spilled into the product. c) If the product has been exposed to rain or water. d) If the product does not operate normally by following the operating instructions. Adjust only those controls that are covered by the operating instructions because improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to normal operation. e) If the product has been dropped or has been damaged. f) If the product exhibits a distinct change in performance. 14. Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning. 15. Do not use the telephone to report a gas leak in the vicinity of the leak. 16. Do not exceed the maximum output rating of the auxiliary power receptacle Save These Instructions V130722E iBoot-EXP Page 4 7. Technical Support and Warranty Seller warrants this product, if used in accordance with all applicable instructions, to be free from original defects in material and workmanship for a period of Three Years from the date of initial purchase. If the product should prove defective within that period, Seller will repair or replace the product, at its sole discretion. Repairs may be made with new or refurbished components and replacements may be new or refurbished at the Sellers sole discretion. Repaired or replaced units shall be warranteed for the balance of the original warranty, or 90 days, whichever is greater. If Purchased from Dataprobe Inc.; Service under this Warranty is obtained by shipping the product (with all charges prepaid) to the address below. Seller will pay return shipping charges within the United States. Call Dataprobe Technical Service to receive a Return Materials Authorization (RMA) Number prior to sending any equipment back for repair. Include all cables, power supplies, accessories and proof of purchase with shipment. If purchased from an Authorized Dataprobe Reseller; Service under this Warranty is obtained by contacting your Authorized Dataprobe Reseller. THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT, MISUSE, ABUSE OR NEGLECT. SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN. EXCEPT TO THE EXTENT PROHIBITED BY LAW, ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF MERCHANT ABILITY OR FITNESS FOR ANY PURPOSE ARE LIMITED TO THE WARRANTY PERIOD SET FORTH ABOVE; AND THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES. Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from jurisdictions to jurisdiction. WARNING: The individual user should take care to determine prior to use whether this device is suitable, adequate or safe for the use intended. Since individual applications are subject to great variation, the manufacturer makes no representation or warranty as to the suitability of fitness for any specific application. Dataprobe Inc. Technical Support: 201-934-5111 support@dataprobe.com www.dataprobe.com/support.html