RCF EVOX 12 Owner Manual
Product: Professional Active Two-Way Array Sound System
Brand: RCF
Introduction
RCF S.p.A. thanks you for purchasing this product, which has been made to guarantee reliability and high performance.
This manual is to be considered an integral part of this product and must accompany it when it changes ownership as a reference for correct installation and use, as well as for safety precautions. RCF S.p.A. will not assume any responsibility for the incorrect installation and/or use of this product.
Safety Precautions
IMPORTANT: Before connecting and using this product, please read this instruction manual carefully and keep it on hand for future reference.
WARNING: To prevent the risk of fire or electric shock, never expose this product to rain or humidity.
CAUTION: To prevent electric shock hazard, do not connect to mains power supply while grille is removed.
General Safety Precautions
- All precautions, especially safety ones, must be read with special attention as they provide important information.
- To prevent the risk of falling equipment, do not stack multiple units of this product unless this possibility is specified in the user manual.
- RCF S.p.A. strongly recommends this product is only installed by professional qualified installers (or specialised firms) who can ensure correct installation and certify it according to the regulations in force. The entire audio system must comply with the current standards and regulations regarding electrical systems.
- The equipment should be only used on trolleys or supports recommended by the manufacturer. The assembly must be moved with extreme caution. Sudden stops, excessive pushing force, and uneven floors may cause the assembly to overturn.
- Exposure to high sound levels can cause permanent hearing loss. To prevent potentially dangerous exposure, use adequate protection devices such as ear plugs or protective earphones. Consult the technical specifications for maximum sound pressure levels.
- Situate this product far from any heat sources and always ensure adequate air circulation around it.
- Do not overload this product for a long time.
- Never force the control elements (keys, knobs, etc.).
- Do not use solvents, alcohol, benzene or other volatile substances for cleaning the external parts of this product. Use a dry cloth.
- Do not put microphones close and in front of speakers to avoid audio feedback ('Larsen effect').
Power Supply from Mains
- Appliance coupler or PowerCon Connector® is used to disconnect the device from MAIN power and shall remain readily accessible after installation.
- The mains voltage is sufficiently high to involve a risk of electrocution: never install or connect this product when its power cord is plugged in.
- Before powering up, ensure all connections are correct and the mains voltage corresponds to the voltage shown on the rating plate. If not, contact your RCF dealer.
- This is a Class I device and must be connected to a grounded power source.
- Protect the power cord from damage. Ensure it cannot be stepped on or crushed by objects.
- To prevent the risk of electric shock, never open this product as there are no user-serviceable parts inside.
Object and Liquid Precautions
- Make sure that no objects or liquids can get into this product, as this may cause a short circuit. The apparatus shall not be exposed to dripping or splashing. No objects filled with liquid (such as vases) and no naked sources (such as lit candles) should be placed on this apparatus.
Maintenance and Service
- Never attempt operations, modifications, or repairs not expressly described in this manual. Contact an authorized service centre or qualified personnel if: the product does not function correctly, the power cord is damaged, objects or liquids are inside the product, or the product has been subject to a heavy impact.
- If this product is not used for a long period, disconnect its power cord.
- If the product emits strange odours or smoke, switch it off immediately and disconnect its power cord.
- Do not connect this product to any unforeseen equipment or accessories. Do not attempt to hang this product using unsuitable elements.
Notes About Audio Signal Cables
To prevent noise on microphone/line signal cables, use screened cables only and avoid placing them near:
- Equipment producing high-intensity electromagnetic fields.
- Mains cables.
- Loudspeaker lines.
The equipment considered in this manual can be used in electromagnetic environment E1 to E3 as specified on EN 55103-1/2: 2009.
FCC Notes
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when operated in a commercial environment. Operation in a residential area may cause harmful interference, requiring the user to correct it at their own expense.
Modifications: Any modifications not approved by RCF may void the user's authority to operate this equipment.
Description
The EVOX 12 is a portable active sound system, composed of a satellite speaker and a subwoofer. It combines the quality and reliability of RCF transducers with high amplification power.
The EVOX 12 features eight 4.0” full-range transducers in the line source satellite and a deep-sounding 15" woofer in a bass reflex enclosure.
Innovative DSP Processing
EVOX DSP processing is the result of many years of experience in line array design combined with innovative and dedicated algorithms. Thanks to frequency-dependent driver excursion and distortion control, EVOX DSP processing guarantees high output from these compact systems. Dedicated vocal processing is also included for speech reproduction during presentations or conferences.
RCF Technology
EVOX speakers incorporate high-technology RCF transducers. The ultra-compact full-range 4” driver can handle extremely high sound pressure levels and power. The high-excursion woofers extend to the lowest frequencies and offer a quick and precise response up to the crossover point. Specific attention has been dedicated to mid-low frequencies.
Controlled Directivity Pattern
The EVOX array design features a constant horizontal directivity coverage of 90°, offering a perfect listening experience. The vertical array design is progressively shaped to guarantee correct listening from the first row.
Multifunctional Top Handle
The top steel plate integrates the handle and the insert for pole mounting. A rubber hand grip is included for enhanced portability.
Class D Amplification
EVOX systems feature high-power Class D amplifiers. Each system includes a two-way amplifier with DSP-controlled crossover.
Installation
Follow these steps for installation:
- Screw the lower part of the satellite speaker stand (the pole) into the subwoofer insert for pole mounting.
- Loosen the stand bolt, adjust the satellite speaker height from the floor, and tighten the bolt again. Then, insert the satellite speaker onto the stand and aim it correctly.
Subwoofer Rear Panel and Connections
The subwoofer rear panel provides various audio inputs, outputs, and controls.
1/4" TRS Jack Connector
This connector can be used for balanced or unbalanced audio input.
- Balanced Connection: TIP: + HOT, RING: - COLD, SLEEVE: GND
- Unbalanced Connection: TIP: SIGNAL, SLEEVE: GND
XLR Connectors
The panel includes female XLR input and male XLR output connectors.
Balanced Input/Link Panel
This section contains the main audio connections and controls.
- 1/4" TRS Jack Input: Balanced audio input.
- Female XLR Input: Balanced audio input.
- Male XLR Output: Balanced parallel audio output, useful for connecting another amplifier.
Controls and Indicators
- 4. Amplifier Volume Control: Turn clockwise to increase volume, counterclockwise to decrease.
- 5. Input Sensitivity Switch:
- LINE (normal mode): Input sensitivity set to LINE level (+4 dBu), suitable for mixer output.
- MIC: Input sensitivity set to MIC level, suitable for direct connection of a dynamic microphone. Do NOT use this setting when connected to a mixer output.
- 6. FLAT / BOOST Switch:
- FLAT (released): No equalization applied (flat frequency response).
- BOOST (pushed): 'Loudness' equalization, recommended for background music at low volume levels.
- 7. LIMITER LED: Indicates limiter intervention (blinks when clipping point is reached) or excessive input signal (steady lit).
- 8. SIGNAL LED: Indicates signal presence at the audio input.
- 9. STATUS LED: Indicates internal protection intervention due to thermal drift (blinking).
- 10. Amplifier Output: Output to link the satellite speaker.
IMPORTANT: BEFORE TURNING THE AMPLIFIER ON, LINK THE SUBWOOFER AMPLIFIER OUTPUT TO THE SATELLITE SPEAKER INPUT (AS SHOWN IN THE FIGURE)!
Power
- 11. Power Switch: Push to turn ON/OFF the amplifier. Before switching on, check all connections and turn the volume control (4) fully counterclockwise [volume-down].
- 12. Power Cord Input with Fuse:
- For 100-120V~: T 6.3 A L 250V
- For 220-240V~: T 3.15 A L 250V
WARNING: The VDE Power Connector is used to disconnect the system from the power supply network. It shall be easily accessible after installation and during use.
Specifications
| Category | Specification |
|---|---|
| EVOX 12 | |
| ACOUSTICAL | |
| Frequency response | 40 Hz – 20 kHz |
| Maximum sound pressure level | 130 dB |
| Horizontal coverage angle | 90° |
| Vertical coverage angle | 30° |
| Subwoofer transducers | 15" (3.0" voice coil) |
| Satellite transducers | 8 x 4" (1.0" voice coil) |
| AMPLIFIER / DSP | |
| Amplifier power (low frequencies) | 1000 W (peak) |
| Amplifier power (high frequencies) | 400 W (peak) |
| Input sensitivity (LINE) | +4 dBu |
| Crossover frequency | 180 Hz |
| Protections | thermal, RMS |
| Limiter | software limiter |
| Cooling | convective |
| Operating voltage | 115 / 230 V, 50-60 Hz |
| Inrush current | 10.1 A (According to EN 55013-1: 2009) |
| PHYSICAL | |
| Height | 2220 mm (87.4") |
| Width | 410 mm (16.14") |
| Depth | 560 mm (22.05") |
| Net weight | 36.4 kg (80.24 lbs) |
| Cabinet | Birch plywood |
EVOX 12 Size
Contact Information
RCF S.p.A.
Via Raffaello Sanzio, 13
42124 Reggio Emilia - Italy
Tel: +39 0522 274 411
Fax: +39 0522 232 428
E-mail: info@rcf.it