Sentry Wellness System TriGuard Direct RO Replacement Instructions
System Overview and Components
This guide provides instructions for replacing filters and components in the Sentry Wellness System TriGuard Direct RO water filtration system. The system is designed for under-sink installation and ensures purified water.
Diagrammatic Representation:
The system diagram shows the main components:
- A) Bracket: A pre-installed white mounting bracket. [bracket]
- B) Filter Housings: Two housings that hold the filter cartridges, each equipped with O-rings. [filter housings]
- C) FILTER 1: ToxyGuard cartridge. [filter cartridge]
- D) FILTER 2: AlkaGuard cartridge. [filter cartridge]
- E) FILTER 3: BioChemGuard cartridge. [filter cartridge]
- F) Angle Stop Water Flow Valve: Connects to the cold water line. [water valve]
- G) Faucet: The dedicated faucet for purified water. [faucet]
- H) Inlet Tubing: 1/4" tubing for connecting the cold water supply to the system. [tubing]
- I) Outlet Tubing: 1/4" tubing for connecting the system output to the faucet. [tubing]
- J) Mounting Screws: Two screws for securing the bracket. [screws]
- K) Wrench: A tool for removing filter housings. [wrench]
Note: Filters (C, D, E) must be placed into their corresponding housings (B).
Package Contents and Required Tools
Included in the Box (Part Number: CP-SWS-DRR):
- 1 Pre-Installed White Bracket (A)
- 2 Housings with O-Rings (B)
- FILTER 1: ToxyGuard (C)
- FILTER 2: AlkaGuard (D)
- FILTER 3: BioChemGuard (E)
- 1 Angle Stop Water Flow Valve (F)
- 1 Faucet (G)
- 1/4" Tubing for Cold Water-to-Inlet Connection (H)
- 1/4" Tubing for Outlet-to-Faucet Connection (I)
- 2 Screws (J)
- 1 Wrench (K)
Tools Needed (Not Included):
- 1-2 Adjustable Wrenches/Pliers
- Drill with a Philips Head Drill Tip
IMPORTANT SAFETY NOTE: DO NOT REMOVE PLASTIC WRAP FROM FILTERS UNTIL STEP 2.
Installation and Replacement Steps
STEP 1: Mount the System Bracket
Select an installation location, typically under the sink. Use the pre-drilled holes in the white bracket (A) to mark mounting points on the cabinet wall. Drill screws into these marks and securely attach the bracket.
STEP 2: Install Filter Cartridges
Carefully remove the plastic wrap from FILTER 1: TOXYGUARD (C) and insert it into the left-side Housing labeled FILTER 1. Twist the housing securely closed by hand. Repeat this procedure for FILTER 2: ALKAGUARD (D) in the middle FILTER 2 HOUSING and FILTER 3: BIOCHEMGUARD (E) in the right-side FILTER 3 HOUSING. Ensure each filter is placed into its correct, designated housing.
STEP 3: Isolate Cold Water Supply
Turn your main faucet on to the 100% cold setting. Then, shut off the cold-water flow by turning the corresponding water valve clockwise. This valve must remain closed throughout the installation process.
STEP 4: Install Angle Stop Valve
Using an adjustable wrench, disconnect the existing faucet line from the cold-water valve. Place a container under the valve to catch any residual water. Install the Angle Stop Water Flow Valve (F) between the cold water line and the faucet inlet, redirecting water flow to the Sentry Wellness System.
STEP 5: Connect Inlet Tubing
Take the provided 1/4" cold water-to-inlet connection tubing (H). Insert one end firmly into the Angle Stop Water Flow Valve (F) until it is fully seated. Connect the other end to the Inlet Head (FILTER 1 Housing Lid) until it bottoms out. Gently tug on the tubing to confirm a secure connection.
STEP 6: Mount the Dedicated Faucet
Follow the manufacturer's instructions included with your faucet (G) for its proper mounting.
STEP 7: Connect Outlet Tubing and Mount System
Measure and cut the 1/4" outlet-to-faucet tubing (I) to the required length. Insert one end into the dedicated faucet (G) until it bottoms out. Connect the other end to the Outlet Head (FILTER 3 Housing Lid) until it bottoms out. Tug to ensure a tight fit. Finally, place the assembled system onto the bracket screws previously installed in Step 1.
STEP 8: Restore Water Flow and Leak Check
Turn the cold water valve counter-clockwise to restore water flow (ON). Carefully inspect all fitting locations and housing gasket seals for any signs of leaks. If leaks are found, re-seat the tubing, apply additional sealant tape to threads if necessary, or re-tighten/re-install housings as per Step 2. It is advisable to perform leak checks immediately after restoration and again after the first use. Continuous monitoring for one week is recommended.
STEP 9: Purge Filtration Media Dust
Allow the cold water to run through the system for 5-10 minutes. This process purges any excess filtration media dust. If the water appears cloudy or has an unusual taste, continue flushing for an additional 5 minutes or until the water runs clear. Note that reduced water pressure may occur for up to one week as the system fully normalizes.
STEP 10: Annual Filter Replacement and Support
For optimal performance, replace all filters annually. Should you have any questions or require assistance, please contact Sentry H2O.
Support and Additional Resources
For visual guidance, scan the QR Code [QR code] to watch an installation video or visit SentryH2O.com.
Please note: The provided video demonstrates the installation of a 2-Filter DualGuard system. While the process is similar, these written instructions are specific to the 3-Filter TriGuard Sentry Wellness System.