Secop Hermetic Compressors for R600a and R290 Refrigerants
Secop is committed to delivering advanced refrigeration compressors and controls, providing customers tailored sustainable solutions for light commercial, battery-driven, and special cooling applications.
Refrigerants: R600a | R290
Voltage & Frequencies: 208-230V ~ 60Hz, 220-240V ~ 50/60Hz, 220-240V ~ 50Hz, 200-240 V ~ 50/60Hz
Features: ENERGY OPTIMIZED, NATURAL REFRIGERANT
Compressor Specifications - R600a
PLE Series (R600a)
| Compressor Code | Application Cooling | Voltage | Evaporating Temp. [°C] | LBP Rating (-23.3°C / 54.4°C) | MBP Rating (-6.7°C / 54.4°C) | HBP Rating (7.2°C / 54.4°C) | Dimensions (H x W x D) [mm] | Connectors (Suction/Process/Discharge) [mm] |
|---|---|---|---|---|---|---|---|---|
| PLE35K (101H0360) | MBP | 198-254 V, 50 Hz | -35 to 15 | - | Cooling: 106 W, COP: 1.56 | - | 63 x 106 x 133 | 6.2 / 6.2 / 5 |
| TLES4.8KK.3 (102H4579) | LBP | 198-254 V, 50 Hz | -35 to 15 | Cooling: 63 W, COP: 0.91 | Cooling: 88 W, COP: 1.56 | - | - | 6.2 / 6.2 / 5 |
| TLES5.7KK.3 (102H4783) | LBP | 198-254 V, 50 Hz | -35 to 15 | Cooling: 74 W, COP: 1.30 | Cooling: 115 W, COP: 1.30 | - | - | 6.2 / 6.2 / 5 |
| TLES7.5KK.3 (102H4939) | LBP | 198-254 V, 50 Hz | -35 to 15 | Cooling: 125 W, COP: 1.31 | Cooling: 189 W, COP: 1.31 | - | - | 6.2 / 6.2 / 5 |
| TLES5KTK (102H4536) | LBP | 187-254 V, 50 Hz | -35 to 15 | Cooling: 77 W, COP: 1.22 | Cooling: 162 W, COP: 1.78 | - | - | 6.2 / 6.2 / 5 |
| TLES10KTK.3 (102H4050) | LBP | 187-254 V, 50 Hz | -35 to 15 | Cooling: 168 W, COP: 1.36 | Cooling: 249 W, COP: 1.36 | - | - | 6.2 / 6.2 / 5 |
| NLE11KK.4 (105H6952) | LBP | 198-254 V, 50 Hz | -35 to 15 | Cooling: 170 W, COP: 1.51 | Cooling: 252 W, COP: 1.51 | - | - | 6.2 / 6.2 / 5 |
| NLE15KK.4 (105H6968) | LBP | 198-254 V, 50 Hz | -35 to 15 | Cooling: 253 W, COP: 1.53 | Cooling: 374 W, COP: 1.53 | - | - | 6.2 / 6.2 / 5 |
| NLE15MKK (105H6533) | MBP | 187-254 V, 50 Hz * | -35 to 15 | - | Cooling: 202 W, COP: 1.33 | Cooling: 131 W, COP: 1.33 | - | 6.2 / 6.2 / 5 |
| NLX15KK.3 (105H6506) | LBP | 198-254 V, 50 Hz | -35 to 15 | Cooling: 254 W, COP: 1.52 | Cooling: 383 W, COP: 1.52 | - | - | 6.2 / 6.2 / 5 |
| NLU15KK.1 (105H6372) | LBP | 198-254 V, 50 Hz | -35 to 15 | Cooling: 718 W, COP: 2.50 | Cooling: 586 W, COP: 1.49 | Cooling: 852 W, COP: 2.50 | - | 8.2 / 6.2 / 6.2 |
K-Series AA (R600a)
| Compressor Code | Application Cooling | Voltage | Evaporating Temp. [°C] | LBP Rating (-23.3°C / 54.4°C) | MBP Rating (-6.7°C / 54.4°C) | HBP Rating (7.2°C / 54.4°C) | Dimensions (H x W x D) [mm] | Connectors (Suction/Process/Discharge) [mm] |
|---|---|---|---|---|---|---|---|---|
| HKK80AA (CDO00041) | LBP | 187-264 V, 50 Hz | -35 to 15 | Cooling: 145 W, COP: 1.71 | Cooling: 224 W, COP: 2.29 | - | - | 6.15 / 6.00 / 5.15 |
| HKK12AA (CDO00043) | LBP | 187-264 V, 50 Hz | -35 to 15 | Cooling: 291 W, COP: 1.80 | Cooling: 428 W, COP: 2.25 | - | - | 6.15 / 6.00 / 5.15 |
| HMK95AA (CDO00164) | LBP | 187-264 V, 50 Hz | -35 to 15 | Cooling: 252 W, COP: 1.53 | Cooling: 381 W, COP: 2.01 | - | - | 6.15 / 6.00 / 5.15 |
| HTK80AA (CDO00036) | LBP | 187-264 V, 50 Hz | -35 to 15 | Cooling: 207 W, COP: 1.61 | Cooling: 316 W, COP: 2.19 | - | - | 6.15 / 6.00 / 5.15 |
| HXK80AA (CDO00096) | LBP | 187-264 V, 50 Hz | -35 to 15 | Cooling: 210 W, COP: 1.90 | Cooling: 316 W, COP: 2.38 | - | - | 6.15 / 6.00 / 5.15 |
| HZK95AA (CDO00077) | LBP | 187-264 V, 50 Hz | -35 to 15 | Cooling: 254 W, COP: 1.99 | Cooling: 376 W, COP: 2.54 | - | - | 6.15 / 6.00 / 5.15 |
K-Series AT (R600a)
| Compressor Code | Application Cooling | Voltage | Evaporating Temp. [°C] | LBP Rating (-23.3°C / 54.4°C) | MBP Rating (-6.7°C / 54.4°C) | HBP Rating (7.2°C / 54.4°C) | Dimensions (H x W x D) [mm] | Connectors (Suction/Process/Discharge) [mm] |
|---|---|---|---|---|---|---|---|---|
| HXK80AT (CDO00135) | LBP | 170-264 V, 50 Hz * | -35 to 15 | Cooling: 208 W, COP: 1.75 | - | - | - | 6.15 / 6.00 / 5.15 |
| HXK12AT (CDO00219) | LBP | 170-264 V, 50 Hz * | -35 to 15 | Cooling: 295 W, COP: 1.73 | - | - | - | 6.15 / 6.00 / 5.15 |
Compressor Specifications - R290
TL / TLES / DLE Series (R290)
| Compressor Code | Application Cooling | Voltage | Evaporating Temp. [°C] | LBP Rating (-23.3°C / 54.4°C) | MBP Rating (-6.7°C / 54.4°C) | HBP Rating (7.2°C / 54.4°C) | Dimensions (H x W x D) [mm] | Connectors (Suction/Process/Discharge) [mm] |
|---|---|---|---|---|---|---|---|---|
| TL5CN (102H4590) | L/MBP | 198-254 V, 50 Hz | -35 to 15 | Cooling: 249 W, COP: 1.18 | Cooling: 161 W, COP: 1.07 | Cooling: 208 W, COP: 1.38 | - | 6.2 / 6.2 / 5 |
| DLE5.7CN (102H4653) | L/MBP | 198-254 V, 50 Hz | -35 to 15 | Cooling: 436 W, COP: 1.18 | Cooling: 296 W, COP: 1.18 | Cooling: 367 W, COP: 1.53 | - | 6.2 / 6.2 / 5 |
| NLE11CNL (105H6174) | LBP | 198-254 V, 50 Hz | -35 to 15 | Cooling: 603 W, COP: 1.53 | Cooling: 415 W, COP: 1.53 | Cooling: 511 W, COP: 2.60 | - | 8.2 / 6.2 / 6.2 |
| NLU8.8DN (105H6085) | M/HBP | 187-254 V, 50 Hz | -35 to 15 | - | Cooling: 765 W, COP: 1.47 | Cooling: 511 W, COP: 2.60 | - | 8.2 / 6.2 / 6.2 |
| SC15CNX (104H8565) | L/MBP | 198-254 V, 50 Hz | -35 to 15 | Cooling: 853 W, COP: 1.27 | Cooling: 547 W, COP: 1.27 | Cooling: 693 W, COP: 2.81 | - | 8.2 / 6.2 / 6.2 |
| SCE18CNLX (104H8848) | LBP | 198-254 V, 50 Hz | -35 to 15 | Cooling: 1166 W, COP: 1.58 | Cooling: 795 W, COP: 1.58 | Cooling: 1210 W, COP: 3.09 | - | 10.2 / 6.2 / 6.2 |
Series Overview
- PLE Series: Standard compressors for R600a.
- TL / TLES Series: Hermetic compressors for R600a and R290.
- DLE Series: Hermetic compressors for R290.
- K-Series (HKK, HMK, HTK, HXK, HZK): Hermetic compressors for R600a.
- N-Series (NLX, NLU, NLE): Hermetic compressors for R600a and R290.
- SC / SCE Series: Hermetic compressors for R290.
Electrical Equipment & Motor Systems
Motor Types:
- RSIR: Resistant Start Induction Run
- RSCR: Resistant Start Capacitor Run
- CSIR: Capacitor Start Induction Run
- CSR: Capacitor Start Run
Starting Devices:
- LST (Low Starting Torque): Used with capillary tube control and pressure equalizing. PTC starting device requires 5 minutes cooling before each start.
- HST (High Starting Torque): Consists of relay and starting capacitor, used for expansion valve control or capillary tube control without pressure equalizing.
- ePTC (Electronically controlled PTC): Compressor restart possible after a few seconds, reduced operational wattage loss, PTC protection screen not needed.
Compressor Cooling:
- S = Static cooling (normally sufficient)
- O = Oil cooling
- F1 = Fan cooling 1.5 m/s (compressor compartment temp. equal to ambient)
- F2 = Fan cooling 3.0 m/s necessary
Wiring Diagram Description (Example for LST - RSCR):
The diagram shows connections for a motor protector, thermostat, run capacitor, starting capacitor, starting relay, and terminal board. Wires are color-coded: Yellow/Green for Earthing, Black for Start, Brown for Common, Blue or Grey for Run. Main winding and start winding are indicated.
Note on EN 60335-2-34: For K-Series (excluding HMK), protection screen 103N0476 must be applied to the PTC starting device.
Mounting Accessories
| Mounting Type | Code Number | Bolt/Pin Dimension | Comp. Base Hole | Parts List (4 pcs. per compressor needed) |
|---|---|---|---|---|
| Bolt joint | 118-1917 | M6 metric | 16 mm | I (Sleeve, Washer, Bolt M6 x 25mm, Nut M6, Rubber grommet 16mm) |
| Bolt joint | 118-1918 | M6 metric | 16 mm | II (Sleeve, Washer, Bolt M8 x 40mm, Nut M8, Rubber grommet 19mm) |
| Bolt joint | 107B9150 | M8 metric | 19 mm | III (Sleeve, Washer, Bolt 1/4 x 1 inch, Nut 1/4 inch, Rubber grommet 16mm) |
| Snap-on | 118-1947 | ~ 7.3 mm | 16 mm | IV (Sleeve, Washer, Bolt 1/4 x 1 1/4 inch, Nut 1/4 inch, Rubber grommet 19mm) |
| Snap-on | 118-1919 | ~ 7.3 mm | 16 mm | V (Steel pin, Washer, Clip, Rubber Grommet 16mm) |
Packaging Types: Single pack or Industrial pack available for various compressor series.
Safety Information: Flammable Refrigerants
Warning: Natural refrigerants R600a (isobutane) and R290 (propane) are hydrocarbons and are flammable.
Usage Requirements: Only allowed for use in appliances that meet the requirements set out in the latest revision of EN/IEC 60335-2-34.
Precautions:
- Do not use near an open fire.
- Refrigeration systems must be opened with a tube cutter.
- Service staff must be properly trained in handling flammable refrigerants, including tools, transportation, and relevant regulations/safety precautions.
Identification: Secop compressors using R600a and R290 are equipped with a yellow warning label.
Secop Group: Global Presence & Commitment
Secop is the expert for advanced hermetic compressor technologies and cooling solutions in commercial refrigeration. They develop high-performance stationary and mobile cooling solutions for leading international commercial refrigeration manufacturers.
Global Footprint:
- Locations: Laboratories in Austria, Germany, Slovakia, China, US, and Turkey. Sales and R&D centers in Flensburg, Turin, Gleisdorf, Zlaté Moravce, Tianjin, and Atlanta.
- Expertise: 180 R&D engineers and technicians.
- Innovation: 440 patents globally.
- Support: Customer support in 50+ countries.
Corporate Responsibility: Since 2011, Secop has been committed to the UN Global Compact principles regarding human rights, labor, the environment, and anti-corruption.