Secop Hermetic Compressors for R600a and R290 Refrigerants

Secop is committed to delivering advanced refrigeration compressors and controls, providing customers tailored sustainable solutions for light commercial, battery-driven, and special cooling applications.

Refrigerants: R600a | R290

Voltage & Frequencies: 208-230V ~ 60Hz, 220-240V ~ 50/60Hz, 220-240V ~ 50Hz, 200-240 V ~ 50/60Hz

Features: ENERGY OPTIMIZED, NATURAL REFRIGERANT

www.secop.com

Compressor Specifications - R600a

PLE Series (R600a)

Compressor Code Application Cooling Voltage Evaporating Temp. [°C] LBP Rating (-23.3°C / 54.4°C) MBP Rating (-6.7°C / 54.4°C) HBP Rating (7.2°C / 54.4°C) Dimensions (H x W x D) [mm] Connectors (Suction/Process/Discharge) [mm]
PLE35K (101H0360) MBP 198-254 V, 50 Hz -35 to 15 - Cooling: 106 W, COP: 1.56 - 63 x 106 x 133 6.2 / 6.2 / 5
TLES4.8KK.3 (102H4579) LBP 198-254 V, 50 Hz -35 to 15 Cooling: 63 W, COP: 0.91 Cooling: 88 W, COP: 1.56 - - 6.2 / 6.2 / 5
TLES5.7KK.3 (102H4783) LBP 198-254 V, 50 Hz -35 to 15 Cooling: 74 W, COP: 1.30 Cooling: 115 W, COP: 1.30 - - 6.2 / 6.2 / 5
TLES7.5KK.3 (102H4939) LBP 198-254 V, 50 Hz -35 to 15 Cooling: 125 W, COP: 1.31 Cooling: 189 W, COP: 1.31 - - 6.2 / 6.2 / 5
TLES5KTK (102H4536) LBP 187-254 V, 50 Hz -35 to 15 Cooling: 77 W, COP: 1.22 Cooling: 162 W, COP: 1.78 - - 6.2 / 6.2 / 5
TLES10KTK.3 (102H4050) LBP 187-254 V, 50 Hz -35 to 15 Cooling: 168 W, COP: 1.36 Cooling: 249 W, COP: 1.36 - - 6.2 / 6.2 / 5
NLE11KK.4 (105H6952) LBP 198-254 V, 50 Hz -35 to 15 Cooling: 170 W, COP: 1.51 Cooling: 252 W, COP: 1.51 - - 6.2 / 6.2 / 5
NLE15KK.4 (105H6968) LBP 198-254 V, 50 Hz -35 to 15 Cooling: 253 W, COP: 1.53 Cooling: 374 W, COP: 1.53 - - 6.2 / 6.2 / 5
NLE15MKK (105H6533) MBP 187-254 V, 50 Hz * -35 to 15 - Cooling: 202 W, COP: 1.33 Cooling: 131 W, COP: 1.33 - 6.2 / 6.2 / 5
NLX15KK.3 (105H6506) LBP 198-254 V, 50 Hz -35 to 15 Cooling: 254 W, COP: 1.52 Cooling: 383 W, COP: 1.52 - - 6.2 / 6.2 / 5
NLU15KK.1 (105H6372) LBP 198-254 V, 50 Hz -35 to 15 Cooling: 718 W, COP: 2.50 Cooling: 586 W, COP: 1.49 Cooling: 852 W, COP: 2.50 - 8.2 / 6.2 / 6.2

K-Series AA (R600a)

Compressor Code Application Cooling Voltage Evaporating Temp. [°C] LBP Rating (-23.3°C / 54.4°C) MBP Rating (-6.7°C / 54.4°C) HBP Rating (7.2°C / 54.4°C) Dimensions (H x W x D) [mm] Connectors (Suction/Process/Discharge) [mm]
HKK80AA (CDO00041) LBP 187-264 V, 50 Hz -35 to 15 Cooling: 145 W, COP: 1.71 Cooling: 224 W, COP: 2.29 - - 6.15 / 6.00 / 5.15
HKK12AA (CDO00043) LBP 187-264 V, 50 Hz -35 to 15 Cooling: 291 W, COP: 1.80 Cooling: 428 W, COP: 2.25 - - 6.15 / 6.00 / 5.15
HMK95AA (CDO00164) LBP 187-264 V, 50 Hz -35 to 15 Cooling: 252 W, COP: 1.53 Cooling: 381 W, COP: 2.01 - - 6.15 / 6.00 / 5.15
HTK80AA (CDO00036) LBP 187-264 V, 50 Hz -35 to 15 Cooling: 207 W, COP: 1.61 Cooling: 316 W, COP: 2.19 - - 6.15 / 6.00 / 5.15
HXK80AA (CDO00096) LBP 187-264 V, 50 Hz -35 to 15 Cooling: 210 W, COP: 1.90 Cooling: 316 W, COP: 2.38 - - 6.15 / 6.00 / 5.15
HZK95AA (CDO00077) LBP 187-264 V, 50 Hz -35 to 15 Cooling: 254 W, COP: 1.99 Cooling: 376 W, COP: 2.54 - - 6.15 / 6.00 / 5.15

K-Series AT (R600a)

Compressor Code Application Cooling Voltage Evaporating Temp. [°C] LBP Rating (-23.3°C / 54.4°C) MBP Rating (-6.7°C / 54.4°C) HBP Rating (7.2°C / 54.4°C) Dimensions (H x W x D) [mm] Connectors (Suction/Process/Discharge) [mm]
HXK80AT (CDO00135) LBP 170-264 V, 50 Hz * -35 to 15 Cooling: 208 W, COP: 1.75 - - - 6.15 / 6.00 / 5.15
HXK12AT (CDO00219) LBP 170-264 V, 50 Hz * -35 to 15 Cooling: 295 W, COP: 1.73 - - - 6.15 / 6.00 / 5.15

Compressor Specifications - R290

TL / TLES / DLE Series (R290)

Compressor Code Application Cooling Voltage Evaporating Temp. [°C] LBP Rating (-23.3°C / 54.4°C) MBP Rating (-6.7°C / 54.4°C) HBP Rating (7.2°C / 54.4°C) Dimensions (H x W x D) [mm] Connectors (Suction/Process/Discharge) [mm]
TL5CN (102H4590) L/MBP 198-254 V, 50 Hz -35 to 15 Cooling: 249 W, COP: 1.18 Cooling: 161 W, COP: 1.07 Cooling: 208 W, COP: 1.38 - 6.2 / 6.2 / 5
DLE5.7CN (102H4653) L/MBP 198-254 V, 50 Hz -35 to 15 Cooling: 436 W, COP: 1.18 Cooling: 296 W, COP: 1.18 Cooling: 367 W, COP: 1.53 - 6.2 / 6.2 / 5
NLE11CNL (105H6174) LBP 198-254 V, 50 Hz -35 to 15 Cooling: 603 W, COP: 1.53 Cooling: 415 W, COP: 1.53 Cooling: 511 W, COP: 2.60 - 8.2 / 6.2 / 6.2
NLU8.8DN (105H6085) M/HBP 187-254 V, 50 Hz -35 to 15 - Cooling: 765 W, COP: 1.47 Cooling: 511 W, COP: 2.60 - 8.2 / 6.2 / 6.2
SC15CNX (104H8565) L/MBP 198-254 V, 50 Hz -35 to 15 Cooling: 853 W, COP: 1.27 Cooling: 547 W, COP: 1.27 Cooling: 693 W, COP: 2.81 - 8.2 / 6.2 / 6.2
SCE18CNLX (104H8848) LBP 198-254 V, 50 Hz -35 to 15 Cooling: 1166 W, COP: 1.58 Cooling: 795 W, COP: 1.58 Cooling: 1210 W, COP: 3.09 - 10.2 / 6.2 / 6.2

Series Overview

  • PLE Series: Standard compressors for R600a.
  • TL / TLES Series: Hermetic compressors for R600a and R290.
  • DLE Series: Hermetic compressors for R290.
  • K-Series (HKK, HMK, HTK, HXK, HZK): Hermetic compressors for R600a.
  • N-Series (NLX, NLU, NLE): Hermetic compressors for R600a and R290.
  • SC / SCE Series: Hermetic compressors for R290.

Electrical Equipment & Motor Systems

Motor Types:

  • RSIR: Resistant Start Induction Run
  • RSCR: Resistant Start Capacitor Run
  • CSIR: Capacitor Start Induction Run
  • CSR: Capacitor Start Run

Starting Devices:

  • LST (Low Starting Torque): Used with capillary tube control and pressure equalizing. PTC starting device requires 5 minutes cooling before each start.
  • HST (High Starting Torque): Consists of relay and starting capacitor, used for expansion valve control or capillary tube control without pressure equalizing.
  • ePTC (Electronically controlled PTC): Compressor restart possible after a few seconds, reduced operational wattage loss, PTC protection screen not needed.

Compressor Cooling:

  • S = Static cooling (normally sufficient)
  • O = Oil cooling
  • F1 = Fan cooling 1.5 m/s (compressor compartment temp. equal to ambient)
  • F2 = Fan cooling 3.0 m/s necessary

Wiring Diagram Description (Example for LST - RSCR):

The diagram shows connections for a motor protector, thermostat, run capacitor, starting capacitor, starting relay, and terminal board. Wires are color-coded: Yellow/Green for Earthing, Black for Start, Brown for Common, Blue or Grey for Run. Main winding and start winding are indicated.

Note on EN 60335-2-34: For K-Series (excluding HMK), protection screen 103N0476 must be applied to the PTC starting device.

Mounting Accessories

Mounting Type Code Number Bolt/Pin Dimension Comp. Base Hole Parts List (4 pcs. per compressor needed)
Bolt joint 118-1917 M6 metric 16 mm I (Sleeve, Washer, Bolt M6 x 25mm, Nut M6, Rubber grommet 16mm)
Bolt joint 118-1918 M6 metric 16 mm II (Sleeve, Washer, Bolt M8 x 40mm, Nut M8, Rubber grommet 19mm)
Bolt joint 107B9150 M8 metric 19 mm III (Sleeve, Washer, Bolt 1/4 x 1 inch, Nut 1/4 inch, Rubber grommet 16mm)
Snap-on 118-1947 ~ 7.3 mm 16 mm IV (Sleeve, Washer, Bolt 1/4 x 1 1/4 inch, Nut 1/4 inch, Rubber grommet 19mm)
Snap-on 118-1919 ~ 7.3 mm 16 mm V (Steel pin, Washer, Clip, Rubber Grommet 16mm)

Packaging Types: Single pack or Industrial pack available for various compressor series.

Safety Information: Flammable Refrigerants

Warning: Natural refrigerants R600a (isobutane) and R290 (propane) are hydrocarbons and are flammable.

Usage Requirements: Only allowed for use in appliances that meet the requirements set out in the latest revision of EN/IEC 60335-2-34.

Precautions:

  • Do not use near an open fire.
  • Refrigeration systems must be opened with a tube cutter.
  • Service staff must be properly trained in handling flammable refrigerants, including tools, transportation, and relevant regulations/safety precautions.

Identification: Secop compressors using R600a and R290 are equipped with a yellow warning label.

Secop Group: Global Presence & Commitment

Secop is the expert for advanced hermetic compressor technologies and cooling solutions in commercial refrigeration. They develop high-performance stationary and mobile cooling solutions for leading international commercial refrigeration manufacturers.

Global Footprint:

  • Locations: Laboratories in Austria, Germany, Slovakia, China, US, and Turkey. Sales and R&D centers in Flensburg, Turin, Gleisdorf, Zlaté Moravce, Tianjin, and Atlanta.
  • Expertise: 180 R&D engineers and technicians.
  • Innovation: 440 patents globally.
  • Support: Customer support in 50+ countries.

Corporate Responsibility: Since 2011, Secop has been committed to the UN Global Compact principles regarding human rights, labor, the environment, and anti-corruption.

Secop GmbH
Mads-Clausen-Str. 7
24939 Flensburg, Germany
Tel: +49 461 4941 0
www.secop.com

Secop accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. All trademarks are the property of their respective companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved.

Produced by Secop | May 2021

Original Document