Instruction Manual for neptronic models including: CMMB100 Dual Mini Input Communication Module, CMMB100, Dual Mini Input Communication Module, Mini Input Communication Module, Input Communication Module, Communication Module, Module
Controls ation
Controls BACnet I/O Board
File Info : application/pdf, 12 Pages, 485.23KB
DocumentDocumentDual Mini Input Communication Module Specification and Installation Instructions Models CMMB100 Description The CMMB extends your BACnet or Modbus network when your application requires additional inputs on a physical controller. Combining the 8 inputs of the CMMB with your Building Automation System provides simple expansion of a new or existing controller and reduces unnecessary costs of additional components. Features Power & Communication · 24Vac or 24Vdc supply · BACnet® MS/TP or Modbus communication port (selectable) Inputs · 8 universal inputs Installation · LED status indication of each input · DIN rail mounting · Removable, non-strip, raising clamp terminals · Removable see-through panel for easy access to DIP switches CMMB100 Network Communication · BACnet® MS/TP or Modbus communication port (selectable via DIP switch) · Select MAC address via DIP switch or via network BACnet® · MS/TP @ 9600, 19200, 38400 or 76800 bps · Automatic baud rate detection · Automatic device instance configuration · Copy & broadcast configuration to other CMMB modules Modbus · Modbus @ 9600, 19200, 38400 or 57600 bps · RTU Slave, 8 bits (configurable parity and stop bits) · Connects to any Modbus master Technical Specifications Specifications Input Voltage Consumption Universal Inputs BACnet Modbus Communication Connections Electrical Connections Operational Temperature Storage Temperature Relative Humidity Weight Dimensions A = 3.18" / 81 mm B = 4.93" / 125 mm C = 2.27" / 58 mm CMMB100 24 Vac or 24 Vdc 3VA (175mA @ 24 Vac) 8 [0.00-10.00Vdc, 10K/20K/30K, on/off (dry contact), 4.00-20.00mA] / 12b hardware resolution with oversampling BACnet® MS/TP @ 9600, 19200, 38400 or 76800 bps (BAS-C) Modbus RTU slave @ 9600, 19200, 38400 or 57600. Selectable parity and stop bit configuration: · No parity, 2 stop bit · Even parity, 1 stop bit · Odd parity, 1 stop bit 24 AWG twisted-shield cable (Belden 9841 or equivalent) 0.8 mm2 [18 AWG] minimum 0ºC to 50ºC [32ºF to 122ºF] -30ºC to 50ºC [-22ºF to 122ºF] 5 a 95% non condensed 0.2 kg [0.4 lb] A C B CMMB100-V1.07-240305-ESA Page | 1 Dual Mini Input Communication Module Specification and Installation Instructions Connections and Configurations Please note that all jumper settings must also be set to the same value through BACnet. Some additional configurations are only available through BACnet (see Network Conditions on page 3). Network | DS2 4 OF F ON Mode BACnet* Modbus 3 Mode Options If BACnet OF F Auto Detect* ON Manual (see DS2-1 & DS2-2) If Modbus OF F Config via Modbus Register ON No parity, 2 stop bits * default setting Baud Rate | DS2 1 2 Result OFF OFF 9,600 ON OFF 19,200 OFF ON 38,400 ON ON BACnet: 76,800 Modbus: 57,600 MAC Address | DS1 The 8 DIP switches represent a binary logic to calculate the MAC address. Default = all OFF BACnet all OFF = 0 Modbus all OFF = 1 End of Line | JP5 None* 120 ohms * default setting Network Port | TB4 A+: BACnet/Modbus A+ B-: BACnet/Modbus BCOM: Common Universal Inputs | TB5-6 ** Selectable ** AI1: Universal Input 1 COM: Common AI2: Universal Input 2 AI3: Universal Input 3 COM: Common AI4: Universal Input 4 AI1-AI4 Signal | JP6-JP9 I = 4-20mA T *= Thermistor / on-off V= 0-10Vdc * default setting A+ BCOM AI2 TX RX JP5 AI1 AI1 COM AI2 AI3 COM AI4 AI3 AI4 STATUS POWER ON 1 2 3 4 DS2 ON 1 2 3 4 5 6 7 8 DS1 24V COM COM AI8 AI7 AI8 COM AI7 AI6 COM AI5 AI5 AI6 Voltage Input | TB1 ** 175mA max ** 24V: 24 Vac or 24 Vdc COM: Common COM: Common Universal Inputs | TB2-3 ** Selectable ** AI8: Universal Input 8 COM: Common AI7: Universal Input 7 AI6: Universal Input 6 COM: Common AI5: Universal Input 5 AI5-AI8 Signal | JP1-JP4 V = 0-10Vdc T*= Thermistor / on-off I = 4-20mA * default setting LEDs Power On Off = Input voltage normal = No power Status Flashing = Normal operation (watchdog) RX/TX (BACnet) Flashing = Receiving (RX) and/or transmitting (TX) data. RX/TX (Modbus) Flashing = Receiving (RX) and/or transmitting (TX) data. Input Status On = Input on Off = Input off Flashing = Input not connected (thermistor setting only) Analog = When Universal Inputs are set to analog values (Vdc, mA, or Thermistor); the LED intensity corresponds to the input value. For example: At 10Vdc, the LED will be fully on. At 5Vdc, the LED will be at 50% intensity. At 0 Vdc, the LED will be off. www.neptronic.com Page | 2 Dual Mini Input Communication Module Specification and Installation Instructions MAC Address DIP Switch (DS1) MAC address for BACnet and Modbus communication, are selectable by DIP switch DS1 using binary logic. BACnet · Highest MAC address is 254. · Default is all switches OFF = MAC address 0 · If you do not change device instance in program mode, it will be automatically modified according to the MAC address. MAC Address 0 1 2 3 4 ... 126 ... 254 DS.1 = 1 OFF ON OFF ON OFF ... OFF ... OFF DS.2 = 2 OFF OFF ON ON OFF ... ON ... ON DS.3 = 4 OFF OFF OFF OFF ON ... ON ... ON DS.4 = 8 OFF OFF OFF OFF OFF ... ON ... ON DS.5 = 16 OFF OFF OFF OFF OFF ... ON ... ON DS.6 = 32 OFF OFF OFF OFF OFF ... ON ... ON DS.7 = 64 OFF OFF OFF OFF OFF ... ON ... ON DS.8 = 128 OFF OFF OFF OFF OFF ... OFF ... ON Default Device Instance 153000 153001 153002 153003 153004 ... 153126 ... 153254 Modbus · Highest MAC address is 247. · Default is all switches OFF = MAC address 1 · MAC address is binary value +1 · There is no device instance for Modbus. MAC Address 0+1 = 1 1+1 = 2 2+1 = 3 3+1 = 4 4+1 = 5 ... 126+1 = 127 ... 246+1 = 247 DS.1 = 1 OFF ON OFF ON OFF ... OFF ... OFF DS.2 = 2 OFF OFF ON ON OFF ... ON ... ON DS.3 = 4 OFF OFF OFF OFF ON ... ON ... ON DS.4 = 8 OFF OFF OFF OFF OFF ... ON ... OFF DS.5 = 16 OFF OFF OFF OFF OFF ... ON ... ON DS.6 = 32 OFF OFF OFF OFF OFF ... ON ... ON DS.7 = 64 OFF OFF OFF OFF OFF ... ON ... ON DS.8 = 128 OFF OFF OFF OFF OFF ... OFF ... ON Network Conditions Please note that all jumper settings must also be set to the same value through BACnet or Modbus. The following is a list of conditions and additional BACnet or Modbus objects. Universal Inputs (AI1-AI8) · For temperature thermistor reading: with the jumper set to Thermistor, set the AI input type to 10K_TypeG, 10K_Type3A1, 10K_Type4A1, 10K_NTC, 20K_Type6A1 or 30K_Type6A1. · For on/off contact input reading: with the hardware jumper set to Thermistor, set the AI input type to Digital_Input. The polarity can also be set to direct or reverse. For example, in Reverse an "on" signal would be recognized as an "off" signal. · For analog 0-10 Vdc input reading: with the hardware jumper set to 0-10 Vdc, set the AI input type to 0_10V. Pulse Counting Feature The pulse counting feature enables counting the number of pulses detected by the inputs. · When an active edge is detected, the Pulse Count is incremented by 1 up to the Prescaler value. When the Prescaler value is reached, the Accumulator is incremented by 1 and the Pulse Count is reset to 0. · A value that is higher than 80% of the input's saturation confirms a high level. A value that is lower than 20% of the input's saturation confirms a low level. · The maximum frequency is 100Hz and the minimum pulse length is 5ms/50%D.C. www.neptronic.com Page | 3 BACnet Objects Table ID1 Name AI.1 UniversalInput1 AI.2 UniversalInput2 AI.3 UniversalInput3 AI.4 UniversalInput4 AI.5 UniversalInput5 AI.6 UniversalInput6 AI.7 UniversalInput7 AI.8 AV.1 AV.2 AV.3 AV.4 AV.5 AV.6 AV.7 AV.8 AV.11 AV.12 AV.13 AV.14 AV.15 AV.16 AV.17 AV.18 AV.226 AV.227 UniversalInput8 UI1PulseCount UI2PulseCount UI3PulseCount UI4PulseCount UI5PulseCount UI6PulseCount UI7PulseCount UI8PulseCount UI1Accumulator UI2Accumulator UI3Accumulator UI4Accumulator UI5Accumulator UI6Accumulator UI7Accumulator UI8Accumulator UniversalInput1Offset UniversalInput2Offset Dual Mini Input Communication Module Specification and Installation Instructions Description Universal input 1 mode selected by MSV.1 Universal input 2 mode selected by MSV.12 Universal input 3 mode selected by MSV.15 Universal input 4 mode selected by MSV.48 Universal input 5 mode selected by MSV.57 Universal input 6 mode selected by MSV.58 Universal input 7 mode selected by MSV.59 Universal input 8 mode selected by MSV.60 Universal input 1 pulse count. Universal input 2 pulse count. Universal input 3 pulse count. Universal input 4 pulse count. Universal input 5 pulse count. Universal input 6 pulse count. Universal input 7 pulse count. Universal input 8 pulse count. Universal input 1 pulse counter rollovers. Universal input 2 pulse counter rollovers. Universal input 3 pulse counter rollovers. Universal input 4 pulse counter rollovers. Universal input 5 pulse counter rollovers. Universal input 6 pulse counter rollovers. Universal input 7 pulse counter rollovers. Universal input 8 pulse counter rollovers. Universal input 1 offset Universal input 2 offset Writable? Out of service Out of service Out of service Out of service Out of service Out of service Out of service Out of service Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Notes (* = default) ( = only when UniversalInputxFunction is set to 10K_Type3/G) 0 to 10Volt or -40 to 100ºC (150ºC) or -40 to 212ºF (302ºF) or 4 to 20mA or 0 to 1 Resolution: 0.01Volt or 0.01ºC/0.02ºF or 0.01mA or 1 0 to 10Volt or -40 to 100ºC (150ºC) or -40 to 212ºF (302ºF) or 4 to 20mA or 0 to 1 Resolution: 0.01Volt or 0.01ºC/0.02ºF or 0.01mA or 1 0 to 10Volt or -40 to 100ºC (150ºC) or -40 to 212ºF (302ºF) or 4 to 20mA or 0 to 1 Resolution: 0.01Volt or 0.01ºC/0.02ºF or 0.01mA or 1 0 to 10Volt or -40 to 100ºC (150ºC) or -40 to 212ºF (302ºF) or 4 to 20mA or 0 to 1 Resolution: 0.01Volt or 0.01ºC/0.02ºF or 0.01mA or 1 0 to 10Volt or -40 to 100ºC (150ºC) or -40 to 212ºF (302ºF) or 4 to 20mA or 0 to 1 Resolution: 0.01Volt or 0.01ºC/0.02ºF or 0.01mA or 1 0 to 10Volt or -40 to 100ºC (150ºC) or -40 to 212ºF (302ºF) or 4 to 20mA or 0 to 1 Resolution: 0.01Volt or 0.01ºC/0.02ºF or 0.01mA or 1 0 to 10Volt or -40 to 100ºC (150ºC) or -40 to 212ºF (302ºF) or 4 to 20mA or 0 to 1 Resolution: 0.01Volt or 0.01ºC/0.02ºF or 0.01mA or 1 0 to 10Volt or -40 to 100ºC (150ºC) or -40 to 212ºF (302ºF) or 4 to 20mA or 0 to 1 Resolution: 0.01Volt or 0.01ºC/0.02ºF or 0.01mA or 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 0 to 16777216, Resolution: 1 Present Value 0 to 16777216, Resolution: 1 Present Value 0 to 16777216, Resolution: 1 Present Value 0 to 16777216, Resolution: 1 Present Value 0 to 16777216, Resolution: 1 Present Value 0 to 16777216, Resolution: 1 Present Value 0 to 16777216, Resolution: 1 Present Value 0 to 16777216, Resolution: 1 Present Value 0 to 16777216, Resolution: 1 Present Value Present Value -5.00 to 5.00 ºC/ºF/Volt/mA (default 0*) Resolution: 0.1 ºC/ºF/Volt/mA -5.00 to 5.00 ºC/ºF/Volt/mA (default 0*) Resolution: 0.1 ºC/ºF/Volt/mA 1 ID is equal to ObjectType.Instance www.neptronic.com Page | 4 ID1 AV.228 AV.229 AV.230 AV.231 AV.232 AV.233 AV.468 AV.469 Name UniversalInput3Offset UniversalInput4Offset UniversalInput5Offset UniversalInput6Offset UniversalInput7Offset UniversalInput8Offset CopyCfgStartAdd CopyCfgEndAdd AV.470 CopyCfgResult2 AV.509 AV.510 AV.511 AV.512 AV.513 AV.514 AV.515 AV.516 BV.93 BV.94 BV.95 BV.96 BV.97 BV.98 BV.99 BV.100 UI1PulsePrescaler UI2PulsePrescaler UI3PulsePrescaler UI4PulsePrescaler UI5PulsePrescaler UI6PulsePrescaler UI7PulsePrescaler UI8PulsePrescaler UI1_DI_Polarity UI2_DI_Polarity UI3_DI_Polarity UI4_DI_Polarity UI5_DI_Polarity UI6_DI_Polarity UI7_DI_Polarity UI8_DI_Polarity BV.101 CopyCfgExecute BV.102 SystemUnit Dual Mini Input Communication Module Specification and Installation Instructions Description Universal input 3 offset Universal input 4 offset Universal input 5 offset Universal input 6 offset Universal input 7 offset Universal input 8 offset Copy configuration start address Copy configuration end address Copy configuration result Universal input 1 pulse counter rollover threshold. Universal input 2 pulse counter rollover threshold. Universal input 3 pulse counter rollover threshold. Universal input 4 pulse counter rollover threshold. Universal input 5 pulse counter rollover threshold. Universal input 6 pulse counter rollover threshold. Universal input 7 pulse counter rollover threshold. Universal input 8 pulse counter rollover threshold. Polarity of universal input 1 when used in digital input mode Polarity of universal input 2 when used in digital input mode Polarity of universal input 3 when used in digital input mode Polarity of universal input 4 when used in digital input mode Polarity of universal input 5 when used in digital input mode Polarity of universal input 6 when used in digital input mode Polarity of universal input 7 when used in digital input mode Polarity of universal input 8 when used in digital input mode Start or stop copy configuration Select the unit system to use on the device Writable? Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Notes (* = default) ( = only when UniversalInputxFunction is set to 10K_Type3/G) -5.00 to 5.00 ºC/ºF/Volt/mA (default 0*) Resolution: 0.1 ºC/ºF/Volt/mA -5.00 to 5.00 ºC/ºF/Volt/mA (default 0*) Resolution: 0.1 ºC/ºF/Volt/mA -5.00 to 5.00 ºC/ºF/Volt/mA (default 0*) Resolution: 0.1 ºC/ºF/Volt/mA -5.00 to 5.00 ºC/ºF/Volt/mA (default 0*) Resolution: 0.1 ºC/ºF/Volt/mA -5.00 to 5.00 ºC/ºF/Volt/mA (default 0*) Resolution: 0.1 ºC/ºF/Volt/mA -5.00 to 5.00 ºC/ºF/Volt/mA (default 0*) Resolution: 0.1 ºC/ºF/Volt/mA 0-254 Address of first CMMB to copy Available only if BV.101 is set to No AV.468 (AV.468 + 64) Address of last CMMB to copy Available only if BV.101 is set to No AV.468 AV.469 Result of copy is available on Description property and is available only if BV.101 is set to Yes. Results: Succeed, Prog_Error, Type_Error, Model_Error, FW_Error, Mem_Error, Size_Error, Comm_Error, SlaveDevice, InProgress, AllSucceed Present Value 0 to 16777216, Resolution: 1 Present Value 0 to 16777216, Resolution: 1 Present Value 0 to 16777216, Resolution: 1 Present Value 0 to 16777216, Resolution: 1 Present Value 0 to 16777216, Resolution: 1 Present Value 0 to 16777216, Resolution: 1 Present Value 0 to 16777216, Resolution: 1 Present Value 0 to 16777216, Resolution: 1 Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= Direct * 1= Reverse 0= No * 1= Yes Start copy and give results, must be reset by user. 0= Celsius * 1= Fahrenheit 2 Write address in present value, result will be available in description. www.neptronic.com Page | 5 Dual Mini Input Communication Module Specification and Installation Instructions ID1 Name Description MSV.1 UniversalInput1Function Selected analog input 1 mode MSV.12 UniversalInput2Function Selected analog input 2 mode MSV.15 UniversalInput3Function Selected analog input 3 mode MSV.48 UniversalInput4Function Selected analog input 4 mode MSV.57 UniversalInput5Function Selected analog input 5 mode MSV.58 UniversalInput6Function Selected analog input 6 mode MSV.59 UniversalInput7Function Selected analog input 7 mode MSV.60 UniversalInput8Function Selected analog input 8 mode Writable? Present Value Present Value Present Value Present Value Present Value Present Value Present Value Present Value Notes (* = default) ( = only when UniversalInputxFunction is set to 10K_Type3/G) 1= 0_10V 6= 10K_Type2 2= 4_20mA 7= 20K_Type6A1 3= 10K_Type3/G* 8= 30K_Type6A1 4= 10K_Type3A1 9= Digital_Input 5= 10K_Type4A 10= 10K_NTC_Carel 1= 0_10V 6= 10K_Type2 2= 4_20mA 7= 20K_Type6A1 3= 10K_Type3/G* 8= 30K_Type6A1 4= 10K_Type3A1 9= Digital_Input 5= 10K_Type4A 10= 10K_NTC_Carel 1= 0_10V 6= 10K_Type2 2= 4_20mA 7= 20K_Type6A1 3= 10K_Type3/G* 8= 30K_Type6A1 4= 10K_Type3A1 9= Digital_Input 5= 10K_Type4A 10= 10K_NTC_Carel 1= 0_10V 6= 10K_Type2 2= 4_20mA 7= 20K_Type6A1 3= 10K_Type3/G* 8= 30K_Type6A1 4= 10K_Type3A1 9= Digital_Input 5= 10K_Type4A 10= 10K_NTC_Carel 1= 0_10V 6= 10K_Type2 2= 4_20mA 7= 20K_Type6A1 3= 10K_Type3/G* 8= 30K_Type6A1 4= 10K_Type3A1 9= Digital_Input 5= 10K_Type4A 10= 10K_NTC_Carel 1= 0_10V 6= 10K_Type2 2= 4_20mA 7= 20K_Type6A1 3= 10K_Type3/G* 8= 30K_Type6A1 4= 10K_Type3A1 9= Digital_Input 5= 10K_Type4A 10= 10K_NTC_Carel 1= 0_10V 6= 10K_Type2 2= 4_20mA 7= 20K_Type6A1 3= 10K_Type3/G* 8= 30K_Type6A1 4= 10K_Type3A1 9= Digital_Input 5= 10K_Type4A 10= 10K_NTC_Carel 1= 0_10V 6= 10K_Type2 2= 4_20mA 7= 20K_Type6A1 3= 10K_Type3/G* 8= 30K_Type6A1 4= 10K_Type3A1 9= Digital_Input 5= 10K_Type4A 10= 10K_NTC_Carel www.neptronic.com Page | 6 Dual Mini Input Communication Module Specification and Installation Instructions Modbus Registers · Register address o As per protocol base (base 0); for PLC add 1 to protocol base. o As per holding register (base 40001) · Functions : o 03 Read Holding Register o 06 Write Single Register o 16 Write Multiple Registers · Error Codes : o 02 Illegal Data Address o 03 Illegal Value o 06 Slave Device Busy · W = Writable register, [blank] = read only. · No Real number in modbus register, use scale to calculate real number. Register = Real number * Scale => Real number = Register / Scale. Scale could be 1, 10 or 100 · Attention when writing a register that contains a bit string. If bit is writable (conditional or not), the write will always be accepted. If bit is reserved or not writable, the write will be ignored and will keep its actual state. · Use READ-MODIFY-WRITE sequence. Protocol Holding Base Register Description Data Type MSB/LSB Units/Values 0 40001 MSB = Neptronic Device ID LSB = MAC Address Unsigned 105 (69h) [1..247] (1h- F7h) * MAC address is writable if all DIP switches of DS2 are OFF. 1 40002 Device Baud Rate Unsigned Scale 0.01 [96] [192] [384] [576] 9,600 19,200 38,400 57,600 COM Port Configuration IMPORTANT: The default value is "no parity, 2 stop bits". To change the value, you must set 2 40003 DIP switch DS1-3 to OFF. If set to ON, it will Unsigned [0..2] always remain at the default value. Refer to 0 = no parity, 2 stop bits 1 = even parity, 1 stop bit 2 = odd parity, 1 stop bit Connections and Configurations on page 2. 3 40004 Product Name (characters 8 & 7) 2 x ASCII char 8 char 7 Valid ASCII character: 32 (20h) 122 (7ah), Empty = 0 4 40005 Product Name (characters 6 & 5) 2 x ASCII char 6 char 5 Valid ASCII character: 32 (20h) 122 (7ah), Empty = 0 5 40006 Product Name (characters 4 & 3) 2 x ASCII char 4 char 3 Valid ASCII character: 32 (20h) 122 (7ah), Empty = 0 6 40007 Product Name (characters 2 & 1) 7 40008 Firmware Version 2 x ASCII Unsigned Scale 100 char 2 char 1 102 Valid ASCII character: 32 (20h) 122 (7ah), Empty = 0 1.02 Writable Default Value MB LB W* 69h 1h 96 W 0 W 43h [C] 40h [M] W 40h [M] 42h [B] W 31h [1] 30h [0] W 36h [6] 20h [ ] 102 www.neptronic.com Page | 7 Protocol Holding Base Register Description 8 40009 Application Version 9 40010 System Status 1 10 40011 11 40012 12 40013 13 40014 14 40015 15 40016 16 40017 17 40018 18 19 to 25 26 40019 40020 to 40026 40027 27 40028 28 40029 29 40030 30 40031 31 40032 32 40033 33 40034 34 40035 35 40036 36 40037 37 40038 38 40039 39 40040 System Status 2 Analog Input 1 Analog Input 2 Analog Input 3 Analog Input 4 Analog Input 5 Analog Input 6 Analog Input 7 Analog Input 8 Reserved Universal Input 1 Function Universal Input 2 Function Universal Input 3 Function Universal Input 4 Function Universal Input 5 Function Universal Input 6 Function Universal Input 7 Function Universal Input 8 Function Universal Input 1 Offset Universal Input 2 Offset Universal Input 3 Offset Universal Input 4 Offset Universal Input 5 Offset Universal Input 6 Offset www.neptronic.com Dual Mini Input Communication Module Specification and Installation Instructions Data Type MSB/LSB Units/Values Unsigned Scale 100 100 Bit String [B0..B15] Bit String [B0..B15] 1.00 0 = Normal 1 = Fault - - - - - - - - - - - - - - - - - - B0 = System operation Always 0 0-10V: Type: Unsigned, Scale:100, Unit: Volt, Range: 0.00-10.00V, Resolution: 0.01 4-20mA: Type: Unsigned, Scale:100, Unit: mA, Range: 4.00-20.00 mA, Resolution: 0.01 10K Type 3A1, 10K Type 4AI, 10K Type 2, 20K Type 6AI, 30K Type 6AI: Type: Signed, Scale:100, Unit: ºC, Range: -40.00 - 100.00 ºC, Resolution: 0.01 Type: Signed, Scale:100, Unit: ºF, Range: -40.00 - 212.00 ºF, Resolution: 0.02 10K Type 3/G: Type: Signed, Scale:100, Unit: ºC, Range: -40.00 - 150.00 ºC, Resolution: 0.01 Type: Signed, Scale:100, Unit: ºF, Range: -40.00 - 302.00 ºF, Resolution: 0.02 DI: Type: Unsigned, Scale:1, No Unit, Range: 0-1, Resolution: 1 Writable Default Value MB LB 100 0000, 0001, 1111, 1110b 0000, 0000, 0000, 0000b 0 0 0 0 0 0 0 0 Unsigned [1..10] Signed Scale 100 [0..100] 1= 0_10V 2= 4_20mA 3= 10K_Type3/G * 4= 10K_Type3A1 5= 10K_Type4A1 6= 10K_Type2 7= 20K_Type6A1 8= 30K_Type6A1 9= Digital_Input 10= 10K_NTC_Carel Range: +/- 5.00, Resolution: 0.1 3 3 3 3 W 3 3 3 3 0 0 0 W 0 0 0 Page | 8 Protocol Holding Base Register Description 40 40041 41 40042 42 to 53 40043 to 40054 Universal Input 7 Offset Universal Input 8 Offset Reserved System Options 54 40055 * = digital input mode only 55 to 76 40056 to 40077 77 40078 78 40079 79 40080 80 40081 81 40082 82 40083 83 40084 84 40085 85 40086 86 40087 Reserved UI1 Pulse Prescaler (0) UI1 Pulse Prescaler (1) UI2 Pulse Prescaler (0) UI2 Pulse Prescaler (1) UI3 Pulse Prescaler (0) UI3 Pulse Prescaler (1) UI4 Pulse Prescaler (0) UI4 Pulse Prescaler (1) UI5 Pulse Prescaler (0) UI5 Pulse Prescaler (1) www.neptronic.com Dual Mini Input Communication Module Specification and Installation Instructions Data Type MSB/LSB Units/Values Signed Scale 100 [0..100] Range: +/- 5.00, Resolution: 0.1 Writable Default Value MB LB 0 W 0 Bit String [B0..B15] 0 = Direct 1 = Reverse - - - - - - - - - - - - - - - - - - B0 to B3 = Reserved B4 = AI1 polarity * B5 = AI2 polarity * B6 = AI3 polarity * B7 = AI4 polarity * B8 = AI5 polarity * B9 = AI6 polarity * B10 = AI7 polarity * B11 = AI8 polarity * B8 to B14 = Reserved - - - - - - - - - - - - - - - - - - 0 = Celsius 1 = Fahrenheit - - - - - - - - - - - - - - - - - - B15 = System Unit W 0000, 0000, 0000, 0000b Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 W 1 W 1 W 1 W 1 W 1 Page | 9 Protocol Holding Base Register Description 87 40088 UI6 Pulse Prescaler (0) 88 40089 UI6 Pulse Prescaler (1) 89 40090 UI7 Pulse Prescaler (0) 90 40091 UI7 Pulse Prescaler (1) 91 40092 UI8 Pulse Prescaler (0) 92 40093 UI8 Pulse Prescaler (1) 93 40094 UI1 Pulse Count (0) 94 40095 UI1 Pulse Count (1) 95 40096 UI2 Pulse Count (0) 96 40097 UI2 Pulse Count (1) 97 40098 UI3 Pulse Count (0) 98 40099 UI3 Pulse Count (1) 99 40100 UI4 Pulse Count (0) 100 40101 UI4 Pulse Count (1) 101 40102 UI5 Pulse Count (0) 102 40103 UI5 Pulse Count (1) 103 40104 UI6 Pulse Count (0) 104 40105 UI6 Pulse Count (1) 105 40106 UI7 Pulse Count (0) 106 40107 UI7 Pulse Count (1) 107 40108 UI8 Pulse Count (0) 108 40109 UI8 Pulse Count (1) 109 40110 UI1 Accumulator (0) 110 40111 UI1 Accumulator (1) www.neptronic.com Dual Mini Input Communication Module Specification and Installation Instructions Data Type MSB/LSB Units/Values Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Writable Default Value MB LB W 1 W 1 W 1 W 0 W 0 W 0 W 0 W 0 W 0 W 0 W 0 W 0 Page | 10 Protocol Holding Base Register Description 111 40112 UI2 Accumulator (0) 112 40113 UI2 Accumulator (1) 113 40114 UI3 Accumulator (0) 114 40115 UI3 Accumulator (1) 115 40116 UI4 Accumulator (0) 116 40117 UI4 Accumulator (1) 117 40118 UI5 Accumulator (0) 118 40119 UI5 Accumulator (1) 119 40120 UI6 Accumulator (0) 120 40121 UI6 Accumulator (1) 121 40122 UI7 Accumulator (0) 122 40123 UI7 Accumulator (1) 123 40124 UI8 Accumulator (0) 124 40125 UI8 Accumulator (1) Dual Mini Input Communication Module Specification and Installation Instructions Data Type MSB/LSB Units/Values Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 Unsigned Scale 1 [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] [0...16777216] Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Range: 0 to 16777216, Resolution: 1 Writable Default Value MB LB W 0 W 0 W 0 W 0 W 0 W 0 W 0 www.neptronic.com Page | 11 Recycling at end of life: please return this product to your Neptronic local distributor for recycling. If you need to find the nearest Neptronic authorized distributor, please consult www.neptronic.com. 400 Lebeau blvd, Montreal, Qc, H4N 1R6, Canada www.neptronic.com Toll free in North America: 1-800-361-2308 Tel.: (514) 333-1433 Fax: (514) 333-3163 Customer service fax: (514) 333-1091 Monday to Friday: 8:00am to 5:00pm (Eastern time)