JBC B.IRON DUAL 500 Dual Battery-Powered Soldering Station
Instruction Manual
Product website: www.jbctools.com
Introduction
This manual corresponds to the following references:
- BISS-5B* - with Portable Display
- BISS-5QB* - without Portable Display
* Depending on customer requirements, various power cords are available, suitable for: 120V - N. America / Taiwan, 230V - India / Europe / United Kingdom
Packing List
The following items are included:
- Charging-Base with Charging-Holders already assembled - 1 unit
- C210 Cartridge (tip ø 0.3 mm) - 2 units (Ref. C210001)
- B.500 Handle for B.IRON - 2 units (Ref. B500-B) (Includes Handles + B1596 Safety Caps + OB4000 Sealing Plugs + B5050 Grips + fitters)
- Brass Wool for B.IRON Charging-Base - 1 unit (Ref. CL0300) (Already assembled in the charging base)
- B.IRON Display Holder 5" to 7" - 1 unit (Ref. 0030723) (Includes fixing knob)
- Cable USB-A to USB-C ** - 1 unit (Ref. 0032705)
- Portable Display 7" for B.IRON ** - 1 unit (Ref. PDS-B)
- Quick Start Guide - 1 unit
- Manual - 1 unit (Ref. 0034645)
* One power cord included according to customer requirements. ** Not included in BISS-5QB.
Important Notes
Please read this manual and its safety guidelines thoroughly before using the product.
Note: Even if the display is turned off and the charging base is disconnected from the mains, the tool remains operational as long as the batteries are charged, even when the cartridge is taken out.
⚠️ The tool turns off automatically only under the following conditions:
- The tool is out of the charging holder (no safety cap on) and remains completely still for 5 minutes (see page 8).
- The tool has the safety cap on and remains completely still for 60 minutes (see page 9).
- The tool is in the charging holder and the charging base is disconnected from the mains.
The tool can be manually switched off and on by tapping the tool power button on the display (see page 9).
Features and Connections
PDS* Portable Display 7" for B.IRON
Cartridge Exchanger H2464 (Left-Side Charging-Holder for B.IRON Handles)
CL0300 Brass Wool for B.IRON Charging-Base (inside)
Cartridge Holder H2465 (Right-Side Charging-Holder for B.IRON Handles)
CL0301 Wiper for B.IRON Charging-Base
* Not included in ref. BISS-5QB
Diagram Description: The diagram shows the JBC B.IRON 500 soldering station. The Portable Display (PDS) is mounted on a holder. Two B.500 Handles for B.IRON are shown connected to the charging base via charging holders. The charging base has slots for the handles, a safety cap holder, a USB connector, and a power socket. A C210 Cartridge Range is depicted near each handle. A USB-A to USB-C cable is shown connecting to the display holder. Bluetooth connections are indicated between the display and the charging base.
ESD Safe Connection: All B.IRON components comply with CE standards, but the tool by itself is not grounded. To comply with ESD regulations, the user must be ESD-compliantly grounded. JBC offers ESD tablemats, earthing cables, plugs, and wristbands. More information is available on www.jbctools.com.
Station Setup
Display Holder Assembling
Step 1: Insert the thin end of the display holder into the upper area of the rear rail of the charging base.
Step 2: Carefully rotate the display holder 90 degrees until it stands vertical.
Display Holder Setting
Insert the fixing knob and tighten it just enough so that it stays in place but the display holder can be moved.
Base and Display Connection
Step 4: Connect the charging base to the mains.
Step 5: The display can be connected to the USB port (5) with the provided USB cable to keep it charging while working.
Display Placing
Place the display on the support with its buttons facing upwards. Adjust the height of the display holder and tighten the fixing knob.
Turn on the display by holding down the power button for a while (6) and then open the B.IRON app*.
* Note: The app can also be downloaded to your own devices. To know how, see section “Installing and Updating the B.IRON App”.
Cartridge Exchanger
The exchanger is suitable for C115 and C210 cartridges.
C115 Cartridges
The holding area of C115 Cartridges is delimited by the two rings at the cartridge shaft (x).
C210 Cartridges
The holding area of C210 Cartridges goes from the collar of the tip until the cartridge begins to widen (x).
Cartridge Changing
Step 1: Place the tool with the cartridge over the cartridge exchanger slots and press down until it clicks.
Step 2: To remove the cartridge, pull the handle out.
To insert a cartridge, carry out the same steps as before in reverse order.
Cartridges must be inserted up to the mark for a proper connection and functioning.
Cartridge Fixing
Gently press the tip against the holes on the sides of the cartridge exchanger (3) to ensure that the cartridge is appropriately inserted.
Tool Charging
Place the tool in the charging holder (4) to charge it. A beep will sound when the tool is properly placed and charging. The volume can be adjusted using the left button on the display.
Important: Charge the tool completely before using it for the first time.
A full charge takes:
- -30 min for B.100
- -60 min for B.500
- -30 min for B.NANO
- -45 min for B.TWEEZERS
Operation
Thanks to the intelligent heat management, the cartridge tip recovers temperature extremely quickly.
This allows reducing the tip temperature when the device is not in use, resulting in a longer tip lifespan.
When the tool enters Sleep (1) or Hibernation (2) Modes, the tip temperature lowers automatically below the solder-melting-point temperature.
Diagram Description: A graph shows Temperature (Y-axis) vs. Time (X-axis). It illustrates Work temperature, Sleep temperature, and Room temperature. It shows the tool in a charging holder and heating phases.
Tool Status
The tool can go into a number of statuses under different circumstances. Depending on the status, the cartridge tip reaches different temperatures:
| Tool Status | Tip Temperature |
|---|---|
| Sleep and charging | Cools down to the set Sleep temperature. Selectable between 70 °C and 150 °C. |
| Hibernation and charging | Cools down to room temperature. |
| Working | Heats up to the set work temperature. |
| Resting without cap | Cools down to room temperature (after 5 min of being completely still). |
| Tool with cap on | Cools down to room temperature. |
| Hibernation | Cools down to room temperature. |
| Shut off | Remains at room temperature (tool is shut off). |
Sleep and Charging
Sleep Mode can be activated/deactivated (1). If it is activated and the tool is placed in the charger, the tip cools down to sleep temperature and the tool keeps charging.
Hibernation and Charging
If Sleep Mode is not activated and the tool is placed in the charger, it goes into Hibernation. The tip cools down to room temperature and the tool keeps charging.
Screenshot Description: A screenshot of the JBC B.IRON app settings shows options like Tool ID, Hibernation delay, Temperature units, Lock Parameters, Sleep mode, Sleep temperature, Minimum temperature, and Maximum temperature.
Tool Status Flowchart
Diagram Description: A flowchart illustrates the tool's status transitions:
- SLEEP & charging (1): Activated by Sleep ON. Tool is picked up (reactivation).
- WORK (3): Reached from SLEEP & charging or HIBERNATION & charging when the tool is picked up.
- HIBERNATION & charging (2): Activated by Sleep OFF. Tool is placed in charger.
- HIBERNATION: Reached from WORK when the tool is laid down (4) or cap is placed on (5).
- AUTO SHUT-OFF (6, 7, 8): Occurs after a period of inactivity in HIBERNATION mode (5 min without cap, 60 min with cap) or when the tool is in the charger and the base is disconnected from mains (8).
Work
When the tool is taken out of the charger while in Sleep (1) or Hibernation (2) Modes, the cartridge tip heats up to the set work temperature and the tool is ready to use (3).
Hibernation
The tool goes into Hibernation Mode in two different cases:
- a) After working, when the tool is laid down (4) and is resting between 5 and 10 seconds (time is adjustable).
- b) After working, when placing the cap on the tool (5).
Note: Before the tool enters Hibernation Mode, it can be picked up to work with it and the cartridge tip heats up to work temperature.
Auto Shut-off
The tool shuts off automatically in three different cases:
- a) When the tool (without the tool cap) is laid down and remains completely still in Hibernation Mode for 5 minutes (6).
- b) When the tool (with the tool cap on) remains completely still in Hibernation Mode for 60 minutes (7).
- c) When the tool is in the charger and the charging base is disconnected from the mains (8).
Tool Reactivation and Manual Shut-Off
Tool Reactivation
Once the tool has automatically shut off, place it back in the charging holder (9) to reactivate it (see diagram on previous page).
Manual Tool Shut-Off
Besides the “automatic shut-off” feature, the tool can also be manually switched off by tapping the tool power button on the display. When it is switched off, the cartridge cools down to room temperature.
Note: To switch the tool back on, tap the same button on the display.
Diagram Description: A graph shows temperature and power. A button labeled "Tool ON/OFF Button" is indicated.
Safety Cap
Safe Tool Transportation
Thanks to the tool's safety cap, B.IRON tools can be carried around safely, even with the cartridge inserted.
When the cap is placed onto the tool, it goes into Hibernation Mode immediately and the cartridge tip cools down to room temperature.
Note: The purpose of the cap is to allow safe transport, not storage.
Safety Cap Holder
While the tool is in use, the safety cap can be stored on the cap holder located on the back of the charging base. There is space for two caps.
Tool Connection
Make sure that the charging base is connected to the mains.
Note: Tools supplied with a station are already connected to the station.
Scanning another tool
Process: Place the tool in the charging holder to activate it. The status light band color indicates the charge level (see table below).
If the scanning process does not run automatically, tap “scan” (6) on the display while the tool remains in the charging holder. When the tool is shown in the device list on the display, select it (11) and tap “connect” (7). Now the tool is ready for soldering.
Tool search function
When in doubt of which tool corresponds to the tool's name, use the tool search function. Tap on the magnifying glass symbol (8) next to the tool's name. The light band on the corresponding tool blinks in blue for five seconds to identify it.
Working with two tools
(Works also for charging bases with only one charging holder)
It is possible to connect up to two tools at the same time. If a tool is already connected, first disconnect it from the device by selecting “Menu” (9) and tapping on “Disconnect”.
Place the second tool in the charging holder and scan it (6). The second tool is also shown in the device list on the display (10). To work with two tools, select one from the left-hand column (11) and the other one from the right-hand column (10). Then tap on “connect” (7).
Status Lightband
The status lightband on the tool indicates its status (see table on the right).
| Color | Tool Status |
|---|---|
| Green | More than 50% charged |
| Orange | Between 20% and 50% charged |
| Red | Less than 20% charged |
| Green blinking | Charging (more than 50% charged) |
| Orange blinking | Charging (between 20% and 50% charged) |
| Red blinking | Charging (less than 20% charged) |
| No color | Safety cap on the handle and/or power off |
| Blue blinking | Locate Tool function activated |
Work Screen
The work screen shows a graph of the tip temperature and power supplied to the tip updated in real time. It allows modifying the tool working temperature, checking the battery status and turning the tool in use on and off.
Diagram Description: The work screen displays a real-time graph of Temperature and Power. The Y-axis shows temperature (50°C to 450°C) and power (0W to 24W). The X-axis shows time (10 seconds/div). Controls for Temperature Scale, Working Temperature Selection Slider, and Power Scale are visible. The current temperature is shown as 350°C.
Graph and Automatic Data Display
The graphs of temperature and supplied power start automatically as soon as the tool is lifted from the charging base.
The graph display can be paused while working by tapping the screen on the graph area. While the automatic display is on hold, the temperature/power values can be checked at a certain point of the graph by tapping on the desired position on the display screen.
Note: Pausing the automatic display by tapping on the screen does not stop the tool from heating up, and the tip will remain at the selected working temperature. The graph display automatically continues after 5 seconds.
The graph can be moved to the left and right by swiping the touch screen sideways with one finger.
Working Temperature Modification
The working temperature can be modified using the slider below the graph (± 5 °C / ± 10 °F).
Stopping Data Display
When the tool is placed in the charging holder or when it enters Hibernation Mode, the data display stops.
The display starts again automatically when the tool is lifted from the tool holder and the graph is automatically displayed again at the point where the previous display stopped, leaving a small gap on the graph between the last registered value and the new starting point.
Working with Two Tools
When working with two tools, to switch between the two graphs, tap on the tool selector (upper-right corner of the display) and select the desired tool from the drop-down menu.
It is also possible to alternate both graphs by simply lifting one tool or the other from the tool holder. The display will automatically show the graph and information of the tool in use.
Note: All menu items are explained in detail starting at section “Menu”.
Settings Details
| Parameter | Description |
|---|---|
| Tool ID | Allows modifying the tool identifier. |
| Lock parameters | Allows locking the parameters of the station using a four-digit code. The default code is 0105, but a new code can be set by simply entering some other four digits of choice when locking the parameters. |
| Sleep Mode / Sleep temperature | Set Sleep Mode on/off. The tip temperature drops only to the selected Sleep temperature when placed on the tool holder. |
| Hibernation delay | Set Hibernation delay from 5 to 15 sec. The countdown starts when the tool remains inactive (no movement). |
| Minimum temperature | Define the minimum selectable working temperature. |
| Maximum temperature | Define the maximum selectable working temperature. |
| Temperature units | Allows changing the units of temperature measurement between degrees Celsius and degrees Fahrenheit. |
Compatible Cartridges
B.500 Handle works with C210 Cartridges. Find the model that best suits your soldering needs on www.jbctools.com
Cartridge Types: Conical, Chisel, Conical Bent, Bevel.
Inserting C210 Cartridges
Push the cartridges inside the handle until the reference mark is aligned with the edge of the handle.
C210 Cartridge Holder
The cartridge holder (4x slots) is used to store cartridges. It allows having different cartridges quickly at hand and it works with C210 Cartridges.
Wiper and Tip Cleaner
Select the tip cleaning option that best suits your needs and improve the tip thermal transfer.
CL0301 Wiper for B.IRON Charging-Base includes an anti-splash area that prevents solder particles from splashing onto the working area, keeping the workplace clean. It also includes a temperature-resistant wiper area for removing excess solder by gently tapping or wiping the cartridge tip on it.
Tapping
Tap gently to remove excess solder.
Wiping
Use the slots to remove remaining particles.
Brass Wool (inside)
CL0300 Brass Wool is a very effective cleaning method. It leaves a small layer of solder on the tip, preventing oxidation between cleaning and rewetting.
Note: If the tip is very dirty, JBC recommends cleaning it first with the wiper to remove excess solder and then with the brass wool.
Replacing Brass Wool
Step 1: Lift the wiper membrane by using the recess on the edge.
Step 2: Remove the wiper and replace the brass wool with a new one. Make sure that the brass wool is on the far left and that there is space for the wiper on the right.
Step 3: Press the wiper membrane down at the 4 corners until you feel it click into place. Make sure that the wiper membrane is inserted correctly all the way around.
Note: The brass wool and the wiper positions can be reversed by rotating the anti-splash membrane 180 degrees.
JBC Software
No installation or initial download are required for newly purchased JBC products. Both JBC display and tools come with its current software/firmware installed and updated, and are ready to use.
Note: App: If a third-party display (tablet or smartphone) is used, the B.IRON app must be downloaded from JBC's web page and installed on the device. Firmware: The tool's firmware is not automatically updated and the updates must be carried out manually by the user. To do so, follow the instructions on the next page.
App Versions
Make sure that the required app version is installed on the display (tablet or smartphone):
- Handles require app versions 1.6 or higher.
- Tweezers require app versions 1.7 or higher.
App Installation
On JBC's portable display (Android), the B.IRON app is already installed.
On the user's smartphone or tablet (Android / iOS), go to the App Store/Play Store and search for "JBC B.IRON" on the search bar. Note: Internet connection is required to download the app.
Alternatively, scan these QR codes to access the B.IRON app page directly:
[QR Code for App Store] [QR Code for Google Play]
App Update
Display with Internet connection (Android / iOS)
Update the app via Google Play (Android) or the App Store (iOS).
Display without Internet connection (Android)
Download JBC's installer program to another device with an Internet connection from JBC's website: https://www.jbctools.com/jbcsoftware.html
Then copy the downloaded program to the internal storage of the display used with B.IRON. Access the internal storage of the display and run the downloaded program. Once the program is completed, the app will be updated to the latest version.
Note: For JBC displays, swipe down to open the internal storage folder.
Downloading the Tool Firmware Update File
Display with Internet connection:
Download the firmware update file to the display used with B.IRON from https://www.jbctools.com/jbcsoftware.html. Go to the internal folder and unzip the downloaded file.
Display without Internet connection:
Download the firmware update file to another device with an Internet connection from JBC's website: https://www.jbctools.com/jbcsoftware.html and unzip the downloaded file.
Then do as described in the table:
| PDS (JBC's display android) | Other android devices | iOS devices |
|---|---|---|
| Folder: \Internal shared storage\Android\data\es.infinitysource.jbc_soldering.JBCBiron\files | Folder: \Internal shared storage\Android\data\com.jbctools.jbcbiron\files | Path: Files > On my iPad > JBC B.iron > B.I |
Executing the Tool Firmware Update File
Tool firmware updates are not executed automatically; they must be carried out by the user.
On the display you are using with B.IRON, and with the latest app version installed, access the B.IRON app.
Select the tool you want to update. Then, in the main menu, select “update”.
Note: At least one tool must be connected to see the expanded menu options.
Diagram Description: A screenshot of the JBC B.IRON Nano shows "Current version" and "New version" with an "Update" button. Another shows "Tool updated". A third shows "No new version available".
Executing the Tool Firmware Update File (continuation)
If the downloaded tool firmware update file contains a newer version than the one already installed, the current and new version are displayed (1). Tap “Update” to start the update (2).
The update process takes about 10 minutes.
Note: If the firmware update is interrupted, the app automatically recognizes this and starts a new update process. “Device needs recovery” appears on the top left corner of the display. Press the “Update” button (2) in the pop-up window to continue the firmware update.
The B.IRON status light continuously changes its color during the update process.
Once the update is completed, “Tool updated” (3) will be displayed.
If “No new version available” is displayed (4), no update is possible or required.
Accessories
Soldering Tools for B.IRON Stations
- B.NANO* Nano Handle for B.IRON: Ergonomic and lightweight soldering handle. Designed for use in labs and high-precision soldering in hard-to-reach areas. Works with C115 Cartridges.
- B.TWEEZERS* Nano Tweezers for B.IRON: Powerful and efficient soldering tweezers. Designed for use in labs and soldering rework jobs. Works with C115 Cartridges.
- B.100* Light Handle for B.IRON: Ergonomic and lightweight soldering handle. Designed for use in labs and individual soldering jobs. Works with C210 Cartridges.
- B.500* Handle for B.IRON: Powerful and efficient soldering handle. Designed for use in production and intensive soldering jobs. Works with C210 Cartridges.
* Cartridges not included. To charge the tools, a B.IRON charging base or station is needed. Required app version: For handles, 1.6 or higher and for tweezers, 1.7 or higher.
Tool Expansion Kits for B.IRON Stations
- B.NANO K* Nano Handle Expansion Kit: This kit allows extending B.IRON stations with B.NANO Handle. Works with C115 Cartridges.
- B.TWEEZERS K* Nano Tweezer Expansion Kit: This kit allows upgrading B.IRON stations to a rework station by adding B.TWEEZERS. Works with C115 Cartridges.
- B.100 K* Light Handle Expansion Kit: This kit allows extending B.IRON stations with B.100 Light Handle. Works with C210 Cartridges.
- B.500 K* Handle Expansion Kit: This kit allows extending B.IRON stations by adding B.500 Handle. Works with C210 Cartridges.
* Cartridges not included. To charge the tools, a B.IRON charging base or station is needed. Required app version: For handles 1.6 or higher and for tweezers 1.7 or higher.
Maintenance
Maintenance - B.IRON Handles
Replacing Soft Foam Grips - B5050
Inserting Fitters: Insert the fitters into the new grip.
Assembling Grips: Push the grip with the fitters onto the handle.
Removing Fitters: Hold the grip and pull the fitters out. Use pliers if necessary.
Sealing Plugs
The sealing plug prevents undesirable flux vapors or particles from entering the handle and its usage is highly recommended. If the sealing plug is not used, this can lead to incorrect cartridge contact and may render the tool unusable.
Note: Check the condition of the plug periodically and replace it as soon as wear or cracking is detected.
⚠️ Before replacing the sealing plug, disconnect the handle from the station and make sure the device has cooled down.
| Handle | Sealing Plug Ref. |
|---|---|
| B.NANO | OB5000* |
| B.100 and B.500 | OB4000* |
* Each ref. comes with 10 sealing plugs
Replacing Sealing Plug for B.100 & B.500 Handles - OB4000
Introduce a small shaft or screwdriver, not deeper than 8 mm, lift and pull the sealing plug. Never use a cartridge to do this operation.
Push the sealing plug inside the handle. Note: The chamfered side of the sealing plug has to be positioned towards the handle.
Make sure the sealing plug is placed correctly. The edge of the sealing plug must rest in the groove of the tool bushing.
Maintenance - Station and Tools
Before carrying out maintenance, always extract the cartridge from the tool and disconnect the charging base from the mains. Allow the equipment to cool down.
- Use a damp cloth to clean the casing and the tool. Alcohol can only be used to clean the metal parts.
- Periodically check that the metal parts of the tool and charging holder are clean so that the charging works properly.
- Keep the tip surface clean and tinned prior to storage in order to avoid tip oxidation. Rusty and dirty surfaces reduce heat transfer to the solder joint.
- Do not use liquids such as alcohol, thinner or benzene to clean the portable display.
- Repairs should only be performed by a JBC authorized technical service.
Diagram Description: Shows the soldering station with labels pointing to "Clean the contact surfaces regularly to ensure that the tool gets charged correctly."
Safety - Battery
⚠️ It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion.
Caution: This product contains lithium-ion batteries. Mishandling or improper use may result in fire, explosion, or personal injury.
- Always use the provided charger. Do not use damaged chargers or batteries.
- Never attempt to disassemble or modify the batteries or the product. Doing so may lead to electric shock, fire, or damage to the product.
- In the event of damage, leakage, or overheating of the batteries, discontinue use immediately and contact customer support or JBC technical service facility.
- Dispose of devices with batteries inside, responsibly according to regulations. They must be disposed of in accordance with local regulations so that they can be recycled.
- Do not throw devices with batteries into household waste and do not dispose of them in fire or water.
Safety
⚠️ It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion.
- Do not use the units for any purpose other than soldering or rework. Incorrect use may cause a fire.
- The power cord must be plugged into approved bases. When unplugging it, hold the plug, not the wire.
- Do not attempt to dismantle or open the housing of the tool as it may cause damage.
- Do not work on electrically live parts.
- The tool should be placed in the charging holder when not in use in order to charge the batteries.
- The soldering tip, the metal part of the tool and the charging holder may still be hot even when the station is turned off.
- Do not leave the tool unattended when it is on.
- Avoid flux coming into contact with skin or eyes to prevent irritation.
- Be careful with the fumes produced when soldering.
- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working to avoid personal harm.
- Utmost care must be taken with liquid tin waste, which can cause burns.
- This appliance can be used by children over the age of eight and also persons with reduced physical, sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning the use of the appliance and understand the hazards involved. Children must not play with the appliance.
- Maintenance must not be carried out by children unless supervised.
- Do not expose the portable display to high temperatures, humidity or dust. Avoid direct sunlight.
- Do not drop the portable display or the tool, as it may cause damage or malfunction.
- Do not disconnect your device when it is in file transfer mode.
- Do not use the portable display in places where wireless communications are restricted.
Specifications
B.IRON DUAL 500 Dual Battery-Powered Soldering Station
Ref. BISS-5B - with Portable Display
Ref. BISS-5QB - without Portable Display
Charging-Base
- Input: 100 V - 240 V 50/60 Hz
- Nominal Power: 70 VA
- Tool Output: 12 V / 1500 mA
- USB Output: 5 V / 1000 mA
B.500 Handle
- Peak Power (Tool): 24 W
- Battery: Li-Ion 7.4 V / 750 mAh
- Charge Time: 60 minutes
- Selectable Temperature: 100 - 450 °C / 210 - 840 °F
- Idle Temp. Stability (still air): ±1.5 °C / ±3 °F
- Temp. Accuracy: ±3% (using reference cartridge)
- Connections: Bluetooth Low Energy (BLE)
- Ambient Operating Temp.: 10 - 50 °C / 50 - 122 °F
- Tool Weight: 70 g / 0.154 lb
Portable Display 7"
- Display Dimensions: 7" / 7 in
Ref. BISS-5B with Portable Display:
- Total Net Weight: 2.13 kg / 4.70 lb
- Total Package Dimensions/Weight: (L x W x H) 265 x 223 x 160 mm / 2.74 kg (10.43 x 8.78 x 6.30 in / 6.04 lb)
Ref. BISS-5QB without Portable Display:
- Total Net Weight: 1.68 kg / 3.70 lb
- Total Package Dimensions/Weight: (L x W x H) 225 x 223 x 160 mm / 2.25 kg (8.86 x 8.78 x 6.30 in / 4.96 lb)
Complies with CE standards.
ESD safe (to comply with ESD requirements, see page 4).
Warranty
JBC's 2 year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labor.
Warranty does not cover product wear or misuse.
In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased.
Get 1 extra year JBC warranty by registering here: https://www.jbctools.com/productregistration/ within 30 days of purchase.
If you register, you will receive e-mail notifications about new software updates for your registered product.
This product should not be thrown in the garbage. In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must be collected and returned to an authorized recycling facility.
CE EAC UK CA
www.jbctools.com
Notes
(Blank section for user notes)