Keiser Lat Pulldown Pro Operation Manual
Models: 002133BP, 002133XP
Notice: Legacy Model Applicability. This manual also covers legacy Lat Pulldown Pro models 002133BP/002133XP with lap belt and arm plunger knobs manufactured before April 2025. Users should refer to the safety, operation, and care sections, noting adjustments may not apply.
Contents
General Information
Introduction
Congratulations on the purchase of your new Keiser Lat Pulldown Pro and welcome to the Keiser family. Keiser's Dynamic Variable Resistance safely builds strength at any speed, which is key to building maximum power.
For your safety, and to ensure the best experience and maximum gains, it is critical that you read and understand this manual before you begin using the Lat Pulldown Pro. If you have any questions regarding the operation of the Lat Pulldown Pro after reading this manual, our Keiser Customer Support team will be happy to assist by telephone at 1 559 256 8000 and via live chat at keiser.com/support (Monday-Friday, 7 am to 5:30 pm PST), or by email at service@keiser.com.
Yours in Health,
Keiser Corporation
Register Your Purchase
Register your Lat Pulldown Pro to stay informed of safety notifications and for faster, more accurate warranty service. Scan the QR Code to the right to access the interactive online warranty registration form or visit: https://www.keiser.com/forms/warrantyregistration
Serial Number Information
Please take a moment at this time to record the serial number in the space provided below.
Serial No.: _________________________
| Label | Description |
|---|---|
| A | Manufacturer name, logo, and address |
| B | Country of manufacture |
| C | Patent information notification |
| D | WEEE mark [WEEE Mark] |
| E | CE mark [CE Mark] |
| F | Maximum User Weight Limit: 441 lbs (200 kg) |
| G | Serial number and date of manufacture |
| H | Model number and product description (e.g., MODEL: 002133BP) |
Marking plate illustration is for reference only. Refer to the marking plate attached to the equipment for specific product information.
Important Safety Information
It is the sole responsibility of the purchaser of Keiser Corporation equipment to instruct all individuals, whether they are the end-user or supervising personnel, on proper usage of the equipment. Keiser Corporation recommends that all users of its equipment be informed of the following information before use.
- Read these instructions.
- Heed all warnings.
- Follow these instructions.
- Intended use of the Lat Pulldown Pro is for physical activity or Physiotherapy (sometimes referred to as physical therapy).
- The Lat Pulldown Pro is intended for individuals aiming to maintain and restore maximum movement and functional ability throughout their lifespan, including circumstances where movement and function are limited by aging, injury, pain, disease, disorders, conditions, or environmental factors, especially in case of using the Lat Pulldown Pro in physical therapy.
- Consult your physician before beginning any exercise program.
- The Lat Pulldown Pro is intended for use in training areas of organizations where access and control are specifically regulated by a person responsible for determining the suitability of use and maintenance.
- Maximum user weight limit: 441 lbs (200 kg).
- Use the Lat Pulldown Pro indoor in a climate-controlled environment only. Keep away from areas of extreme humidity.
- The use of this Lat Pulldown Pro for any purpose not explicitly specified by the manufacturer in this manual is prohibited.
- Wear proper exercise clothing and shoes for exercise. Avoid wearing loose clothing that might catch on any moving parts. Tie long hair back.
- The Lat Pulldown Pro is not a toy. Children shall not play with the Lat Pulldown Pro. Children under 14 years old should not use the Lat Pulldown Pro. Keep children and pets clear from the Lat Pulldown Pro at all times, especially while in use. Cleaning and user maintenance shall not be performed by children.
- The Lat Pulldown Pro can be used by children age 14 years and above. Persons with mental disabilities, reduced physical, mental, or sensory capabilities, or lack of experience or knowledge should not use the Lat Pulldown Pro without constant supervision by a spotter/supervisor.
- Proper warm-up required to help prevent injury. This Lat Pulldown Pro should only be used with proper instructions. Always maintain good form and control during exercise. If you feel pain or are unable to maintain good form, stop immediately. Failure to follow these instructions could result in injury.
- Always maintain control of the Handles (Exercise Arms) during exercise. The sudden release of the Exercise Arms during exercise will cause the Exercise Arms to recoil uncontrollably and could result in serious injury or property damage. Bring the Exercise Arms to the start position in a controlled manner to safely end exercise. If at any time you are not able to control the amount of resistance during exercise, push the left ([minus foot pedal]) to reduce the resistance.
- Never perform Power Test without a proper warm-up. This high resistance/high-speed test should only be performed with proper instructions (see page 15 "Power Test" for complete instruction). Always maintain good form and control during the test. If you feel pain or are unable to maintain good form, stop immediately. Failure to follow these instructions could result in injury.
- Never make adjustments to the machine during exercise as this may cause muscle strain. Always return the Exercise Arms to the start position before making any adjustments to help prevent injury.
- The highest level of safety can only be ensured if the equipment is regularly inspected for damage and wear. Always check the equipment before use for proper function and any damaged, worn, or broken parts. Immediately replace damaged, worn, or broken parts. Do not use the Lat Pulldown Pro until all repairs have been completed and tested by a Keiser-certified technician.
- Use only replacement parts supplied/recommended by Keiser Corporation. Attempting to repair or replace any damaged, worn, or broken parts on your own is not recommended. A Keiser-certified technician should be consulted.
- The use of any exercise equipment, including, without limitation, Keiser's strength training equipment in which resistance can be changed at any time during the repetition, without proper instruction and supervision violates the terms of the agreement for the purchase of such products. The ability to add resistance anytime during a repetition, including, without limitation, the ability to do a heavy negative may be dangerous, especially for anyone that does not recognize or respect the potential danger.
- Users, agents, and/or anyone directing the use of the Lat Pulldown Pro shall determine the suitability of the Lat Pulldown Pro for its intended use, and said parties are specifically put on notice that they shall assume all risk and liability in connection herewith.
- If you do not understand these instructions or have doubts about the safety of the installation, assembly, or use of this product, contact Keiser Customer Support: 1 559 256 8000, service@keiser.com, keiser.com/support (Telephone and Live Chat, Monday-Friday 7 am to 5:30 pm PST).
Conventions Used
This Operation Manual contains the following marks:
[WARNING]: Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
[CAUTION]: Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury.
[IMPORTANT]: Indicates information considered critical, but not hazard-related.
Safety and Notification Labels
Label A: Shows resistance settings, set/reps, target reps, peak power indicators.
Label B: Shows a diagram of the Lat Pulldown Pro with instructions for adjusting seat, lap bar, and arm position. Includes a WARNING about unpredictable muscles, tendons, and joints, and resistance during exercise.
Label C: Keiser Corporation address, Made in USA, CE mark, and model/serial number information.
Label D: MADE IN THE USA graphic.
Maintain and do not remove safety or notification labels for any reason. They contain important information. If unreadable or missing, contact Keiser Corporation for a replacement (see back cover for contact information).
Contraindications
There are a number of contraindications in the context of the relevant fields of the Lat Pulldown Pro use. In rehabilitation, only the medical staff can determine the form and extent of therapy. Medications can have an influence on the rehabilitation (e.g. neuroleptics, benzodiazepines, barbiturates, anti-epileptics, etc.). In the following cases, Lat Pulldown Pro training may only be carried out after consultation with a doctor:
- Pregnancy
- Acute thrombosis
- Fresh wounds (e.g. after surgery)
- Artificial joints or prosthetics
- Bone fractures
- Spinal disc damage
- Traumatic injury to the spine
- Diabetes
- Epilepsy
- Inflammation
- Acute migraine headache
- Chronic illnesses
- Cancer
- Acute myocardial infarction or unstable angina pectoris (determined by a stress test)
- Cardiovascular diseases e.g. severe high blood pressure at rest, carditis, congestive heart failure, severe valvular heart disease, dangerous heart arrhythmias at rest, or aortic aneurysm
If the patient is experiencing acute illness, febrile condition (i.e. fever), or newly occurring pain, this represents an absolute contraindication for physical stress. In such situations, it is necessary to postpone training until the patient's health has improved sufficiently.
In some situations (especially in patients with coronary heart disease or lung disease) overstraining can lead to an acute intensification of the patient's symptoms. In such situations, an exercise ECG is essential and training is only possible under medical supervision.
The use of the automated operation (pulse automatic, preset programs, external control via computer or other device) is prohibited, unless the strain was authorized by a physician in accordance with the patient's capacity/health.
For applications in endurance training, diagnostics and performance testing of patients, performance diagnostics, and stress tests, the same contraindications apply (among others) as with all physical stress. If there is doubt, it is important that a physician be consulted before using the Lat Pulldown Pro.
Technical Specifications
Equipment Specifications
See Figure 2 for Lat Pulldown Pro dimensions and weight.
- Resistance Range: 16 - 300 lbs (7 - 136 kg), change resistance in 1 lb/kg increments
- Adjustable Exercise Arms, independent action
- Adjustable Seat and Lap Bar height
- Maximum user weight limit: 441 lbs (200 kg)
Height: 77 inches (1,956 mm)
Width (arms at widest span): 49 inches (1,245 mm)
Depth: 46 inches (1,169 mm)
Base Width: 36 inches (915 mm)
Weight: 204 lbs (93 kg)
Technical Data
Air Storage Tank
The equipment contains two air storage tanks (air accumulator) with the following operating parameters:
| Parameter | Value |
|---|---|
| Maximum working pressure | 125 psi (8.6 bar) |
| Maximum working temperature | 104°F (40°C) |
| Minimum working temperature | 32°F (0°C) |
| Maximum vessel capacity | 68 in³ (1.11 L) per tank |
Power
- 1.5V D Alkaline Batteries (quantity 2, Keiser PN 966500)
- 3V CR2032 Lithium Coin Cell Battery (quantity 1)
Note: The 3V CR2032 battery is permanently attached and not serviceable. Contact Keiser Customer Support for service.
Installation and Placement
No assembly required. Place the Lat Pulldown Pro on a flat, level surface. Make sure the base of the frame makes full contact with the floor. If gaps are present, relocate the equipment to an even surface.
Connect the Equipment to the Keiser Air System
[WARNING]: Never connect equipment to an air source capable of exceeding 120 psi / 8.27 bar. Over pressurizing Keiser pneumatic equipment may cause tubing to burst, breakage of equipment, abnormal operation, or serious injury. Use only clean, dry, regulated compressed air at the rated pressure range of 100-120 psi / 6.89-8.27 bar.
- Plug the Compressor into the appropriate power source to power the Compressor ON (allow the Compressor to build up to a minimum of 100 psi / 6.89 bar; Keiser Compressor and Keiser Air System not included, sold separately).
- Connect the 1/4-inch Quick Disconnect (QD) from the equipment into the Keiser Air Supply (see Figure 3).
Training Space
The equipment footprint is 49 inches x 46 inches (1,245 mm x 1,169 mm) with arms at their widest span. The minimum recommended free space around the equipment is 24 inches (610 mm) for the sides.
Footprint: 49 inches (1,245 mm) wide x 46 inches (1,169 mm) deep.
Minimum recommended free space on sides: 24 inches (610 mm).
Note: Additional Free Space may be required to accommodate mobility device access.
Operation
Equipment Overview
- 1 Exercise Arms
- 2 Handles
- 3 Arm Adjustment Knobs
- 4 Power Display
- 5 Lap Bar
- 6 Adjustable Seat
- 7 Anti-Slip Steps
- 8 Increase/Decrease ([plus foot pedal]/[minus foot pedal]) Foot Pedals
- 9 Processor Box
- 10 Quick Disconnect (QD) with Tube
- 11 Lap Bar Plunger Knob
- 12 Cylinders
- 13 Instruction Placard (not shown)
Power Display
Display Features
Resistance, Reps, and Power workout data output on the Power Display are shown below.
- RESISTANCE: Current resistance setting (lbs or kg).
- REPS: Number of repetitions (0-99).
- PERCENT OF PEAK POWER: The percentage of peak power achieved for the most recent repetition (0-100%).
- PEAK POWER: Displays the highest power output (measured in Watts) that has occurred during your workout.
Also shows indicators for SET/REPS, TARGET REPS, and CHIP/NO CHIP status.
Operation
How to Adjust the Resistance
- Increase the resistance using the Positive ([plus foot pedal]) Foot Pedal.
- Decrease the resistance using the Negative ([minus foot pedal]) Foot Pedal.
How to Reset/Clear Workout Data (Reps, Percent of Peak Power, and Peak Power)
- Press and hold the Foot Pedals simultaneously, release when "CLEr" appears in the RESISTANCE window.
- eChip Users: "CLEr" also deletes the current workout data from the eChip.
System Messages (appear in the RESISTANCE window)
- "OFF" = low-power consumption sleep mode. Sleep mode occurs after 60 seconds of machine inactivity to help prolong battery life. To wake, press either Foot Pedal and resume operation.
- "Lo-bA" (Low Battery) = weak batteries, replace soon. If the batteries are dead (depleted), the Power Display remains blank. See page 17 "Battery Replacement" section for procedure.
Power Display Features with eChip
The Keiser eChip* is an optional digital workout log that records and recalls your workout data. Additional workout data made available when using the Power Display with an eChip are shown below.
- TARGET RESISTANCE/CURRENT POWER: Target resistance is based on the set from your previous visit, changes to Percent of Peak Power after your first rep.
- = SET/REPS: The set count is signaled by three horizontal lines followed by the set number (1-9) and changes to Reps count after your first rep.
- TARGET REPS: Goal based on the set from your previous visit.
- MACHINE ADJUSTMENT: Input machine setting (Seat, Arm), set to set, and recall settings from your previous visit.
- eCHIP READER: Receives and reads eChip data.
- eCHIP: Records workout data.
Operation
How to Record Workout Data on the eChip
- Insert the eChip into the eChip Reader.
- Prepare the machine for your workout:
- Set the Resistance using the [plus foot pedal]/[minus foot pedal] Foot Pedals.
- Input Machine Adjustment setting using the buttons on the display.
- Start your exercise:
- Minimum 3 reps required to record a set.
- Remove and re-insert the eChip to change Set number.
How to Recall Workout Data from the eChip
Insert eChip into the eChip Reader to recall workout data from the corresponding set of your previous visit:
- SET
- TARGET REPS
- TARGET RESISTANCE
- MACHINE ADJUSTMENT (when applicable)
System Notes
- eChip Storage: Up to 24 machine models, up to 240 separate workout sets. Set count range is 1-9, rep count range is 0-99 per machine per visit. A visit is defined as multiple workouts that occur within a four-hour period.
- No workout data ("---") indicates the eChip was not previously utilized on the machine.
- Machine Adjustment: No Machine Adjustment data indicates no data was input to record. Settings can only be changed immediately after the eChip is inserted and before your third rep. After three reps are performed, the setting cannot be changed until the eChip is removed and reinserted. Settings are not saved in Power Tests (Keiser 6-Rep test) mode.
* eChip not included. Contact Keiser Customer Support for order information.
Proper Operation Check
Check equipment condition and function before every workout:
- A. Handles and Exercise Arms: Move freely; Adjustment Knobs engage properly; no loose parts in the linkage system.
- B. Belt and Pulley: Belt is free of excessive wear, rips or tears and Linkage system moves freely with no binding.
- C. Foot Pedals and Display: Press Foot Pedals to check for proper [plus foot pedal] / [minus foot pedal] operation and the Display powers on*.
- D. Upholstery and Lap Bar: No excessive wear, free of rips or tears; Lap Bar and Plunger Knob function properly.
- E. Seat Adjustment: Functions and engages into setting positions properly (tilt up the front end of the Seat).
- F. Stability: Equipment is level to a solid, flat surface.
- G. Air Leaks: No air leaks audible in the system.
Immediately replace damaged, worn, or broken parts. Do not use the Lat Pulldown Pro until all repairs have been completed and tested by a Keiser-certified technician.
* "Lo-bA" = Batteries are low, replace immediately. If batteries are dead (depleted), the Power Display remains blank (see Battery Replacement procedure, page 17).
How to Use the Lat Pulldown Pro
- Adjust the Seat Height: Sit facing the machine and adjust the Seat so your feet are flat on the floor and can reach the Foot Pedals.
- Adjust Arm Position: Use the Adjustment Knobs to set the Handgrips at your extended reach. Ensure both Arms are set to the same position.
- Release the Plunger Knob to adjust the Lap Bar snugly across your thighs.
- Adjust the resistance using the Foot Pedals.
- BICEPS
- RHOMBOIDS
- LATISSIMUS DORSI
How to Use the Lat Pulldown Pro (Continued)
[CAUTION]
- Consult your physician before beginning any exercise program.
- This equipment should only be used with proper instructions.
- Proper warm-up required to help prevent serious injury.
- Always maintain good form and control during exercise.
- If you feel pain, faintness, or are unable to maintain good form, stop immediately.
- Use caution when increasing/decreasing resistance during exercise.
- Never make adjustments to the machine during exercise. Failure to do so could result in serious injury.
Concentric Phase (Downward Movement)
- Pull the elbows down until hands are just at your shoulder height.
- Maintain an upright position with your feet flat on the floor.
Eccentric Phase (Upward Movement)
- Return the Exercise Arms to the start position in a smooth, controlled manner.
- Slower speed during upward movement is recommended.
- Maintain control of the load; keep the Exercise Arms off the stops throughout the exercise.
Breathing
- Exhale during the concentric phase (downward movement).
- Inhale during the eccentric phase (upward movement).
Training Tips
- Ensure your feet rest flat on the ground throughout exercise.
- Maintain the natural curvature of your spine.
- Avoid rocking your body to create momentum when pulling heavy loads.
Power Test
[CAUTION]: Test should only be performed with proper instruction. Never perform Power Test without proper warm-up.
The purpose of the Power Test (KEISER 6-Rep Test) is to determine your RESISTANCE SETTING FOR MAXIMUM POWER. Use your RESISTANCE SETTING FOR MAXIMUM POWER as a baseline measurement to program safe and effective training sessions. The test consists of two sets:
SET 1: Three repetitions, Low resistance, high speed (10% of your maximum)
SET 2: Three repetitions, High resistance, high speed (80-90% of your maximum)
Speed is essential in power output. Perform all repetitions at maximum speed at the given resistance.
Power Test Procedure
Before you begin: Warm-up and estimate your maximum resistance setting. During testing, you can adjust the resistance in either Set before rep "3" if needed (REPS resets to "0"). Note: Test may be performed with or without the eChip inserted.
- START TEST: Press and hold both Foot Pedals, release when "6 r" appears in the RESISTANCE window.
- SET RESISTANCE, LOW LEVEL: Set the resistance to a low level (10% of your maximum).
- POWER TEST, SET 1 ("P1"): Perform one repetition at maximum speed. Pause briefly, then perform two repetitions at maximum speed. "P1" in the TARGET REPS window indicates Power Test, Set 1 initiated.
- SET RESISTANCE, HIGH LEVEL: Increase the resistance to a high level (80-90% of your maximum).
- POWER TEST, SET 2 ("P2"): Perform one repetition at maximum speed. Pause briefly, then perform two repetitions at maximum speed. Note: Test advances to "P2" (Power Test, Set 2).
- TEST RESULT: After your last rep, your RESISTANCE SETTING FOR MAXIMUM POWER value is displayed.
TEST COMPLETE. Exit Power Test to resume normal operation.
How to exit the Power Test: Press and hold the Foot Pedals simultaneously, release when "CLEr" appears in the RESISTANCE window (eChip users: Remove the eChip).
Troubleshoot: "Er" 1 - 4 indicates not enough difference in resistance between the low and high sets. Try again with a greater difference in resistance between the low and high sets. To restart the Power Test at any time, begin at Step 1 (eChip users: Remove and reinsert the eChip before attempting to restart the test).
Maintenance
[CAUTION]: SERVICE AND REPAIR SHALL ONLY BE PERFORMED BY KEISER-CERTIFIED TECHNICIANS. Failure to follow these instructions can result in serious injury.
Preventative Maintenance Schedule
[CAUTION]: THE HIGHEST LEVEL OF EQUIPMENT SAFETY CAN ONLY BE ENSURED IF THE EQUIPMENT IS REGULARLY INSPECTED FOR DAMAGE AND WEAR. Immediately replace damaged, worn, or broken parts. Do not use the Lat Pulldown Pro until all repairs have been completed and tested by a Keiser-certified technician.
- Daily
- Check for safe and proper function of the equipment (perform "Proper Operation Check," page 12).
- Clean the chrome and paint where applicable.
- Wipe down the equipment with a clean cloth. If necessary, use water and mild soap (neutral, non-caustic). Target areas that come in contact with sweat. Wipe dry the equipment.
- Weekly
- Check parts most susceptible to wear are not damaged or broken: Upholstery, Belts, Linkage System, Foot Pedals, and Hand Grips.
- Wax chrome and paint where applicable; wax upholstery.
- Clean Hand Grips.
- Inspect Air Line Filter.
- Monthly
- Check externally visible screws are fastened properly with no looseness.
- Clean and lubricate the Cylinder Rods.
- Inspect Air Line for kinks, tears, or breaks.
- Inspect Frame for any weakening in weld areas, and other connected areas.
- Quarterly
- Lubricate Pivot Bushings.
- Inspect Exhaust Muffler and Air Filter for discoloration; replace if necessary.
- Verify compressor(s) cycle on/off between 100-120 psi (6.89-8.27 bar).
- Annually and other Required Maintenance
- For complete instructions, see page 18 "Annual Maintenance."
- Battery Replacement. The low battery signal ("Lo-bA") will appear on the Power Display when it is time to replace the batteries. Refer to page 17 "Battery Replacement" for complete instructions.
NOTE: Your Keiser Air Compressor (not included with your Lat Pulldown Pro) requires basic annual maintenance. Contact Keiser Customer Support for Air Compressor operator manual or download at keiser.com/support (search: Air Compressor manuals).
[IMPORTANT]: Do not use household or industrial cleaners as they contain caustic chemicals that can destroy the paint finish and cause corrosion. Use only mild soap/detergent (neutral, non-caustic) to clean.
Contact Keiser Customer Support for replacement parts order, or for any matters regarding the safe operation of your Lat Pulldown Pro (see back cover for contact information).
Battery Replacement
Do not operate the equipment during battery replacement procedure. "Lo-bA" = Batteries are low, replace immediately. NOTE: If batteries are dead (depleted), the Power Display remains blank. To replace the batteries, refer to Figure 11 and follow the instructions below. Tools required: #1 and #2 Phillips Screwdrivers.
- Remove the Module Top and Back covers by unscrewing the four small and four large Phillips screws.
- Unscrew the Brass Nut on the Processor Box. Pull and remove the cover.
- Remove the 2 D batteries by carefully pulling out the Battery Sleeve (follow manufacturer's recommendations for handling, maintaining, and disposing of batteries).
- Observe the correct polarity position (see +/- marking inside the battery compartment), insert the 2 new D batteries into the battery sleeve and install.
- The Power Display will enter a brief test sequence (you will see a series of numbers flashing).
- Replace the Processor Box cover and screw the Brass Nut finger tight.
[IMPORTANT]: Once the test sequence ends (numbers stop flashing), press either the increase or decrease Foot Pedal and allow the machine to enter sleep mode ("OFF") to resume normal operation.
[CAUTION]
- Do not dispose of batteries in a fire. The batteries may explode.
- Do not open or mutilate batteries. They contain an electrolyte which is toxic and harmful to the skin and eyes.
- Replace batteries with the same number and type of batteries as originally installed in the equipment.
- Recycle batteries in accordance with local recycling procedures.
Annual Maintenance
The following routine maintenance is recommended annually or at the time batteries are replaced:
- Clean: Wipe any accumulated dust around the Frame and the Linkage System, including the Air Tanks and Cylinders, using a clean shop cloth.
- Visual inspection of the Linkage System: Move freely and no loose parts; all externally visible nuts and bolts are tightened properly.
- Visual inspection of Air Lines and Communication Wires: Air Lines have no kinks, tears, or breaks; Communication Wires have no exposed wires or visible damage.
- Replace the Muffler if discoloration is present: Tool required: 11/16 inch Wrench or Adjustable Wrench.
- Replace the Air Filter if element is dirty (element turns a bright pink or red color): Tools required: #1 and #2 Phillips Screwdriver, Small Needle Nose Pliers, and Cutter Tool (to cut off flared end of tubes). Note: Refer to the Battery Replacement section for guidance on accessing the air filter.
- Lubricate Cylinder Rods: Wipe the Cylinder Rods clean and coat lightly with clean, SAE 30 motor oil, or with a silicon-based spray.
- Visual inspection of moving components: Seat functions properly and the adjustment mechanism engages properly. Check Exercise Arms are fully functional; all externally visible nuts and bolts are tightened properly.
[WARNING]: HIGH-PRESSURE AIR. DISCONNECT THE EQUIPMENT FROM THE AIR SUPPLY AND RELEASE ALL THE AIR IN THE EQUIPMENT ([minus foot pedal]) BEFORE PERFORMING ROUTINE MAINTENANCE.
Contact Keiser Customer Support for replacement part(s) order, or for any matters regarding the safe operation of your Lat Pulldown Pro (see back cover for contact information).
Regulatory and Compliance Notices
Marks: [CE Mark]
Safety Notifications
Displayed watts testing parameters: "Current Power," "Peak Power," and "Percent of Peak Power" are not suitable for use in applications where the health and safety of a patient may be dependent on the accuracy of those parameters.
Physiotherapy Settings Note: In physiotherapy settings, patients may operate this equipment in accordance with this user manual and the instructions and guidance provided by the healthcare personnel responsible for supervising their treatment and care. However, patients shall not perform preventive maintenance, repairs or replace batteries on equipment installed in physiotherapy facilities.
| TYPE/DEGREE OF PROTECTION | CLASSIFICATION/IDENTIFICATION/WARNINGS | SYMBOL |
|---|---|---|
| The degree of protection against electric shock | Device is powered by two D cell alkaline batteries. | N/A |
| The degree of protection against the ingress of liquids | Not protected | N/A |
| The degree of safety in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide | Not suitable | N/A |
| The mode of operation | Continuous | N/A |
| Information regarding potential electromagnetic or other interference and advice regarding avoidance | The Lat Pulldown Pro uses electromagnetic and RF energy only for its internal function. Therefore, its EMC and RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. | N/A |
| EMC Notices, Statement of Compliance | See Electromagnetic Compatibility (EMC) section, page 20. | N/A |
| ID of specified optional external power supplies or battery chargers | The Lat Pulldown Pro does not require an external power supply. | N/A |
| ID of any risks associated with the disposal of waste products, residues, including disposal of the equipment itself at the end of its useful life | The Lat Pulldown Pro contains electronic circuit assemblies, 2 alkaline D cell batteries, and a sealed lithium coin cell battery that may require compliance with specific local disposal or recycling procedures. | N/A |
| The specification of the environmental conditions of transport and storage | Use indoor in climate-controlled environment only. Keep away from areas of extreme humidity. NOTICE: Equipment not tested at extreme high/low temperatures. | N/A |
Electromagnetic Compatibility (EMC)
EMC Notices – Statement of Compliance
This product has been determined to be compliant with the applicable standards, regulations, and directives for the countries where the product is marketed.
Compliance documentation, such as Declaration of Compliance for the product, are available upon request by contacting service@keiser.com. Please include the product, model number identifiers, and serial number and country that compliance information is needed for in request.
Korea: This equipment is for home use and has acquired electromagnetic conformity registration, so it can be used not only in residential areas but also other areas.
US FCC Compliance Statement
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Disposal
This equipment contains electrical or electronic components, alkaline batteries, and a sealed lithium coin cell battery that must be disposed of properly to comply with the EU Directive on disposal of waste electrical and electronic equipment (EU WEEE Directive 2002/96/EC).
Contact an appropriate waste disposal company upon the equipment's end of service life. Disposal must be in accordance with respective national regulation.
Wear parts: After being replaced, wear parts must be disposed of according to country-specific waste laws.
If you have any questions about equipment disposal, please contact your local dealer or Keiser Customer Support (see back cover for contact information).
Warranty Statement
View or print your Lat Pulldown Pro warranty online at keiser.com/support/warranty.
If you have any questions about your warranty, please contact Keiser Customer Support at 1 559 256 8000 and via live chat at keiser.com/support (Monday-Friday, 7 am to 5:30 pm PST), or by email at service@keiser.com.
Customers outside the United States may obtain warranty information directly through a Keiser international distributor or dealer in the country of installation, or direct from Keiser's international division.
European Authorized Representative
KEISER EUROPE SP. Z O.O.
ul. Starodworska 1
Gdańsk 80-137
Polska
UK Responsible Person (UKRP)
KEISER UK Ltd.
Unit 3, Hampton Industrial Estate
Hampton St., Tetbury
Gloucestershire, GL8 8LD