Instruction Manual for LED LINEAR models including: Variocanopy Square Mounting Set, Square Mounting Set, Mounting Set, Set
Drivers & Controls: LED Linear™
File Info : application/pdf, 9 Pages, 738.88KB
DocumentDocumentLED LinearTM GmbH Dr. Alfred-Herrhausen-Allee 20 47228 Duisburg Germany Phone +49 2065 94322-100 Fax +49 2065 94322-120 Germany@led-linear.com Fagerhult Lighting Ltd 3334 Dolben Street SE1 0UQ London United Kingdom Phone +44 207 403 4123 light@fagerhult.co.uk VARIOCANOPY SQUARE MOUNTING SET DECKENLEUCHTE | CEILING LUMINAIRE Erforderliches Werkzeug | Required tools 3 4 MONTAGEANLEITUNG INSTALLATION INSTRUCTIONS © LED Linear GmbH / Alle Rechte und Änderungen vorbehalten. All rights reserved, subject to change / Technical amendments and graphical presentation are subject to change. Edition 02/2022 Art. # 33100057 PENDELLEUCHTE | PENDANT LUMINAIRE Erforderliches Werkzeug | Required tools 3 4 Allgemeine Sicherheitshinweise · Lesen Sie die Anleitung vor Montage und Inbetriebnahme. · Übergeben Sie die Anleitung dem Kunden zur Aufbewahrung. · Entfernen Sie nicht das Typenschild der Leuchte. · Beachten Sie die nationalen Installations- und Unfallverhütungsvorschriften bei der Montage. Die Installation darf nur von einer geschulten elektrotechnischen Fachkraft durchgeführt werden. · Beschädigte Leitungen dürfen nur von geschultem elektrotechnischen Fachpersonal gewechselt werden. · Bei unsachgemäßer Montage oder nachträglicher Änderung an der Leuchte wird keine Haftung übernommen. · Die Lichtquelle dieser Leuchte darf nur vom Hersteller oder einem von ihm beauftragten Servicetechniker oder einer vergleichbar qualifizierten Person ersetzt werden. · LED-Leuchtmittel (ohne IP67 Schutz) dürfen nicht gereinigt werden. · Reinigen Sie die Leuchte regelmäßig mit einem angefeuchteten weichen Tuch. Benutzen Sie nur lösungsmittelfreie Reinigungsmittel. Achtung, vorher Netzversorgung trennen und System abkühlen lassen. · Zum Schutz der Oberflächen vor Schmutz und Fingerabdrücken empfehlen wir das Tragen von Schutzhandschuhen während der Montage. · Die Entsorgung des Systems muss über die Entsorgung von Elektronikprodukten erfolgen gemäß der EU-Richtlinie-WEEE (Waste Electronical and Electronic Equipment). · Zur Beantwortung von technischen Rückfragen steht Ihnen unser Projektmanagement bzw. unsere weltweiten Niederlassungen und Distributoren zur Verfügung. Bitte richten Sie Ihre Anfrage an info@led-linear.com. Netzspannung / Anschluss · Überprüfen Sie die Spannungsfreiheit des Systems vor Montage und Wartung. Achtung Stromschlaggefahr! · Setzen Sie nur Konverter mit geeigneter Netzspannung ein. · Der Betrieb der Leuchte mit veränderten oder beschädigten Anschlussleitungen ist nicht zulässig. · Unterbrechen Sie bei einer Dreiphaseninstallation nicht den Neutralleiter der elektronischen Betriebsgeräte. · Stromgetriebene (Constant Current) LED-Module dürfen sekundärseitig nicht geschaltet werden. · Vermeiden Sie Überspannung an den elektronischen Betriebsgeräten. · Die Anschlussleitung darf den Lichtausstrahlungsbereich nicht verdecken. · Verbinden und Trennen der Leuchte und des Betriebsgeräts unter anliegender Netzspannung kann zu Beschädigungen der Komponenten führen. · Nicht zueinander passende Leuchten und Betriebsgeräte können sich gegenseitig beschädigen. · Falsch gepolte Leitungen beschädigen die Leuchte. · Die Installation einer Dali Anlage darf nur von geschulten Fachkräften durchgeführt werden. Achten Sie auf die eventuell erforderliche Netzspannungsfestigkeit des Dali-Betriebsgeräts. · Für den Dimmbetrieb sind nur geeignete Dimmer einzusetzen. Beachten Sie die Herstellerangaben. Nicht geeignete Dimmer können das Gesamtsystem beschädigen. · Zum Anschluss der Leuchte an das Versorgungsnetz sind Anschlussklemmen in Übereinstimmung mit EN 60998-2-1 oder EN 60998-2-2 zu verwenden. Umgebung · Achten Sie auf die bestimmungsgemäßen Umgebungsbedingungen, unter denen die Leuchte betrieben werden darf. · Installieren Sie die Leuchte an einem Ort, an der sie nicht direkter Sonneneinstrahlung oder Wärme- quellen ausgesetzt wird. · Achten Sie darauf, dass die Einbauvariante nicht mit Dämmmaterial abgedeckt wird. · Decken Sie Leuchte und Betriebsgerät wegen Überhitzungsgefahr nicht ab. · Achten Sie auf den Mindestabstand zwischen Leuchte und beleuchtetem Objekt. · Achten Sie bei Deckenbefestigung der Leuchte auf die zulässigen Deckenlasten. · Außenbeleuchtung sollte nur nach Sonnenuntergang bis zum Sonnenaufgang betrieben werden. Achtung: LEDs nicht berühren. Bruchempfindlich! Elektrostatische Entladungen können die LEDs beschädigen. Attention: Do not touch LEDs. Fragile! Electrostatic discharges can damage the LEDs. General Safety Instructions · Read the instructions for installation and commissioning. · Pass the instructions to the customer for safekeeping. · Do not remove the type plate of the luminaire. · Please note the national installation and accident prevention regulations during installation. The installation must be performed only by a trained electrical specialist. · Damaged cables may only be changed by trained electrical personnel. · For improper installation or any subsequent change to the luminaire no liability is accepted. · The light source of this lamp may be replaced only by the manufacturer or an authorized service technician or a similarly qualified person. · LED lamps (without IP67 protection) must not be cleaned. · Clean the luminaire regularly with a smooth damp cloth. Only use solvent-free cleaning agents. Attention: previously cut off the mains supply and allow system to cool down. · To protect the surface from dirt and fingerprints, we recommend the use of protective gloves during installation. · The disposal of the system must be carried out on the disposal of electronic products in accordance with the EU Directive WEEE (Waste Electronical and Electronic Equipment). · In order to answer technical queries, please contact our project management respectively our worldwide branches and distributors. Please send your request to info@led-linear.com. Mains voltage / connection · Check that there is no voltage of the system prior to installation and maintenance. Beware of electric shock! · Only use converters of the correct voltage. · It is not allowed to use the luminaires with altered or damaged connector cables. · In case of a three-phase installation do not interrupt the neutral conductor of the electronic ballasts. · Electrically operated (Constant Current) LED modules must not be secondary side connected. · Avoid overvoltage at the electronic control gear. · The cable must not cover the light-emitting portion. · Connecting and disconnecting the luminaire and the control gear under present voltage can cause damage to the components. · Mismatched luminaires and control gears can damage each other. · Wrongly polarized cables damage the luminaire. · The installation of a Dali system may only be performed by trained personnel. Pay attention to any necessary mains voltage resistance of the Dali operating device. · Only suitable dimmers must be used for dimming. Observe the manufacturer`s instructions. Not suitable dimmers can damage the whole system. · Terminals in accordance with EN 60998-2-1 or EN 60998-2-2 must be used for connecting the lamp to the power grid. Environment · Pay attention to the allowable ambient conditions under which the luminaire may be operated. · Install the luminaire in a place where it is not exposed to direct sunlight or heat sources. · Ensure that the recessed version is not covered with insulating material. · Do not cover luminaire and control gear to prevent overheating. · Pay attention to the minimum distance between luminaire and lighted object. · Be careful with allowable floor loads in case of ceiling mounting of the luminaire. · Exterior lighting should be used only after sunset until sunrise. Printed on VIVUS 89 MADE IN GERMANY Recycling DECKENMONTAGE DECKENLEUCHTE 1.11.18 CEILING MOUNTING CEILING LUMINAIRE DECKENMONTAGE PENDELLEUCHTE 2.12.22 CEILING MOUNTING PENDANT LUMINAIRE © LED Linear GmbH / Alle Rechte und Änderungen vorbehalten. All rights reserved, subject to change / Technical amendments and graphical presentation are subject to change. Edition 02/2022 4 x Torx M3 x 6mm 2 x Torx M3 x 10 mm 2 x Torx M3 x 12mm 1 x Torx M4 x 5mm Mutter | Screw nut M4 Art. # 16000347 Montagerahmen Mounting frame 1 1 1 2 4 5 6 7 77 7 Befestigungspunkte Attachment points 1 Steuerung Control gear 2 Deckenbefestigung Ceiling mounting 2 3 Blockklemme Block clamp 3.2 3 3 3.1 3.1 Erdungsschraube earthing screw 6 2 3.2 Zugentlastung 7 strain relief 7 4 Drahtseil Wire rope 5 Kabeldurchgang Cable passage 6 Deckenhalter (Pendel) Ceiling bracket (Pendant) 7 EVG PSU 1.1 1.2 Optionale Bohrlöcher Optionale Bohrlöcher ! Optional drill holes Optional drill holes AUS OFF 1.3 1.4 © LED Linear GmbH / Alle Rechte und Änderungen vorbehalten. All rights reserved, subject to change / Technical amendments and graphical presentation are subject to change. Edition 02/2022 1.5.1 1.6.1 3 12.7.2.1 1.5.2 Befestigungspunkt Drahtseil Attachment point Wire rope 4 SEPARAT ERHÄLTLICH SEPARATELY AVAILABLE 1.6.2 Befestigungspunkte EVG Attachment points PSU EVG PSU 7 7 77 7 7 12.7.2.2 Befestigungspunkte Blockklemme Attachment points Block clamp Blockklemme Block clamp 3 3 CLICK CLICK 12.8.2.1 4 1.9.1 SEPARAT ERHÄLTLICH SEPARATELY AVAILABLE 3 1.10.1 12.8.2.2 Befestigungspunkte Erdungsschraube und Zugentlastung Attachment points earthing screw and strain relief Blockklemme Block clamp 3.2 3.1 Steuerung Control gear 1.9.2 Befestigungspunkte Steuerung Attachment points Control gear 1 1 1 1.10.2 Kabeldurchgang Cable passage 5 © LED Linear GmbH / Alle Rechte und Änderungen vorbehalten. All rights reserved, subject to change / Technical amendments and graphical presentation are subject to change. Edition 02/2022 1.21.12.1 3 1.11.2 Befestigungspunkte Decke Attachment Ceiling 2 2 2 1.12 Blockklemme Block clamp L N DA+ DA- Braun Brown Blau Blue Gelb-Grün Yellow-Green 12.1.23 Kabel Leuchte Cable Luminaire 12.1.24 12.1.25 © LED Linear GmbH / Alle Rechte und Änderungen vorbehalten. All rights reserved, subject to change / Technical amendments and graphical presentation are subject to change. Edition 02/2022 ! Bitte beachten Sie die Anleitung des Herstellers Please follow the manufacturer`s instructions 12.1.26 1.17 ! AN ON 3 1.18 OK 2.1 ! AUS OFF 2.3 2.2 Optionale Bohrlöcher Optional drill holes 2.4 © LED Linear GmbH / Alle Rechte und Änderungen vorbehalten. All rights reserved, subject to change / Technical amendments and graphical presentation are subject to change. Edition 02/2022 2.5.1 22.6.2.1 3 2.5.2 Befestigungspunkt Drahtseil Attachment point Wire rope 4 SEPARAT ERHÄLTLICH SEPARATELY AVAILABLE 22.6.2.2 Befestigungspunkte EVG Attachment points PSU EVG PSU 7 7 77 7 7 © LED Linear GmbH / Alle Rechte und Änderungen vorbehalten. All rights reserved, subject to change / Technical amendments and graphical presentation are subject to change. Edition 02/2022 22.7.2.1 22.8.2.1 4 2.9.1 SEPARAT ERHÄLTLICH SEPARATELY AVAILABLE 3 2.10.1 22.7.2.2 Befestigungspunkte Blockklemme Attachment points Block clamp Blockklemme Block clamp 3 3 CLICK CLICK 22.8.2.2 Befestigungspunkte Erdungsschraube und Zugentlastung Attachment points earthing screw and strain relief Blockklemme Block clamp 3.2 3.1 Steuerung Control gear 2.9.2 Befestigungspunkte Steuerung Attachment points Control gear 1 1 1 2.1.02.2 Deckenhalter (Pendel) Ceiling bracket (Pendant) Deckenhalter (Pendel) Ceiling bracket (Pendant) 6 6 2.11.1 2.11.2 Kabeldurchgang Cable passage 5 2.12.1 2.12.2 Befestigungspunkte Decke Attachment Ceiling 2 2 2 3 2.13 Blockklemme Block clamp L N DA+ DA- Braun Brown Blau Blue Gelb-Grün Yellow-Green 22.1.24 Kabel Leuchte Cable Luminaire 22.1.25 22.1.26 © LED Linear GmbH / Alle Rechte und Änderungen vorbehalten. All rights reserved, subject to change / Technical amendments and graphical presentation are subject to change. Edition 02/2022 ! Bitte beachten Sie die Anleitung des Herstellers Please follow the manufacturer`s instructions © LED Linear GmbH / Alle Rechte und Änderungen vorbehalten. All rights reserved, subject to change / Technical amendments and graphical presentation are subject to change. Edition 02/2022 22.1.27 22.1.29 2.21 ! AN ON 2.18 22.2.20 22.2.22 3 OK