Instructions for THORN models including: Basicdim Ild Programmer, Basicdim Ild, Programmer
basicDIM ILD ThebasicDIM ILDprovidesthebasisforaneasy-to-useandcost-effectivelightingsystem withmotion detection. Whenthesensordetectsmovementittriggersaindividualadjustablemotiondetectionprofileinthecontrol unit.Astheamountofnaturalambientlightchangestheilluminancefrom theartificiallightingsystem is adjusted. Theconnectedluminariescanbeswitchedonandoffviaremotecontrol. Switch-on delay Thisisthetimeafterwhichthelightingisswitchedoffaftertheswitchdelay.Itcanbesetviathe"timedelay" parameter Secondlightvalue OnthebasicDIM ILDyoucansetwhetherthelightistobeswitchedoffaftertheswitchdelayordimmedto thesecondlightvalue.Thelightvalueandthedwelltime(howlongthevaluecanbeheld)canbesetviathe "whenvacant"and"sec.level"parameters. Bright-out Ifthenominalluminance(eg500lux)isexceededfor10minutesbymorethan150% (e.g.750lux)thelighting isswitchedoffevenifthemotionisdetected.Thelightingisswitchedonagainwhenthemeasuredlightvalue fallsbelowthesetpoint.Thebright-outfunctionisdisplayedbyagreenstatusindicationLEDatthesensor. Bright-offdelay Ifthesystem isswitchedoffmanuallyviatheremotecontrolthemotionsensorisdeactivatedattheendofa 10minutesdelayifmotionhasnotbeendetectedthemotionsensorisactivatedagain.Ifthesensordetects motionduringthe"ManualOff"delay,thetimewillberesettothestart.