LED SOLUTION 16W LED Light with Motion Sensor and Battery Backup (Model 191049)
Product Overview
This fixture is fully automatic, switched on by a motion sensor, and equipped with a backup power module, allowing continuous lighting in case of a power outage. The fixture features an energy-efficient LED source for economical operation.
Specifications
| Feature | Specification | Feature | Specification |
|---|---|---|---|
| Voltage | 110-240 V / AC | Detection angle | Ceiling 360° ? |
| Operating frequency | 50/60 Hz | Detection distance | Max. 6 m ? |
| Light sensitivity setting | <3-2000 LUX (adjustable) ⚙️ | Operating temperature | -20 ~ +40 °C ?️ |
| Lighting time | Min. 10 s ± 3 s to Max. 3 min ± 30 s ⏱️ | Operating humidity | < 93% RH ? |
| Power | 16 W | Installation height | 2.2 - 4 m ? |
| Luminous flux | 1100 lm | Battery | 3.7 V / 1500 mAh Li-ion ? |
| Backup light power | 1.2 W | Detectable speed | 0.6 - 1.5 m/s ? |
| Luminous flux of the backup light | 65 lm | Backup period | Up to 5 hours (if fully charged) |
| Power factor | >0.5 | Dimensions | Diameter - 290mm, Height - 60mm |
| IP rating | IP20 |
Functionality
This light fixture is equipped with a backup power source. In the event of a power outage, the backup light will be illuminated from the battery, providing uninterrupted lighting for up to 5 hours. The light can be switched on during both day and night. The user can set the desired light level for activation.
The light will turn on when motion is detected during the day if the "SUN" (max) position is set. Conversely, it is possible for the light to turn on only in complete darkness - at a light level of 3 LUX, if the "MOON" (min) position is set.
The lighting duration can be set using the second controller. If the set duration elapses and no further motion is detected by the sensor, the light will turn off. It will turn on again with new motion.
Setting the lighting duration: The user can adjust the duration of lighting activation. The minimum duration is 10 seconds ± 3 seconds, and the maximum duration is 3 minutes ± 30 seconds. ⏱️
Installation
- Turn off the power supply. ⚡
- Unscrew the plastic ring around the sensor and remove the diffuser. [Illustration shows the diffuser and surrounding ring being detached.]
- Thread the supply wire through the cable gland in the luminaire.
- Screw the luminaire using three screws into pre-drilled holes with anchors. [Illustration shows the luminaire being mounted with screws and anchors.] ?
- Make the wire connections according to the wiring diagram. [Diagram shows electrical connection points.] ?
- Connect the wires from the battery to the connector. [Illustration shows battery wires connecting to a terminal.] ?
- Attach the diffuser and screw on the plastic ring.
- You can now turn on the power supply. ⚡
Diagram Information:
- Detection angle: 360° ceiling coverage. ?
- Maximum detection distance: 6 meters. ?
- Recommended installation height: 2.2 to 4 meters. ?
- Sensor detection range: Indicated as a 3-meter by 3-meter square area. ?
Testing
To test during the day, set the TIME knob to the minimum (-) position and the LUX knob to the maximum (SUN ☀️) position. Turn on the power supply. ⚡ The light will not function immediately; it requires approximately 30 seconds of warm-up.
When the motion sensor detects movement, the light will turn on. Once motion stops, it will turn off after the set time. ⏱️
To test darkness activation, turn the LUX knob to the minimum (MOON ?) position. If the ambient light level is higher than 3 LUX, the light will not turn on. If the ambient light drops to 3 LUX (DARK), the sensor will activate and the light will illuminate. If there is no motion within the sensor range, the light will turn off after the set time.
In the event of a power outage, the emergency module will activate automatically, and the light will continuously illuminate in emergency mode for up to 5 hours. ?
Notes
- If performing the test during the day, set the controller to the "SUN" ☀️ position; otherwise, the light fixture will not function.
- Installation should only be carried out by a person with electrical qualifications. ⚡
- Obstacles within the sensor's detection range can negatively affect detection functions. ?
- Do not install the light fixture near sources of heat or airflow, such as heaters or air conditioners. ?️?
Troubleshooting
- Light is not turning on: ❓
- Check if the light is properly connected. ?
- Verify if the power supply is functional. ⚡
- Ensure that the LUX control is correctly set. ⚙️
- PIR sensor sensitivity is poor: ❓
- Check if there are any obstacles in the sensor's detection field. ?
- Verify if the ambient air temperature is not too high. ?️
- Make sure you are moving within the PIR sensor's detection field. ?
- Sensor does not automatically turn off: ❓
- Check if there is continuous motion in the detection field. ?
- Verify if the TIME control is not set to a too long duration. ⏱️