COMET

Dataloggers - Uxxxx family

QUICK START MANUAL

PRODUCT DESCRIPTION

The COMET Uxxxx dataloggers are equipped with a two-part self-locking terminal block and are designed for measuring and recording physical and electrical quantities with an adjustable logging interval from 1 second to 24 hours. Measured values, or average and min/max values over a recording interval, are stored in internal non-volatile memory. Data logging can be cyclic (overwriting oldest data when full) or non-cyclic (stopping when full). The devices also evaluate alarm states, such as exceeding or falling below measured value limits, memory filling, or technical defects. Alarm signaling can be visual (display symbol or LED blink) or acoustic. Data recording can be continuous or triggered by alarms. The devices are powered by an internal replaceable lithium battery.

Device setting, recorded data downloading, and online monitoring are carried out using the COMET Vision software installed on a computer. The USB interface is used for computer communication. The website www.cometsystem.com provides access to the software.

Available Models and Measured Values:

Device type Measured values Construction
U0246 3x Tc + 1x Te + 1x Ti + 2x cc Terminal block for connection of three thermocouples and one external Pt1000/0 probe
U0541 2x Te + Tdiff + 2xU + 2x cc Terminal block for connection of two external Pt1000/0 probes and two voltage inputs
U5841 3xU + BIN + 3x cc Terminal block for connection of three voltage inputs and one binary input
U6841 3xI + BIN + 3x cc Terminal block for connection of three current inputs and one binary input
U7844 4x BIN Terminal block for connection of four binary inputs (two of them can work as a counter)

Key: Tc... Thermocouple, Te... External temperature, Ti... Internal temperature, Tdiff... temperature difference, U... Voltage 0-10V, I... Current 0-20 mA, BIN... Binary inputs, cc... calculated channel (used to calculate and record values based on selected formulas).

INSTALLATION AND OPERATION

Mounting

Fasten the datalogger on the wall using two screws or insert it into the optional wall holder LP100. The device can also be operated as a portable unit, ensuring it is protected from falling and maintained in a proper working position.

Connect Input Cables

Set-up the Device

Device setup is performed using a computer with Windows 7 or higher. Minimum hardware requirements are a 1.4 GHz processor and 1 GB of memory.

Operating the Device from the Keypad

The devices do not require special maintenance. COMET SYSTEM recommends regular verification of measurement accuracy through calibration.

Technical Specifications

U0246 U0541 U5841 U6841 U7844
Device type Pt1000 probe, thermocouple Pt1000 probe, thermocouple
Power batteries lithium battery 3,6 V / 2200 mAh
Recording interval (1, 2, 5, 10, 15, 30) s (1, 2, 5, 10, 15, 30) min (1, 2, 3, 4, 6, 8, 12, 24) h
Memory capacity 500 000 values in non-cyclic record mode, 350 000 values in cyclic record mode
Temperature measuring range -200 to +260°C -200 to +260°C - - -
Accuracy of temperature measurement according to the type, ± 0.2°C* according to the type, ± 0.2°C* - - -
DC voltage measuring range - 0 to 10 V 0 to 10 V - -
Accuracy of DC voltage measurement - ± 10 mV ± 10 mV - -
DC current measuring range - - - 0 to 20 mA -
Accuracy of DC current measurement - - - ± 20 µA -
Binary input configured for dry contact Contact resistance for the „switched-on" state: < 10 kΩ Contact resistance for the „switched-on" state: < 10 kΩ Contact resistance for the „switched-on" state: < 10 kΩ Contact resistance for the „switched-on" state: < 10 kΩ Contact resistance for the „switched-on" state: < 10 kΩ
Binary input configured for voltage measurement Input voltage range: 0 to 30 V Input voltage range: 0 to 30 V Input voltage range: 0 to 30 V Input voltage range: 0 to 30 V Input voltage range: 0 to 30 V
Excitation voltage - approx. 3V approx. 3V - approx. 3V
Input voltage for the „L" level < 0.8 V < 0.8 V < 0.8 V < 0.8 V < 0.8 V
Input voltage for the „H" level > 2.0 V > 2.0 V > 2.0 V > 2.0 V > 2.0 V
Minimum state duration necessary for latching the state 1 s 1 s 1 s 1 s 1 s
Recommended calibration interval 2 years 2 years 2 years 2 years 2 years
Protection class IP20 IP20 IP20 IP20 IP20
Temperature operating range -30 to +70°C -30 to +70°C -30 to +70°C -30 to +70°C -30 to +70°C
Relative humidity operating range (no condensation) 0 to 100%RH 0 to 100%RH 0 to 100%RH 0 to 100%RH 0 to 100%RH
Working position any position any position any position any position any position
Recommended storage temperature (5 - 90%RH, no condensation) -20 to +45°C -20 to +45°C -20 to +45°C -20 to +45°C -20 to +45°C
Electromagnetic compatibility according to EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1 EN 61326-1
Weight 130 g 130 g 130 g 130 g 130 g

* The accuracy of the device without probe in the range of -200 to +100 °C is ±0.2 °C (in the temperature range of +100 to +260 °C, accuracy is ±0.2% of measured value).

** Thermocouple types: „J", "K", "S", "B", "T", "N", see "Instruction manual" for details.

Dimensions

The device dimensions are approximately 86 mm (width) x 93 mm (height) x 32 mm (depth). The SP013 tool, designed for WAGO connectors, is also depicted.

Connection Diagrams

U0246

Inputs IN1, IN2, IN3 are for Thermocouples (Tc). Input IN4 is for an External Temperature probe (Pt1000). The diagram shows typical connections for thermocouple probes and a Pt1000 probe.

U0541

Inputs IN1, IN2 are for External Temperature probes (Pt1000). Inputs IN3, IN4 are for Voltage measurements (0-10 V). The diagram illustrates connections for Pt1000 probes and voltage inputs.

U5841

Inputs IN1, IN2, IN3 are for Voltage measurements (0-10 V). Input IN4 is a Binary input (BIN). The diagram shows connections for voltage inputs and a binary input.

U6841

Inputs IN1, IN2, IN3 are for Current measurements (0-20 mA). Input IN4 is a Binary input (BIN). The diagram illustrates connections for current inputs and a binary input.

U7844

Inputs IN1, IN2, IN3, and IN4 are Binary inputs (BIN). Inputs IN3 and IN4 can also function as counters (BIN/CNT). The diagram shows connections for binary inputs, indicating the potential for counter functionality.

SAFETY INSTRUCTIONS

Models: U0246, U0541, U5841, U6841, U7844, U0246 Data Logger, U0246, Data Logger, Logger

File Info : application/pdf, 2 Pages, 1.11MB

PDF preview unavailable. Download the PDF instead.

ie-lgr-n-uxxxx-c-04

References

Microsoft Word 2013

Related Documents

Preview COMET Wx8xxP Series SIGFOX Transmitters: Instructions for Use
User manual for COMET Wx8xxP series SIGFOX network transmitters. Learn about installation, operation, technical parameters, and maintenance for models measuring temperature, humidity, voltage, and pulse counts.
Preview COMET Wx8xxP SIGFOX IoT Sensors: Quick Start Guide
Quick start guide for COMET Wx8xxP series SIGFOX IoT sensors, detailing product features, setup procedures, mounting instructions, safety precautions, and technical specifications for temperature, humidity, voltage, and pulse counting.
Preview Comet GP-15 Antenna Instruction Manual: High Gain Triple Band Ground Plane
This manual provides instructions for the Comet GP-15, a high-gain triple-band ground plane antenna designed for ham radio use on 52.5, 146, and 446 MHz frequencies. It covers features, specifications, assembly, and precautions.
Preview COMET IoT Sensor plus Wx8xx Series: Instructions for Use
Comprehensive guide for COMET's Wx8xx series IoT sensors, covering installation, operation, technical specifications, and safety precautions for temperature, humidity, atmospheric pressure, and CO2 monitoring via the SIGFOX network.
Preview COMET A8205 Rechargeable Battery Replacement Procedure
Step-by-step instructions for replacing the COMET A8205 internal Li-Ion rechargeable battery in COMET dataloggers, including safety warnings and charging guidelines.
Preview Comet Disinfecting Cleaner with Bleach - Concentrate Safety Data Sheet
Safety Data Sheet for Comet Disinfecting Cleaner with Bleach - Concentrate, including identification, hazards, composition, first aid, fire-fighting measures, accidental release measures, handling and storage, exposure controls, physical and chemical properties, stability and reactivity, toxicological information, ecological information, disposal considerations, transport information, and regulatory information.
Preview Comet UHV-6 Multi Band Mobile Antenna Operation Manual
This operation manual provides comprehensive details for the Comet UHV-6 Multi Band Mobile Antenna. It covers features, specifications, frequency adjustment procedures, wiring examples with duplexers, maintenance guidelines, and customer support information for amateur radio operators.
Preview Commeter C3633 Digital Thermometer-Hygrometer Instruction Manual
Comprehensive instruction manual for the Commeter C3633 digital thermometer-hygrometer, detailing its features, technical specifications, operation, battery replacement, and support information.