LS XGF-SOEA Programmable Logic Controller Installation Guide
File info: application/pdf · 2 pages · 811.08KB
12
경고 주의
Oct 15, 2024 — 제품 설치 시 아래 순서에 따라 설치하여 주시기 바랍니다. 1) 제품의 장착. ① 모듈 밑 쪽의 고정용 돌기를 베이스의. 모듈 고정용 홀에 삽입합니다.
Extracted Text
C/N: 10310000989 PCr/oNg:r1a0m31m0a0b00le98L9ogic Controller
XGT Sequence of Event
XGF-SOEA
PLC . .
1
/
. . , , , Short, .
. . . . , . . . .
2
.
No
1
055
2
-2570
3
595%RH,
4
595%RH,
-
5f<8.4
-
3.5mm
5
8.4f150
9.8(1g)
-
5f<8.4
-
1.75mm
X,Y, Z
10
8.4f150
4.9(0.5g)
-
-
IEC 61131-2
3
.
1) XGI CPU
: V3.8
2) XGK CPU
: V4.2
3) XGR CPU
: V2.5
4) XG5000 Software
: V3.68
4 (mm)
.
6
SOE .
1Mbit
: PLC :
()
: 1ms(: �2ms) : 1ms(: �0.5ms)
32(/ )
32 On/off U 512(16)
7
1) . 2) , , AWG22(0.3) .. 3) . 4) .. 5) , .
1) 0.3~2, (0.3) . 2) . 3) , 100 . 4) , PLC . 5) . 6) DC 24V AC 110V AC 220V . 7) IRIG-B AWG24(0.2) , . 8) , IRIG-B SOE . 9) Signal Ground Noise . RS-422 Isolator Noise . Isolator , 100 , SOE . 10) Isolator .
8
36. . , .
1) , (, , CAP, , LCD ) 2) �� 3) 4) 5) 6) � 7) , 8) . .
5
. 1) . . . 2) . . . .
LS ELECTRIC Co., Ltd. www.ls-electric.com 10310000989 V4.5 (2024.06)
!
( )
1544-2080
TEL:(02)2034-4623~38
TEL:(051)310-6855~60
TEL:(053)603-7741~8
() TEL:(062)510-1891~92
() TEL:(042)820-4240~42
FAX:(02)2034-4057 FAX:(051)310-6851 FAX:(053)603-7788 FAX:(062)526-3262 FAX:(042)820-4298
(): 4 56 ( 31226)
C/N: 10310000989
Programmable Logic Controller Installation Guide
XGT Sequence of Event
XGF-SOEA
This installation guide provides simple function information of PLC control. Please read carefully this data sheet and manuals before using products. Especially read safety precautions and handle the products properly.
1 Safety Precautions
Meaning of warning and caution inscription
WARNING
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices.
WARNING
Do not contact the terminals while the power is applied. Protect the product from being gone into by foreign metallic matter. Do not manipulate the battery(charge, disassemble, hitting, short, soldering).
CAUTION
Be sure to check the rated voltage and terminal arrangement before wiring. When wiring, tighten the screw of terminal block with the specified torque range. Do not install the flammable things on surroundings. Do not use the PLC in the environment of direct vibration. Except expert service staff, do not disassemble or fix or modify the product. Use the PLC in an environment that meets the general specifications contained
in this datasheet. Be sure that external load does not exceed the rating of output module. When disposing of PLC and battery, treat it as industrial waste.
2 Operating Environment
To install, observe the below conditions.
No
Item
Specification
Standard
1 Ambient temp.
0 ~ 55
-
2 Storage temp.
-25 ~ 70
-
3 Ambient humidity
5 ~ 95%RH, non-condensing
-
4 Storage humidity
5 ~ 95%RH, non-condensing
-
Occasional vibration
-
-
Frequency Acceleration
5f<8.4
-
3.5mm
5
Vibration Resistance
8.4f150 9.8(1g)
-
Continuous vibration
Frequency Frequency Frequency
5f<8.4
-
1.75mm
8.4f150 4.9(0.5g)
-
10 times in each IEC 61131-2
direction for
X, Y, Z
3 Applicable Support Software
For system configuration, the following version is necessary.
1) XGI CPU
: V3.8 or above
2) XGK CPU
: V4.2 or above
3) XGR CPU
: V2.5 or above
4) XG5000 Software
: V3.68 or above
4 Parts name and Dimension (mm)
This is front part of the CPU. Refer to each name when driving the system. For more information, refer to user manual.
Hold the module by both hands and press
the fixed hook of module thoroughly. By pressing the hook, pull the upper
part of module from the axis of the lower
part of module. By lifting the module upward, remove
the fixed projection of module from the fixing hole.
6 Performance Specifications
Performance specifications are as follows.
Item
Specification
Memory capacity
1Mbit
Event time
Internal time: PLC time External time: External time server time
Resolution(accuracy)
Internal time: 1ms(accuracy: �2ms) External time: 1ms(accuracy: �0.5ms)
Input point
32 points(Sync/source type)
Additional functions
32 points input On/Off state U-device display
Max no. of contacts
512points(16module)
7 Wiring
Precaution for wiring 1) Do not place AC power line near to the module's external input signal line. It should be farther than minimum 100mm between both lines in order not to be affected by noise and magnetic field. 2) Cable shall be selected in due consideration of ambient temperature and allowable
current, whose size is not less than the max. cable standard of AWG22 (0.3).
3) Do not place the cable too close to hot device and material or in direct contact with oil for long, which will cause damage or abnormal operation due to short-circuit.
4) Check the polarity when wiring the terminal. 5) Wiring with high-voltage line or power line may produce inductive hindrance causing
abnormal operation or defect.
6) Use the cable of AWG24(0.3) above with twisted and shielded when communicating
RS-422 by IRIG-B. 7) Determine the cable max. length and node by Timeserver specification of RS-
422(IRIG-B). 8) In case the signal ground of Timeserver isn't isolated, use the RS-422 isolator because
of the noise. The transit delay of the isolator must be within 100.
9) Do not use the isolator which has the function with analyzing the data signal and sending it.
Wiring Example 1) The size of I/O device cable is limited to 0.3~2 mm2 but it is recommended to select a size(0.3 mm2) to use conveniently 2) Please isolate input signal line from output signal line.. 3) I/O signal lines should be wired 100mm and more away from high voltage/high current main circuit cable. 4) Batch shield cable should be used and the PLC side should be grounded unless the main circuit cable and power cable can't be isolated. 5) When applying pipe-wiring, make sure to firmly ground the piping. 6) The output line of DC24V should be isolated from AC110V cable or AC220V cable.
8 Warranty
The warranty period is 36 months from the date of manufacture. The initial diagnosis of faults should be conducted by the user. However, upon request, LS ELECTRIC or its representative(s) can undertake this task for a fee. If the cause of the fault is
found to be the responsibility of LS ELECTRIC, this service will be free of charge. Exclusions from warranty
1) Replacement of consumable and life-limited parts (e.g. relays, fuses, capacitors, batteries, LCDs, etc.)
2) Failures or damages caused by improper conditions or handling outside those specified in the user manual
3) Failures caused by external factors unrelated to the product 4) Failures caused by modifications without LS ELECTRIC's consent 5) Use of the product in unintended ways 6) Failures that cannot be predicted/solved by current scientific technology at the time
of manufacture 7) Other cases for which LS ELECTRIC is not responsible
For detailed warranty information, please refer to the user's manual.
The content of the installation guide is subject to change without notice for product performance improvement.
5 Installing / Removing Modules
Here describes the method to attach each product to the base or remove it. 1) Installing module Slide the upper part of module to fix to the base, and then fit it to the base by using the module fixed screw. Pull the upper part of module to check if it is installed to the base completely. 2) Removing module Loosen the fixed screws of the upper part of module from the base.
LS ELECTRIC Co., Ltd. www.ls-electric.com 10310000989 V4.5 (2024.06)
� E-mail: automation@ls-electric.com
� Headquarter/Seoul Office
Tel: 82-2-2034-4033,4888,4703
� LS ELECTRIC Shanghai Office (China)
Tel: 86-21-5237-9977
� LS ELECTRIC (Wuxi) Co., Ltd. (Wuxi, China)
Tel: 86-510-6851-6666
� LS-ELECTRIC Vietnam Co., Ltd. (Hanoi, Vietnam)
Tel: 84-93-631-4099
� LS ELECTRIC Middle East FZE (Dubai, U.A.E.)
Tel: 971-4-886-5360
� LS ELECTRIC Europe B.V. (Hoofddorf, Netherlands)
Tel: 31-20-654-1424
� LS ELECTRIC Japan Co., Ltd. (Tokyo, Japan)
Tel: 81-3-6268-8241
� LS ELECTRIC America Inc. (Chicago, USA)
Tel: 1-800-891-2941
� Factory: 56, Samseong 4-gil, Mokcheon-eup, Dongnam-gu, Cheonan-si, Chungcheongnam-
do, 31226, Korea