ORTECH VENTILATION FAN
Models: ODE-5004, ODE-8007, ODE-9010
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
- Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
- Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
- Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
- Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
- When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
- Ducted fans must always be vented to the outdoors.
- Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit (ceiling installation only).
- This unit must be grounded.
CAUTION
- For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
- This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. DO NOT MOUNT THIS PRODUCT IN A WALL.
- Do not let plaster dust or any other construction residue enter the fan. During construction or renovation, cover the fan.
- Combustible products used for cleaning such as acetone, alcohol, ether, or benzol are highly explosive and should never be used close to the fan.
CLEANING & MAINTENANCE
The ventilation fan should be cleaned regularly (internally and externally) to preserve its appearance and performance. Use a dusting brush attachment to gently vacuum the exterior and interior of the ventilation fan to remove dust and debris.
OPERATION
Use an on/off switch to operate this fan. See "Connect Wiring Diagram" for details.
PLAN THE INSTALLATION
- Do not use in a cooking area.
- Two ways to connect ductwork to a factory-shipped unit.
Illustration shows two duct connection options: a roof cap with damper and a wall cap with damper. It advises short duct runs, sealing gaps around the fan housing and duct joints. Insulation around the housing is recommended. A 'COOKING AREA' is marked with a warning not to install above or inside it.
ASSEMBLY INSTRUCTIONS
1. MOUNT HOUSING TO JOIST OR I-JOIST
a. Hold the housing so that it is in contact with the bottom of the joist.
b. Attach the housing with four (4) screws to the joist through the holes in each mounting flange.
Diagram shows the fan housing being attached to a joist or I-joist using four screws through the mounting flanges.
2. Mount with additional mounting holes
The interior of the fan housing contains additional mounting holes in case exterior mounting is not possible. Screw or nail the fan housing directly to the framing or joists. Remove the blower assembly as directed in the service parts section of this manual to gain access to the additional mounting holes.
Illustration of the fan housing interior, highlighting additional mounting hole locations for alternative installation methods.
3. Install DUCT AND BLOWER ASSEMBLY
a. Install duct from the inside of the housing; Fix the duct by the tab.
b. Fix the BLOWER ASSEMBLY to the housing by 3 screws.
Diagram depicts installing the ductwork from inside the housing and securing the blower assembly to the housing with three screws.
4. INSTALL ROUND DUCTWORK
a. Connect the round ductwork (not included) to the damper/duct connector, and run the ductwork to a roof or wall cap (not included).
b. Using tape (not included), secure all the ductwork connections so that they are air tight.
c. Insulated flexible duct is recommended for the quietest possible installation. If rigid duct is used, a short (1-3 feet) section of insulated flexible duct will ensure quiet operation.
The ducting from this fan to the outside of building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated air flow.
Illustration of round ductwork connection to a damper/duct connector, leading to a roof or wall cap. Emphasizes airtight connections and recommends insulated flexible duct for quiet operation.
CONNECT ELECTRICAL WIRING
Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the wiring plate. Refer to the wiring diagram, and connect the wires as shown.
Schematic shows 120V AC power connecting to a switch box, then to the fan unit. Wire connections are color-coded: Black (Line/Fan), White (Neutral), Ground (Ground). Components include ON/OFF SWITCH, FAN, UNIT, SWITCH BOX, and POWER SUPPLY.
INSTALL GRILLE
Install ceiling material to complete the ceiling construction and cut around the fan housing.
To attach the grille assembly to the fan housing, pinch the grille springs on the sides of the grille assembly and position the grille into the housing with the grille springs in the appropriate slots. Push the grille assembly towards the ceiling to secure.
Illustration of grille installation. Shows pinching the grille springs and inserting them into the housing slots, then pushing the grille towards the ceiling to secure it.
SERVICE PARTS
| PART | PART NAME | Qty. |
|---|---|---|
| 1 | Grille Assembly (includes part 2) | 1 |
| 2 | Grille Spring | 2 |
| 3 | Blower | 1 |
| 4 | Blower Wheel | 1 |
| 5 | Motor | 1 |
| 6 | Motor Plate | 1 |
| 7 | Housing | 1 |
| 8 | Wire Panel / Harness Assembly | 1 |
| 9 | Duct/Duct Connector | 1 |
| a | Screw | 3 |
| b | Screw | 3 |
| c | Screw | 3 |
* Blower Assembly includes parts 3, 4, 5, 6, a, b.
Replacement installation: Remove the screw (part a), then take out the blower assembly from the housing (part 7). Replace the broken parts.
WARNING: Ensure that the fan is switched off from the supply mains before replacing.
Exploded view diagram of the ventilation fan components, with each part numbered (1-9) and screws labeled (a-c) corresponding to the Service Parts list.
WARRANTY
THREE YEAR LIMITED WARRANTY from the original date of purchase against defects in material and workmanship. This warranty is limited up to the amount of the original purchase price of the product, excluding any labor cost. For inquiries please visit www.ortechindustries.ca or call 1-888-543-6473.
Installer: Leave this manual with the homeowner. Visit www.ortechindustries.ca for more information.