User Manual for TEKNOLINE models including: TSIP-24 IP Tuner to IP Gateway, TSIP-24, IP Tuner to IP Gateway, IP Gateway

NDS3224 MPEG4/AVC H

Jerry Luo

Gözat

[TSIP-24 IP] IP DVB-S/S2 IPTV STREAMER QAM MODULATOR


File Info : application/pdf, 16 Pages, 1.83MB

PDF preview unavailable. Download the PDF instead.

tsip-24ip24-tuner-to-ip-gateway-users-manual-2022526 20220
TSIP-24 IP Tuner to IP Gateway User's Manual

CHAPTER 1 PRODUCT OUTLINE..................................................................................................1
1.1 Outline............................................................................................................................................................ 1 1.2 Features .......................................................................................................................................................... 1 1.3 Inner Principle ............................................................................................................................................... 2 1.4 Specifications .................................................................................................................................................. 2 1.5 Appearance and Description .......................................................................................................................... 3
CHAPTER 2 INSTALLATION GUIDE ............................................................................................ 5
2.1 Acquisition Check .......................................................................................................................................... 5 2.2 Installation Preparation ................................................................................................................................. 5 2.3 Wire's Connection .......................................................................................................................................... 7
CHAPTER 3 WEB NMS OPERATION ............................................................................................ 8
3.1 login ................................................................................................................................................................ 8 3.2 Operation ....................................................................................................................................................... 8
CHAPTER 4 TROUBLESHOOTING ............................................................................................ 15 CHAPTER 5 PACKING LIST .......................................................................................................... 16

TSIP-24 IP Tuner to IP Gateway User's Manual
Chapter 1 Product Outline
1.1 Outline
TSIP-24 IP Tuner to IP Gateway is a head-end interface conversion device which supports MPTS and SPTS output switchable. It supports 24 MPTS or 512 SPTS output over UDP and RTP/RTSP protocol. It is integrated with tuner demodulation (or ASI input) and gateway function, which can demodulate the signal from 24 tuners into IP package, or directly convert the TS from ASI input and tuner into IP package, then output the IP package through different IP address and ports. BISS function is also embedded for tuner input to descramble your tuner input programs.
1.2 Features
 Support 24 FTA DVB- S/S2/S2X input, 1 ASI input  Support BISS descrambling  Support DisEqc function  24 MPTS or 512 SPTS output (MPTS and SPTS output switchable)  2 GE output (IP address and port number of GE1 and GE2 are different), up to
850Mbps---SPTS  2 independent GE output port, GE1 + GE2---MPTS  Support PID filtering, re-mapping (Only for SPTS output)  Support "Null PKT Filter" function (Only for MPTS output)  Support Web operation
1

1.3 Inner Principle

TSIP-24 IP Tuner to IP Gateway User's Manual

1.4 Specifications

Input Tuner Section

24 tuners input +1 ASI input---SPTS/MPTS output

DVB-S DVB-S2 DVB-S2X

Frequency In Symbol rate Signal Strength FEC Constellation Max input bitrate Frequency In Symbol rate
FEC
Constellation Max input bitrate Frequency In Symbol rate
FEC
2

950-2150MHz 0.5~45Msps - 65- -25dBm 1/2, 2/3, 3/4, 5/6, 7/8 QPSK 125 Mbps 950-2150MHz QPSK/8PSK /16APSK :0.5~45 Msps 32APSK: 0.5~34Msps; QPSK: 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10 8PSK: 3/5, 2/3, 3/4, 5/6, 8/9, 9/10 16APSK: 2/3, 3/4, 4/5, 5/6, 8/9, 9/10 32APSK: 3/4, 4/5, 5/6, 8/9, 9/10 QPSK, 8PSK, 16APSK, 32APSK 125 Mbps 950-2150MHz QPSK/8PSK /16APSK :0.5~45 Msps 8APSK: 0.5~40Msps 32APSK: 0.5~34Msps QPSK: 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10, 13/45, 9/20, 11/20 8PSK: 3/5, 2/3, 3/4, 5/6, 8/9, 9/10 8APSK: 5/9-L, 26/45-L 16APSK: 2/3, 3/4, 4/5, 5/6, 8/9, 9/10, 1/2-L, 8/15-L, 5/9-L, 26/45, 3/5, 3/5-L, 28/45, 23/36 , 2/3-L, 25/36, 13/18, 7/9, 77/90

TSIP-24 IP Tuner to IP Gateway User's Manual

BISS Descrambling Output
System
Miscellaneous

Constellation Max input bitrate

32APSK: 3/4, 4/5, 5/6, 8/9, 9/10, 2/3-L, 32/45, 11/15, 7/9 QPSK, 8PSK, 8APSK, 16APSK, 32APSK 125 Mbps

Mode 1, Mode E (Up to 850Mbps) (descramble individual program)

512 SPTS IP mirrored output over UDP and RTP/RTSP protocol through GE1 and GE2

port (IP address and port number of GE1 and GE2 are different) , Unicast and Multicast

24 MPTS IP output (for Tuner/ASI pass-through) over UDP and RTP/RTSP protocol

through GE1 and GE2 port, Unicast and Multicast , 2 ASI output

Web based management

Ethernet software upgrade

Dimension

482mm×410mm×44mm (W×L×H)

Approx weight Environment

3.6kg 0~45(work)-20~80Storage

Power requirements

100~240VAC, 50/60Hz

Power consumption

20W

1.5 Appearance and Description

Front Panel Illustration:

1

ASI input port

2

ASI output port

3

Data portGE1&GE2: IP out port

4

NMS port: Network management interface

5

USB port for upgrade

6

Power indicator

3

TSIP-24 IP Tuner to IP Gateway User's Manual
Rear Panel Illustration
1 24 channels RF IN Interface 2 Integrated power switch and socket 3 Grounding Wire
4

TSIP-24 IP Tuner to IP Gateway User's Manual

Chapter 2 Installation Guide

2.1 Acquisition Check
When users open the package of the device, it is necessary to check items according to packing list. Normally it should include the following items:  TSIP-24 IP Tuner to IP Gateway  Grounding Cable  RF In and Loop Out Cable  Power Cord If any item is missing or mismatching with the list above, please contact local dealer.
2.2 Installation Preparation
When users install device, please follow the below steps. The details of installation will be described at the rest part of this chapter. Users can also refer rear panel chart during the installation. The main content of this chapter including:  Checking the possible device missing or damage during the transportation  Preparing relevant environment for installation  Installing gateway  Connecting signal cables
 Connecting communication port (if it is necessary)
2.2.1 Device's Installation Flow Chart Illustrated as following

Acquisition Check

Fixing Device

Connecting Grouding Wire and
Power Cord

Connecting Signal Wire

Setting Parameter

Running Device

2.2.2 Environment Requirement
5

TSIP-24 IP Tuner to IP Gateway User's Manual

Item Machine Hall Space
Machine Hall Floor

Requirement When user installs machine frame array in one machine hall, the distance between 2 rows of machine frames should be 1.2~1.5m and the distance against wall should be no less than 0.8m. Electric Isolation, Dust Free Volume resistivity of ground anti-static material: 1X107~1X1010Grounding current limiting resistance: 1M

(Floor bearing should be greater than 450Kg/)

Environment Temperature Relative Temperature Pressure Door & Window Wall Fire Protection
Power

5~40(sustainable )0~45(short time) installing air-conditioning is recommended
20%~80% sustainable 10%~90% short time
86~105KPa Installing rubber strip for sealing door-gaps and dual level glasses for window It can be covered with wallpaper, or brightness less paint. Fire alarm system and extinguisher Requiring device power, air-conditioning power and lighting power are independent to each other. Device power requires AC power 100V-240V 50/60Hz 2A. Please carefully check before running.

2.2.3 Grounding Requirement

 All function modules' good grounding designs are the basis of reliability and stability of devices. Also, they are the most important guarantee of lightning arresting and interference rejection. Therefore, the system must follow this rule.
 Coaxial cable's outer conductor and isolation layer should keep proper electric conducting with the metal housing of device.
 Grounding conductor must adopt copper conductor in order to reduce high frequency impedance, and the grounding wire must be as thick and short as possible.
6

TSIP-24 IP Tuner to IP Gateway User's Manual
 Users should make sure the 2 ends of grounding wire well electric conducted and be antirust.
 It is prohibited to use any other device as part of grounding electric circuit  The area of the conduction between grounding wire and device's frame should be no less
than 25mm2.
2.2.4 Frame Grounding
All the machine frames should be connected with protective copper strip. The grounding wire should be as short as possible and avoid circling. The area of the conduction between grounding wire and grounding strip should be no less than 25mm2.
2.2.5 Device Grounding
Connecting the device's grounding rod to frame's grounding pole with copper wire.
2.3 Wire's Connection
The grounding wire conductive screw is located at the right end of rear panel, and the power switch, fuse, power supply socket is just beside ,whose order goes like this, power switch is on the left ,power supply socket is on the right and the fuse is just between them.  Connecting Power Cord
User can insert one end into power supply socket, while insert the other end to AC power.  Connecting Grounding Wire
When the device solely connects to protective ground, it should adopt independent way, say, share the same ground with other devices. When the device adopts united way, the grounding resistance should be smaller than 1. Caution: Before connecting power cord to TSIP-24 IP Tuner to IP Gateway, user should set the power switch to "OFF".
7

TSIP-24 IP Tuner to IP Gateway User's Manual
Chapter 3 WEB NMS operation
User can only control and set the configuration in computer by connecting the device to web NMS Port. User should ensure that the computer's IP address is different from the TSIP-24's IP address; otherwise, it would cause IP conflict.
3.1 login
The default IP of this device is 192.168.0.136. Connect the PC and the device with net cable, and use ping command to confirm they are on the same network segment. I.G. the PC IP address is 192.168.99.252, we then change the device IP to 192.168.99.xxx (xxx can be 0 to 255 except 252 to avoid IP conflict). Use web browser to connect the device with PC by inputting this device's IP address in the browser's address bar and press Enter. It displays the Login interface as Figure-1. Input the Username and Password (Both the default Username and Password are "admin".) and then click "Login" to start the device setting.

3.2 Operation

Figure-1

Summary  Status
When we confirm the login, it displays the status interface as Figure-2

8

TSIP-24 IP Tuner to IP Gateway User's Manual

User can click any item here to enter the corresponding interface to check information or set the parameters.

System information Figure-2

Parameter Tuner input (DVB-S2/S2X)
From the menu on top side of the webpage, click "Tuner", it displays the interface where users can check the 24 DVB-S/S2/S2X Tuners input status. (Figure-4)

24 DVB-S-S2-S2X Tuner input status

Parameter Program Parse

Figure-4

From the menu on top side of the webpage, click "program Parse", it displays the interface

where users can check the 24 tuner parse status. (Figure-5)

9

TSIP-24 IP Tuner to IP Gateway User's Manual
Figure-5
Parameter BISS
From the menu on left side of the webpage, clicking "BISS", it displays the interface where users can configure BISS and descramble the input channels (Figure-6).
Figure-6
Users can set BISS parameter through click "Add" button.
10

TSIP-24 IP Tuner to IP Gateway User's Manual
Parameter  Output:
From the menu on left side of the webpage, clicking "Output", it displays the interface where users can choose 24 DVB-S/S2/S2X Tuner input and 1 ASI Input programs to output from IP. (Figure-7 and Figure-8)
Operation Area
Figure-8
Figure-9
11

TSIP-24 IP Tuner to IP Gateway User's Manual
System  Network:
Clicking "Network", it displays the interface as Figure-10 where to set network parameters.

Set NMS IP address, the default IP address is 192.168.0.136

Set GE1 IP address

Set GE2 IP address

System  Password:

Figure-10

From the menu on left side of the webpage, clicking "Password", it displays the screen as

Figure-11 where to set the login account and password for the web NMS.

Figure-11
12

TSIP-24 IP Tuner to IP Gateway User's Manual
System  Configuration:
From the menu on left side of the webpage, clicking "Configuration", it displays the screen as Figure-12 where to save /restore/Factory Set/Backup/Load your configurations.

System  Firmware:

Figure-12

From the menu on left side of the webpage, clicking "Firmware", it displays the screen as

Figure-13 where to update firmware for the device.

Select IP output Mode, click "Apply" and reboot the device then the new mode can start to work.
Figure-13
13

TSIP-24 IP Tuner to IP Gateway User's Manual
System  Date/time:
From the menu on left side of the webpage, clicking "Date/time", it displays the screen as Figure-14 where to update Date and time information for the device.

System  Log:

Figure-14

From the menu on left side of the webpage, clicking "Log", it displays the screen as

Figure-14 where to log information for the device.

Figure-15
14

