COMMON TERMINAL BLOCK ACS Series
MANUAL
CE UL Listed
Safety Precautions
Thank you very much for selecting Autonics products. For your safety, please read the following before using.
General Safety Instructions
Please keep these instructions and review them before using this unit.
Please observe the following for safety.
- ⚠️ Warning: Serious injury may result if instructions are not followed.
- ❗ Caution: Product may be damaged, or injury may result if instructions are not followed.
- The following is an explanation of the symbols used in the operation manual:
- ⚠️ Caution: Injury or danger may occur under special conditions.
Warning
- In case of using this unit with machinery (Ex: nuclear power control, medical equipment, ship, vehicle, train, airplane, combustion apparatus, safety device, crime/disaster prevention equipment, etc.) which may cause damages to human life or property, it is required to install a fail-safe device. Failure to do so may cause a fire, human injury or damage to property.
- Do not repair or check units during power on. Failure to do so may cause a fire or electric shock.
- Do not use this unit in places where there are flammable or explosive gas, humidity, direct ray of the sun, radiant heat, vibration, impact etc. Failure to do so may cause a fire or explosion.
- Do not disassemble and modify this unit. Please contact Autonics if it is required. Failure to do so may cause a fire, electric shock, or damage to the product.
Caution
- This unit shall not be used outdoors. It may shorten the life cycle of the product or cause electric shock.
- Please observe the rated specifications. Failure to do so may shorten the life cycle of the product and cause a fire.
- When cleaning the unit, do not use water or organic solvents. Use a dry cloth. Failure to do so may cause electric shock or damage to the product.
- Do not allow dust or wire dregs to enter the unit. Failure to do so may cause a fire or malfunction.
Précautions pour la sécurité (French Safety Precautions)
Après avoir lu ce guide, s'il vous plaît, placez-le dans un lieu où vous pouvez récemment le trouver.
S'il vous plaît suivre les conseils suivants pour la sécurité.
- ⚠️ Avertissement: L'inaccomplissement des instructions peut provoquer des blessures graves.
- ❗ Précaution: Le produit peut être endommagé ou provoquer des blessures si les consignes ne sont pas respectées.
- La signification des icones utilisées dans le produit et le manuel sont les suivants:
- ⚠️ Précaution: Blessure ou danger peuvent se produire dans des conditions particulières.
Avertissement
- Utilisez le produit seulement après avoir relié un double dispositif de sécurité pour les instruments qui ont un grand effet pour le corps humain et la propriété, comme sont les dispositifs d'énergie atomique, mets en oeuvre Médecine, de véhicules, Rails, aéronefs, Brûleurs ou produits de sécurité. L'inaccomplissement peut causer des incendies, lésions personnelles ou dommages à la propriété.
- Ne pas réparer ou vérifier le produit tout alimenté. L'inaccomplissement peut provoquer un incendie ou des décharges électriques.
- Utilisez le produit avec l'environnement comme il est décrit dans le manuel. Évitez le lieu d'émission de gaz corrosifs, gaz inflammables, incorporation température, haute humidité, vibrations, choc, etc. L'inaccomplissement peut provoquer un incendie ou une explosion.
- Ne pas démonter et modifier cet appareil. S'il vous plaît nous contacter si cela est nécessaire. L'inaccomplissement pourrait causer des décharges électriques, incendies, lésions personnelles ou dommages à le produit.
Précaution
- Cette unité ne doit pas être utilisé à l'extérieur. Peut raccourcir le cycle de vie du produit ou causer un choc électrique.
- S'il vous plaît respecter les spécifications nominales. L'inaccomplissement peut raccourcir le cycle de vie du produit et provoquer un incendie.
- Dans nettoyer l'appareil, n'utilisez pas d'eau ou de solvants organiques. Et utiliser un chiffon sec. L'inaccomplissement peut donner lieu des décharges électriques ou des dommages au produit.
- Ne pas laisser de poussière pénétrer l'unité. Cela pourrait provoquer un incendie ou un dysfonctionnement.
Ordering Information
| Model | Item | Terminal type | Number of terminals | Common type |
|---|---|---|---|---|
| ACS-20L | Common terminal block | Screw | 20EA | Left-Right Common |
| ACS-20T | 20EA | Top-Bottom Common | ||
| ACS-40L | Common terminal block | Screw | 40EA | Left-Right Common |
| ACS-40T | 40EA | Top-Bottom Common | ||
| ACS-50L | Common terminal block | Screw | 50EA | Left-Right Common |
| ACS-50T | 50EA | Top-Bottom Common |
Applicable Crimp Terminal
Diagram Description: Illustrates the dimensions for applicable crimp terminals. The 'Forked' type and 'Round' type terminals are shown with dimensions labeled A and B. Applicable wire range is AWG 22-16 (0.30 to 1.25mm²).
| Terminal Type | Dimension A (mm) | Dimension B (mm) | Applicable Wires |
|---|---|---|---|
| Forked | Min. 4.1 - Max. 16.0 | Min. 3.0 - Max. 5.9 | AWG 22-16 (0.30 to 1.25mm²) |
| Round | Min. 4.1 - Max. 16.0 | Min. 3.0 - Max. 5.9 |
Note: Use UL certified crimp terminals.
Installation
1. Mounting to and Removing from DIN rail
Mounting
- Push the rail lock in the direction [up arrow].
- Hook the DIN rail connector onto the DIN rail.
- Push the unit down in the direction [down arrow] and then push up the rail lock to secure the unit body.
Removing
- Insert a screwdriver into the hole of the rail lock and pull the lock out in the direction [left arrow].
- Remove the unit by pulling it in the direction [left arrow].
Diagram Description: Illustrates the process of mounting and removing the terminal block from a DIN rail. It shows the rail lock, DIN rail, and DIN rail connector.
2. Mounting to Panel
This unit can be mounted on a panel using the provided mounting holes.
It is recommended to use M3×30mm screws with spring washers and flat washers of diameter ø6.
The tightening torque should be 0.5 to 0.7 N·m.
Diagram Description: Shows panel mounting holes and indicates the use of screws and washers for panel installation.
Dimensions
Diagram Description: Detailed dimensional drawings for the ACS Series terminal blocks, showing overall dimensions and mounting hole specifications in millimeters (mm).
ACS-20L(T)
Diagram Description: Shows the overall dimensions and mounting hole details for the ACS-20L(T) model. Key dimensions include length, height, and depth.
| Dimension | Value (mm) |
|---|---|
| Overall Length | 62.5 |
| Height | 80 |
| Depth | 39.7 |
| Terminal Pitch | 7.59 |
| Mounting Hole Diameter | ø3.5 (x2) |
| Screw Size | 20-M3 |
ACS-40L(T) / ACS-50L(T)
Diagram Description: Shows the overall dimensions and mounting hole details for the ACS-40L(T) and ACS-50L(T) models. Key dimensions include length, height, and depth.
| Dimension | ACS-40L(T) (mm) | ACS-50L(T) (mm) |
|---|---|---|
| A (Length) | 150 | 184 |
| B (Height) | 89 | 104 |
| C (Depth) | 45.8 | 48.9 |
| D (Base Width) | 39.7 | 34.8 |
| Mounting Hole Diameter | ø3.5 (x2) | ø3.5 (x2) |
| Screw Size | 40-M3 | 50-M3 |
Specifications
| Model | ACS-20L / ACS-20T | ACS-40L / ACS-40T | ACS-50L / ACS-50T |
|---|---|---|---|
| Rated voltage | Max. 125VDC, 125VAC 50/60Hz | ||
| Rated current | Max. 10A | ||
| Common type | Left+COM, Right-COM / Top+COM, Bottom-COM | Left+COM, Right-COM / Top+COM, Bottom-COM | Left+COM, Right-COM / Top+COM, Bottom-COM |
| Number of terminals | 20EA | 40EA | 50EA |
| Terminal pitch | 7.0mm | ||
| Applicable wires | AWG 22-16 (0.30 to 1.25mm²) | ||
| Insulation resistance | Min. 1,000MΩ (at 500VDC megger) | ||
| Dielectric strength | 600VAC 50/60Hz for 1 minute | ||
| Vibration | 0.75mm amplitude at frequency of 10 to 55Hz (for 1 min.) in each of X,Y,Z directions for 2 hours | ||
| Shock | 150m/s² (15G) in each of X, Y, Z directions for 3 times | ||
| Ambient temp. | -15 to 55°C, Storage: -25 to 65°C | ||
| Ambient humi. | 35 to 85%RH, Storage: 35 to 85%RH | ||
| Material | CASE: MPPO, TERMINAL PIN: Brass | ||
| Tightening torque | 0.5 to 0.6 N·m | ||
| Approval | CE, UL Listed | ||
| Weight*¹ | Approx. 92g (Approx. 61g) | Approx. 157g (Approx. 115g) | Approx. 189g (Approx. 141g) |
*¹: The weight is with packaging and the weight in parentheses is only unit weight. Environment resistance is rated at no freezing or condensation.
Wire Connections
Diagram Description: Illustrates the terminal numbering and connection polarity (+/-) for each model. The dot line indicates specific terminals for the ACS-50T model.
ACS-20L
Terminals: B1-B10 (+), A1-A10 (+). Common connections indicated by '+' and '-' symbols.
ACS-20T
Terminals: B1-B10 (+), A1-A10 (+). Common connections indicated by '+' and '-' symbols.
ACS-40L
Terminals: B1-B20 (+), A1-A20 (+). Common connections indicated by '+' and '-' symbols.
ACS-50L
Terminals: B1-B25 (+), A1-A25 (+). Common connections indicated by '+' and '-' symbols.
ACS-40T / ACS-50T
Terminals: B1-B25 (+), A1-A25 (+). Common connections indicated by '+' and '-' symbols. Dot line part is only for ACS-50T model.
Caution for Using
- This unit shall not be used beyond the specified temperature or humidity range.
- Maintain voltage fluctuations in the power supply within the specified range.
- When connecting PLC or other controllers, check the polarity of power and COMMON before wiring.
- Use AWG 16 (1.25mm²) wire and applicable crimp terminals to the terminal block.
- Turn OFF the power supply before wiring.
- Do not use this unit in the following places:
- Places where there is severe vibration or impact.
- Places where strong alkalis or acids are used.
- Places where there is direct ray of the sun.
- Places where strong magnetic field or electric noise are generated.
- Installation environment:
- Shall be used indoors.
- Altitude: Max. 2,000m.
- Pollution Degree: 2.
- Installation Category: II.
It may cause malfunction if above instructions are not followed.
Major Products
- Photoelectric sensors
- Fiber optic sensors
- Door sensors
- Door side sensors
- Area sensors
- Proximity sensors
- Pressure sensors
- Rotary encoders
- Connector/Sockets
- Temperature controllers
- Temperature/Humidity transducers
- SSR/Power controllers
- Counters
- Timers
- Panel meters
- Tachometer/Pulse (Rate) meters
- Display units
- Sensor controllers
- Switching mode power supplies
- Control switches/Lamps/Buzzers
- I/O Terminal Blocks & Cables
- Stepper motors/drivers/motion controllers
- Graphic/Logic panels
- Field network devices
- Laser marking system (Fiber, CO₂, Nd:YAG)
- Laser welding/soldering system
Company Information
Autonics Corporation
Satisfiable Partner For Factory Automation
HEAD QUARTERS:
116, Ungbigongdan-gil, Yangsan-si, Gyeongsangnam-do, Korea
OVERSEAS SALES:
#402-404, Bucheon Techno Park, 655, Pyeongcheon-ro, Wonmi-gu, Bucheon, Gyeonggi-do, Korea
TEL: 82-32-610-2730 / FAX: 82-32-329-0728
E-mail: sales@autonics.com
For product improvement and development proposals: product@autonics.com
Document Model: AS-KE-01-T0002E
Models: ACS-20L, ACS Series Common Terminal Block, Common Terminal Block, Terminal Block, ACS-20T, ACS-40L, ACS-40T, ACS-50L, ACS-50T