Instruction Manual for Autonics models including: ACS-20L, ACS Series Common Terminal Block, Common Terminal Block, Terminal Block, ACS-20T, ACS-40L, ACS-40T, ACS-50L, ACS-50T
AUTONICS ACS-40T (01) PDF MANUAL - MANUAL-HUB.COM
File Info : application/pdf, 1 Pages, 1.16MB
DocumentDocumentCOMMON TERMINAL BLOCK ACS Series M A N U A L Ordering information Model ACS-20L ACS-20T ACS-40L ACS-40T ACS-50L ACS-50T Item Terminal type Common terminal block Screw Number of terminals Common type 20EA 40EA 50EA Left-Right Common Top-Bottom Common Left-Right Common Top-Bottom Common Left-Right Common Top-Bottom Common Applicable crimp terminal B A B A C D C D Thank you very much for selecting Autonics products. For your safety, please read the following before using. Caution for your safety Please keep these instructions and review them before using this unit. Please observe the following for safety. Warning Serious injury may result if instructions are not followed. Caution Product may be damaged, or injury may result if instructions are not followed. The following is an explanation of the symbols used in the operation manual. Caution: Injury or danger may occur under special conditions. Warning 1. In case of using this unit with machinery (Ex: nuclear power control, medical equipment, ship, vehicle, train, airplane, combustion apparatus, safety device, crime/disaster prevention equipment, etc) which may cause damages to human life or property, it is required to install fail-safe device. It may cause a fire, human injury or damage to property. 2. Do not repair or check units during power on. It may cause a fire or electric shock. 3. Do not use this unit in place where there are flammable or explosive gas, humidity, direct ray of the sun, radiant heat, vibration, impact etc. It may cause a fire or explosion. 4. Do not disassemble and modify this unit. Please contact us if it is required. It may cause a fire, electric shock, or damage to the product. Caution 1. This unit shall not be used outdoors. It may shorten the life cycle of the product or cause electric shock. 2. Please observe the rated specifications. It may shorten the life cycle of the product and cause a fire. 3. In cleaning the unit, do not use water or organic solvents. And use dry cloth. It may cause electric shock or damage to the product. 4. Do not inflow dust or wire dregs into the unit. It may cause a fire or malfunction. Précautions pour la sécurité. Après avoir lu ce guide, s'il vous plaît, placez-le dans un lieu où vous pouvez récemment le trouver. S'il vous plaît suivre les conseils suivants pour la sécurité. Avertissement L'inaccomplissement des instructions peut provoquer des blessures graves. Précaution Le produit peut être endommagé ou de provoquer des blessures si les consignes ne sont pas respectées. La signification des icones utilisées dans le produit et le manuel sont les suivants: Précaution: Blessure ou danger peuvent se produire dans des conditions particulières. Avertissement 1. Utilisez le produit seulement après avoir relié un double dispositif de sécurité pour les instruments qui ont un grand effet pour le corps humain et la propriété, comme sont les dispositifs d'énergie atomique, mets en oeuvre Médecine, de véhicules, Rails, aéronefs, Brûleurs ou produits de sécurité. L'inaccomplissement peut causer des incendies, lésions personnelles ou dommages à la propriété. L'inaccomplissement peut causer des incendies, lésions personnelles ou dommages à la propriété. 2. Ne pas réparer ou vérifier le produit tout alimenté. L'inaccomplissement peut provoquer un incendie ou des décharges électriques. 3. Utilisez le produit avec l'environnement comme il est décrit dans le manuel. Évitez le lieu d'émission de gaz corrosifs, gaz inflammables, incorporation température, haute humidité, vibrations, choc, etc. L'inaccomplissement peut provoquer un incendie ou une explosion. 4. Ne pas démonter et modifier cet appareil. S'il vous plaît nous contacter si cela est nécessaire. L'inaccomplissement pourrait causer des décharges électriques, incendies, lésions personnelles ou dommages à le produit. Précaution 1. Cette unité ne doit pas être utilisé à l'extérieur. Peut raccourcir le cycle de vie du produit ou causer un choc électrique. 2. S'il vous plaît respecter les spécifications nominales. L'inaccomplissement peut raccourcir le cycle de vie du produit et provoquer un incendie. 3. Dans nettoyer l'appareil, n'utilisez pas d'eau ou de solvants organiques. Et utiliser un chiffon sec. L'inaccomplissement peut donner lieu des décharges électriques ou des dommages au produit. 4. Ne pas laisser de poussière pénétrer l'unité. Cela pourrait provoquer un incendie ou un dysfonctionnement. <Forked> A B Forked Min. 4.1 Max. 16.0 Round Min. 4.1 Max. 16.0 Use the UL cirtified crimpt terminal. C Min. 3.0 Min. 3.0 <Round> D Max. 5.9 Max. 5.9 (unit: mm) Applicable wires AWG 22-16 (0.30 to 1.25mm2) Specifications Model ACS-20L ACS-20T ACS-40L ACS-40T ACS-50L ACS-50T Rated voltage Max. 125VDC, 125VAC 50/60Hz Rated current Max. 10A Common type Left +COM, Top +COM, Left +COM, Top +COM, Left +COM, Top +COM, Right -COM Bottom -COM Right -COM Bottom -COM Right -COM Bottom -COM Number of terminals 20EA 40EA 50EA Terminal pitch Applicable wires 7.0mm AWG22-16 (0.30 to 1.25mm2) Insulation resistance Min. 1,000 (at 500VDC megger) Dielectric strength 600VAC 50/60Hz for 1 minute Vibration Shock 0.75mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X,Y,Z directions for 2 hours 150m/s2(15G) in each of X, Y, Z directions for 3 times Environ Ambient temp. -15 to 55, Storage: -25 to 65 -ment Ambient humi. 35 to 85%RH, Storage: 35 to 85%RH Material Tightening torque CASE: MPPO, TERMINAL PIN: Brass 0.5 to 0.6 N.m Approval Weight1 Approx. 92g (Approx. 61g) Approx. 157g (Approx. 115g) Approx. 189g (Approx. 141g) 1: The weight is with packaging and the weight in parentheses is only unit weight. Environment resistance is rated at no freezing or condenstion. Wire connections ACS-20L B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 + + + ++- - - - - ACS-20T B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 + + + ++ + ++ + + A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 + + + + +- - - - - ACS-40L A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 ---- --- --- B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 + + + ++ ++ + + +- - - - - - - - - - A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 + + + ++++ + ++- - - - - - - - - - ACS-50L B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 B21 B22 B23 B24 B25 + + + ++++ + ++ - - - --- - - --- - - ++ A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 A21 A22 A23 A24 A25 + + + ++++ + ++ - - --- - - --- - - +++ ACS-40T / ACS-50T Dot line part is only for ACS-50T model. B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 B21 B22 B23 B24 B25 + + + + + + + + + ++ + + + + + + + + + + + + + + A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 A21 A22 A23 A24 A25 --- - - - -- - ---- - - - -- - - - -- - - The above specifications are subject to change without notice. Installation 1. Mounting to and Removing from DIN rail. Mounting 1) Push rail lock to the direction "". 2) Hook DIN rail connector onto DIN rail. 3) Push the unit down to the direction "" and then push up the rail lock to the unit body. Removing 1) Insert a screwdriver into hole of rail lock and pull the lock out to the direction "". 2) Removing the unit by pulling to the direction "". 2. Mounting to panel 1) This unit is able to mount on the panel with mounting holes. 2) It is recommended to use M3×30mm of spring washer screws and to use flat washers which are diameter ø6. The tightening torque should be 0.5 to 0.7N·m. Rail lock Dimensions ACS-20L(T) 80 62.5 2-ø3.5 DIN rail connector DIN rail Rail lock Panel mounting hole (Unit: mm) 10.5 41.8 39.5 11 20-M3 7 5.9 39.7 45.8 32.5 ACS-40L(T) / ACS-50L(T) A B 35.2 2-ø3.5 11 10.5 7 5.9 40-M3, 50-M3 39.5 41.8 ACS-40L(T) ACS-50L(T) A 150 184 B 89 104 C 45.8 48.9 D 39.7 34.8 D C 32.5 35.2 Caution for using 1. This unit shall not be used beyond specified temperature or humidity range. 2. Maintain voltage fluctuations in the power supply within specified range. 3. When connecting PLC or other controllers, check the polarity of power and COMMON before wiring. 4. Use AWG 16(1.25mm2) wire and applicable crimp terminals to the terminal block. 5. Turn OFF the power supply before wiring. 6. Do not use this unit at below places. Place where there is severe vibration or impact. Place where strong alkalis or acids are used. Place where there are direct ray of the sun. Place where strong magnetic field or electric noise are generated. 7. Installation environment. It shall be used indoor Altitude Max. 2,000m Pollution Degree 2 Installation Category II It may cause malfunction if above instructions are not followed. Major products Photoelectric sensors Temperature controllers Fiber optic sensors Door sensors Temperature/Humidity transducers SSR/Power controllers Door side sensors Counters Area sensors Timers Proximity sensors Panel meters Pressure sensors Tachometer/Pulse(Rate) meters Rotary encoders Display units Connector/Sockets Sensor controllers Switching mode power supplies Control switches/Lamps/Buzzers I/O Terminal Blocks & Cables Stepper motors/drivers/motion controllers Graphic/Logic panels Field network devices Laser marking system(Fiber, CO, Nd:YAG) Laser welding/soldering system http://www.autonics.com Satisfiable Partner For Factory Automation HEAD QUARTERS: 116, Ungbigongdan-gil, Yangsan-si, Gyeongsangnam-do, Korea OVERSEAS SALES: #402-404, Bucheon Techno Park, 655, Pyeongcheon-ro, Wonmi-gu, Bucheon, Gyeonggi-do, Korea TEL: 82-32-610-2730 / FAX: 82-32-329-0728 E-mail: sales@autonics.com The proposal of a product improvement and development: product@autonics.com AS-KE-01-T0002E https://manual-hub.com/