Kaadas Smart Lock Programming Instructions

KA200

Information and safety warnings

Do not load batteries until lock is completely installed.

PIN Code Information:

  1. Master PIN Code (4-10 digits): The default master PIN code is "12345678". It is required that you change it to a code of your own before programming.
  2. User PIN Code (4-10 digits): A total of 20 user codes (and one temporary one-time user code) may be programmed.
  3. Both master and user PIN codes do not support the following combination of numbers:
Combination Type Example Sequence Result
Forward number sequence 1-2-3-4-5-6-7-8-9
Backward number sequence 9-8-7-6-5-4-3-2-1
Repeat number sequence 2-2-2-2-2-2-2-2-2
Contain existing code sequence 9-1-5-6-8-3

Parts illustrations

Battery

Using only new and non-rechargeable Alkaline batteries for the best results.

Specifications: AA alkaline battery x4 (Operation voltage: 4.6~6.0V)

Remarks: Last up to seven months (10 times open/close per day)

Exterior assembly

Interior assembly

Definitions

Master code: Required for programming and feature settings. Master code can be used to unlock the door under vacation mode. The default master code needs to be changed before programming. Property owner/manager should keep this information confidential.

Auto lock: Automatically locks the deadbolt 30 seconds after unlocking. This feature is off by default. Auto Lock delay time supports 30S, 60S, 120S, and 180S settings.

Wrong entry limit: After 10 unsuccessful attempts at entering a valid PIN code, the unit will shut down for 3 minutes.

Silent mode: The beep sounds when pressing the keypad can be muted. But you will still hear low battery and system alerts.

Vacation mode: This is a security feature for you when you are leaving your home for vacation or long trip. Enabling vacation mode will restrict all user codes until the master code is entered on the keypad. If the lock is unlocked by thumb turn, the lock will sound an alarm.

One time user code: This code can only be used once and is automatically deleted when used.

How to use?

Unlock the door from outside

  1. Master code + #
  2. User code + #

Lock the door from outside

Auto re-lock mode: In auto re-lock mode, the bolt will extend out automatically in 30 seconds after unlocking.

Manual mode: Press any of the buttons on the keypad for 2 seconds.

Unlock the door from inside

Rotate the turnpiece to unlock position.

Lock the door from inside

Auto re-lock mode: In auto re-lock mode, the device will be automatically locked.

Manual mode: Rotate the turnpiece to lock position.

Z-Wave™ Module pairing instructions

(Optional network module required)

Z-Wave™ pairing setting can only be programmed through the Master Mode Menu at the Lock.

  1. Follow user guide of your Smart Hub or Network gateway to enter Learning or Pairing Mode.
  2. Touch Keypad screen with your hand to activate lock.
  3. Enter master mode.
  4. Enter "0" to enter Network Setting.
  5. Enter "1" to join network or "2" to exit network.
  6. Follow steps on your 3rd party interface or network controller to sync Z-Wave™.

CAUTION: Optional Z-Wave™ or other Network Module is required to enable this feature. If the lock is connected to a network controller, it is recommended that all programming of PIN Codes and settings is completed through a 3rd party user interface to ensure stable communication between the lock and controller is maintained.

Factory default settings

SETTINGS FACTORY DEFAULT
Master code 12345678
Auto lock Disabled
Silent mode Disabled
Wrong code entry limit 10 times
Shutdown time 3 mins
Vacation mode Disabled

Restore factory default settings

This procedure will delete all user codes which associated with the lock.

  1. Keep the door opening and unlocking.
  2. Press and hold the reset button, taking out one battery and then place it back at the same time.
  3. Keep holding the reset button for 5 seconds until you hear the sound of "BEEP".

Troubleshooting

The turnpiece can't rotate or operate the lock?

Remove and re-install the lock, making sure that the turnpiece is in vertical position.

The lock can't be locked or unlocked by keypad?

Make sure that the codes are not disabled. If needed, restore the lock's default settings.

The keypad doesn't respond when touched (no lights are visible and no beeping is heard)?

Make sure the cables are properly connected, and make sure the batteries are new installed correctly.

After the installation of batteries, there is no response when you press any button and no beeps are heard.

Check the cable connection and the polarity of the batteries. Also make sure the batteries are not dead.

Forget your master codes?

Perform a reset in order to erase all passcodes. Once the reset is complete, all passcodes will be erased and the master code will return to the default value (12345678).

FCC Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

RF Exposure Information

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

ISED Statement

English: This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions:

The digital apparatus complies with Canadian CAN ICES−3 (B)/NMB−3(B).

French: Cet appareil contient des émetteurs/récepteurs exempts de licence qui sont conformes aux RSS exemptés de licence d'Innovation, Sciences et Développement économique Canada. L'exploitation est soumise aux deux conditions suivantes :

l'appareil numérique du ciem conforme canadien peut 3 (b) / nmb 3 (b).

This device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS 102 RF exposure, users can obtain Canadian information on RF exposure and compliance.

cet appareil est conforme à l'exemption des limites d'évaluation courante dans la section 2.5 du cnr 102 et conformité avec rss 102 de l'exposition aux rf, les utilisateurs peuvent obtenir des données canadiennes sur l'exposition aux champs rf et la conformité.

This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment.

Cet équipement est conforme aux limites d'exposition aux rayonnements du Canada établies pour un environnement non contrôlé.

This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

Cet équipement doit être installé et utilisé à une distance minimale de 20 cm entre le radiateur et votre corps.

Quick set up

The default master code is 12345678. It's required that you change this to a code of your own before programming.

When setting is unsuccessful, the indicator light will flash red.

When the keypad light is off, you need to press any key to wake up the keypad in order to perform keypad operations.

Change master code

Master code + # -> Press 1 -> Wait for green light flash -> New master code + # -> Wait for green light flash -> New master code + # -> Succeed 2 green light

Add user code

Master code + # -> Press 2 -> Wait for green light flash -> New user code + # -> Wait for green light flash -> New user code + # -> Succeed 2 green light

Delete user code

Master code + # -> Press 3 -> Wait for green light flash -> Unwanted user code + # -> Wait for green light flash -> Succeed 2 green light

Silent mode

Master code + # -> Press 5 -> Wait for green light flash -> Press 2 + # -> Silent mode disabled green light flash

Master code + # -> Press 5 -> Wait for green light flash -> Press 2 + # -> Silent mode enabled green light flash

Auto lock

Master code + # -> Press 7 -> Wait for green light flash -> Press 1 + # -> Auto lock disabled green light flash

Master code + # -> Press 7 -> Wait for green light flash -> Press 2 + # -> Auto lock 30S green light flash

Master code + # -> Press 7 -> Wait for green light flash -> Press 3 + # -> Auto lock 60S green light flash

Master code + # -> Press 7 -> Wait for green light flash -> Press 4 + # -> Auto lock 120S green light flash

Master code + # -> Press 7 -> Wait for green light flash -> Press 5 + # -> Auto lock 180S green light flash

Vacation mode

Master code + # -> Press 8 -> Wait for green light flash -> Press # -> Vacation mode enabled green light flash

Add one-time code

Master code + # -> Press 9 -> Wait for green light flash -> New one-time code + # -> Wait for green light flash -> New one-time code + # -> Succeed 2 green light

Network settings

Master code + # -> Press 0 -> Wait for green light flash -> Press 1 + # -> Join network green light flash

Master code + # -> Press 0 -> Wait for green light flash -> Press 2 + # -> Exit network green light flash

Models: KA200 Smart Lock, KA200, Smart Lock, Lock
KA200ManualV1.0 Microsoft: Print To PDF

Related Documents

Preview Kaadas KA202 Advanced Information Product Manual & Z-Wave Specification
Detailed technical specification and product manual for the Kaadas KA202 Z-Wave Plus door lock, covering features, installation, software functions, and Z-Wave integration.
Preview Z-Wave Protocol Implementation Conformance Statement: Smart Key-Free Touchscreen Lock (KA210)
This document details the Z-Wave protocol implementation conformance for the Kaadas Smart Key-Free Touchscreen Lock (KA210), including general information, product features, Z-Wave product information, and technical specifications.
Preview Kaadas KA201 Smart Lock Installation and Programming Guide
Comprehensive installation and programming guide for the Kaadas KA201 Smart Lock, covering setup, features, troubleshooting, and safety information.
Preview Z-Wave Key-Free Keypad Deadbolt (KA250-Z) Conformance Statement
This document outlines the Z-Wave Protocol Implementation Conformance Statement for the Kaadas Z-Wave Key-Free Keypad Deadbolt, model KA250-Z. It details product information, features, Z-Wave compatibility, and technical specifications.
Preview Z-Wave Keypad Deadbolt KA251-Z Conformance Statement
This document provides the Z-Wave Protocol Implementation Conformance Statement for the Z-Wave Keypad Deadbolt, model KA251-Z, manufactured by Kaadas. It details product features, Z-Wave information, and technical specifications.
Preview Z-Wave Key-Free Keypad Deadbolt KA250-Z: Protocol Implementation Conformance Statement
Detailed Z-Wave Protocol Implementation Conformance Statement for the Kaadas KA250-Z Key-Free Keypad Deadbolt, including technical specifications and supported features.
Preview Kaadas K9 Smart Lock User Manual and Installation Guide
Comprehensive user manual and installation guide for the Kaadas K9 smart door lock, covering setup, features, and troubleshooting.
Preview Kaadas KS03 Smart Lock User Manual: Installation & Operation Guide
User manual for the Kaadas KS03 smart lock, covering installation, operation, quick setup, safety warnings, and definitions. Learn how to install and use your Kaadas KS03 electronic deadbolt.