Alula RE110P Indoor Motion Sensor

Pet Immune Interlogix® Compatible

Resolution Compatibles

Product Overview

The Indoor Motion Sensor alarms when motion is sensed or when the external contact is opened. It is battery powered and requires no installation tools. A Pyroflex™ sensor with HighBar™ signal processing allows for industry-leading pet immunity and catch performance.

Features

  • Industry-leading pet immunity and catch performance
  • Supports both motion zone and an external contact zone
  • Mountable on walls or in corners
  • 5 year warranty

Enrollment

Enroll by placing the panel into learn mode and then tripping the tamper switch. Enroll the external contact zone by inserting the battery with the external contact closed.

Suggested Group Types

  • Use Interior Follower for the motion zone
  • Use Perimeter for the external contact zone

Installation

Install using the included 3M™ VHB™ tape to adhere the motion sensor on a wall or in a corner. The tape should be applied to the back when wall mounting or to the back bevels when corner mounting. Alternatively, screw mounting can be done by punching out the screw mounting holes.

Diagram showing screw mounting holes on the back of the sensor.Diagram illustrating vertical orientation, with 'Ceiling' at the top and 'Floor' at the bottom.

Installation Tips

  • Mount 7.5 to 9.5 feet from the floor for an optimal balance between catch performance and pet immunity.
  • Remove the cover and circuit board before trying to punch out the screw mounting holes.
  • Ensure the bug foam stays intact and snug around the IR sensing element when re-installing the circuit board.

External Contact

  • Use a normally-closed contact because the motion sensor will transmit an alarm when it sees the external contact open.
  • Do not use end-of-line resistors.

Pro Tips

Walk Test Mode

Walk test mode is entered by pressing the motion sensor's tamper button. The walk test lasts three minutes.

Walk Test Operation

  • The walk test LED turns on when motion is sensed.
  • The motion sensor performs a re-calibration after each activation. The re-calibration takes about 30 seconds. The sensor will NOT sense motion during the re-calibration.
  • Wireless transmissions are sent for each detection, so walk test mode can also be used to test the panel.

3M™ VHB™ tape works great if the surface is properly prepared and firm pressure is applied for over 10 seconds.

Surface Preparation

  • Clean the surface
  • Ensure the mounting surface temperature is above 50 °F
Diagram of the sensor's internal components, showing the Walk Test LED, Cover Tamper Switch, Bug Foam, IR Sensing Element, sensitivity jumper (labeled 'Low - Jumper ON Sensitivity' and 'High - Jumper OFF'), Battery terminals ([+] and [-]), and External Contact terminals.

Motion Lockout

Motion lockout is active for three minutes after a motion event is detected. Motion events will be ignored during the motion lockout period.

Motion Sensitivity

Motion sensitivity can be adjusted by the sensitivity jumper on the circuit board.

  • Jumper Installed (lower sensitivity): Detects person in 3 to 5 steps. Increases pet immunity, usually for security applications.
  • Jumper NOT Installed (higher sensitivity): Detects person in 2 to 4 steps. Usually for occupancy applications.

Pet Immunity

Pet immunity is optimized when the motion sensor is mounted at 7.5 to 9.5 feet high and aimed away from house features that could allow pets to be high in the detection field (e.g. stairs, counter tops, tall furniture).

Graph illustrating pet immunity. The detection field is shown from 0 to 40 feet horizontally. A lower zone (0 to 3.2 feet) is marked as 'pet immune'. The upper zone (3.2 to 7.5 feet) is also shown, with a warning symbol ⚠️ indicating potential pet detection at higher levels, especially near furniture or stairs.

Motion Catch Performance

Motion catch performance is best when the motion sensor is positioned so a person would typically walk across the front of the motion sensor instead of directly toward the motion sensor.

Motion Detection Tips

  • Provide a clear line-of-sight to the monitored area and remember that glass blocks infrared energy.
  • Aim away from windows and sunlight.
  • Aim away from air conditioners, heaters or heating/cooling vents.

Accessories

Gimbal mount (RE019 and RE019-10) allows the motion sensor direction to be adjusted after mounting on a wall. Horizontal beam lens (RE020) has less look-down which results in increased pet immunity.

Specifications

Field of View

Diagram showing the side detection field of view from a mounting height of 7.5 feet. The field extends horizontally from 0 to 40 feet, with coverage narrowing at greater distances.Diagram showing the side detection field of view from a mounting height of 9.5 feet. The field extends horizontally from 0 to 40 feet, with coverage narrowing at greater distances.Diagram showing the top detection field of view, extending horizontally from 0 to 40 feet in both directions from the sensor's front, creating a wide fan shape.

Physical

  • Housing Dimensions: 3.50 x 2.40 x 1.70 inches (8.9 x 6.1 x 4.3 cm)
  • Weight with Battery: 3.2 ounces (91 grams)
  • Mounting Fastener: 3M™ VHB™ Tape or Screws (both provided)

Environmental

  • Operating Temperature: 32 to 120 °F (0 to 49 °C)
  • Maximum Humidity: 85% non-condensing relative humidity

Sensor Specifications

  • Frequency: 319.5 MHz
  • Pet Immunity: Two 60-pound dogs or one 85-pound dog
  • Replacement Battery: One Panasonic® CR123A
  • Nominal Battery Life: 6 to 8 years
  • Battery Voltage: 3.0 VDC (Nominal), 2.2 VDC (Low)
  • Current Draw: 30 mA (Maximum), 20 uA (Quiescent)
  • Optimal Mounting Height: 7.5 to 9.5 feet (2.3 to 3.0 m)
  • Transmitted Indications: Cover Tamper, Low Battery, Supervision
  • Maximum Wire Length on External Contact: 7.5 feet

Certification

RE110P: FCC, IC

Specifications subject to change without notice.

Warranty

Alula will replace products that are defective in their first five (5) years.

Notices

IC Notice

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux cnr d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) L'appareil ne doit pas produire de brouillage, et (2) L'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

IC: 8310A-RE110P

FCC Notice

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference that may be received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by Alula could void the user's authority to operate this equipment.

FCC ID: U5X-RE110P

Trademarks

Alula is a trademark owned by Alula Holdings, LLC. "Interlogix" is a trademark owned by United Technologies Electronic Controls Inc. Alula products will function with Interlogix systems. However, no Alula product is produced by, endorsed by, or is officially associated with Interlogix. Alula recommends verifying proper enrollment and operation, per control panel installation instructions, at installation.

3M and VHB are trademarks owned by 3M Company. Panasonic is a trademark owned by Panasonic Corporation. Pyroflex and Highbar are trademarks of Suren.

Document Revision: 47-0005-01 • RevD • 2019-02-19

Tech Support Line: (888) 88-ALULA • (888)-882-5852

Website: alula.net