1. Wiring Instructions

Wire Color Definition:

  • Red: +12V Positive
  • Black: GND Negative
  • Blue: CASE (Anti-tamper output)
  • White: D0 (Wiegand output)
  • Green: D1 (Wiegand output)
  • Yellow: R-B (RS-485 output)
  • Purple: R-A (RS-485 output)
  • Brown: LED

Length Specification of the wires: AWG26# Black tinned copper shielded wire

Note:

  • It will damage the product when the black (GND) is connected to the positive terminal and the DO or D1 is connected to the negative.
  • Do not wire with power on.

RS-485 Wiring Note: Use shielded twisted pair for RS-485 wiring when transmission is over 100m. The power cable must be connected separately from the signal cable.

Controller Upgrade Note: The controller supports two upgrades simultaneously. If the upgrade is not completed within 30 minutes, wait for the controller to start automatically to indicate completion.

2. Packing and Accessories

  • 1 x Reader
  • 2 x φ3 screws
  • 2 x rubbers
  • 1 x User manual with install instruction

3. Specifications

Parameter Specification
Card Type IC (Mifare cards)
Power supply DC12V±20%
Static current 5 MA~12MA
Working current 5 MA~22MA
Operating Temperature -40°C~60°C
Operating Humidity 0%~95% (non-condensing)
Transmit Frequency 13.56MHz
Read Range 20mm~65mm
Output Format RS-485(OSDP) or Wiegand 26~37
RS-485 Transmission Distance 100M
WG Transmission Distance 100M
IP Rating IP67
Dimension L95*W50*H20(mm)
Weight 136g

4. Functions Instruction

  1. When swiping the card, the buzzer sounds for 200MS, and outputs Wiegand signal and RS485 signal simultaneously.
  2. When RS485 confirms an authorized card: red light off, green light on, then red light on, green light off after 200MS.
  3. When RS485 confirms an illegal card: buzzer gives 3 short beeps consecutively, green light remains off.
  4. When the LED line is pulled low, the LED turns green and the buzzer sounds. When the LED line is pulled high, the LED turns red and the buzzer stops.
  5. If the reader does not trigger the tamper, the CASE line outputs a low level. If the reader triggers the tamper, the CASE line outputs a high level. Triggering timeout is 15 seconds; the buzzer returns to normal.
  6. Unlock via card swiping and Bluetooth.
  7. Communicates through the RS-485 port, Wiegand port, and Bluetooth.
  8. Prompts using the buzzer and indicator light.

5. About Wiegand

  1. Factory default is Wiegand34. Any formats between Wiegand26 and 37 are customizable.
  2. Green wire is Wiegand DO and White wire is Wiegand D1. Normally it is high level; low level indicates data output. Pulse width is 40μs; interval is 2ms.

6. Anti-tamper Alarm

When the anti-tamper alarm function is enabled, the buzzer will emit a continuous alarm if the card reader is illegally dismantled. The alarm timeout is 15 seconds.

Can be used with APP & Controller together.

7. FCC Regulations

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

8. FCC Caution

Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.

9. Radiation Exposure Statement

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.

10. Installation

  1. Drill holes according to the backplate.
  2. Mount the backplate to the wall.
  3. Mount the reader to the backplate.
  4. Secure the reader to the backplate with the screw on the bottom as shown.

Diagram showing installation steps:

[Diagram: Shows a backplate being mounted to a wall, then the reader being attached to the backplate and secured with a screw at the bottom.]

Models: ASR2100Z-B Access Reader, ASR2100Z-B, Access Reader, Reader

Original Document

If the viewer doesn’t load, open the PDF directly.