User Guide for Milesight models including: 2AYHY-WS201, 2AYHYWS201, ws201, Smart Fill Level Monitoring Sensor, WS201 Smart Fill Level Monitoring Sensor, Fill Level Monitoring Sensor, Monitoring Sensor, Sensor
Xiamen Milesight IoT Co., Ltd. WS201 2AYHY-WS201 2AYHYWS201 ws201
Xiamen Milesight IoT Co., Ltd. WS201 Smart Fill Level Monitoring Sensor 2AYHY-WS201 2AYHYWS201 ws201
File Info : application/pdf, 2 Pages, 3.29MB
DocumentDocument1.Packing List Smart Fill Level Monitoring Sensor WS201 1 × WS201 Sensor 1 × CR2450 Battery 1 × 3M Tape SMART FILL LEVEL MONITORING SENSOR FEATURING LoRaWAN ® 1 × Mirror Cleaning Cloth 1 × Quick Start Guide 2.Hardware Introduction NFC Area Reset Button ToF Sensor LED Indicator Battery 3.Reset Button Patterns WS201 sensor equips with reset button inside the device for emergency reset or reboot. Usually users can use NFC to complete all steps. Function Reboot Reset to Factory Default Check On/ Off Status Action Press and hold the reset button for more than 3 seconds. Press and hold the reset button for more than 10 seconds. Quickly press the reset button. LED Indicator Blinks slowly Blinks quickly Light On Device is On. Light Off Device is Off. 4.Power Supply 1.Remove the device back cover. 2.Insert the battery into the battery slot with the positive facing up. After inserting,the device will power on automatically. 3.Align the holes on the rear cover with the WS201, reinstall the cover to the device. 5.Configuration Guide 1. Download "Milesight ToolBox" App on an NFC- supported smartphone. Android iOS 2. Open "Milesight ToolBox" App and attach the smartphone with NFC area to read/write the device until App shows a successful prompt. (Default config password: 123456) NFC Besides, it can be configured by dedicated NFC reader provided by Milesight IoT. Quick Start Guide Cloud App All software & files can be downloaded from https://www.milesight-iot.com/documents-download/ Milesight IoT Co., Ltd. www.milesight-iot.com Add: Building C0 9 , Sof t w are Park Phase III, Xiamen 3 6 10 2 4 , Fujian, China 6.Installation Paste 3M tape to the back of WS201, then tear the other side and place it on a flat surface. Installation Note: In order to provide the best data transmission, please ensure the device is within the signal range of the LoRaWAN® gateway and keep it away from metal objects and obstacles. Avoid strong light, like direct sunlight or IR LED, in the detection area. Do not install the device close to glass or mirror. After installation, please remove the protective film. Do not touch the lens of sensor directly to avoid leaving the fingerprint on it. The detecting performance will be affected if there's dust on the lens. Please use the mirror cleaning cloth to clean the lens if needed. The device must be placed in a horizontal position on the top of the object so that it has a clear path to the object. Prevent device from water. 7. FCC Statement Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and. (2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator& your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 8. Warranty Limited Warranty Protection 1/2/3 years from original purchase date against all manufacturing defects. This Warranty does not cover: Loss or damage to the equipment due to improper maintenance, or failure to follow operating instructions. If defects or damages are caused by the use of unauthorized parts or by service by other than our authorized agent. Product Warranty Period Overview Milesight IoT Products Warranty Period 5G Series/Industrial Routers/IoT Gateways 3 Years IoT Sensors/IoT Controllers/Sensing Products 2 Years IoT Weather Station 1 Year Gas detecting probes will come with a 1-year warranty For detailed information, visit our website at http://www.milesight.com or http://www.milesight-iot.com Email: iot.support@milesight.com Tel: 86-592-5085280 Dealer Stamp: Model: Date of Purchase: QC: Serial Number: