Owner's Manual for BreathSafe models including: 963K Variable Speed Pressuriser Loader, 963K, Variable Speed Pressuriser Loader, Speed Pressuriser Loader, Pressuriser Loader
File Info : application/pdf, 29 Pages, 2.63MB
DocumentDocumentKit Part Number: 700069 +61 7 3276 7833 www.breathe-safe.com.au sales@breathe-safe.com 62 Mica Street, Carole Park, 4300, QLD Parts and Service Manual CATERPILLAR 963K / 973D LOADER HEPA H14 Variable Speed Pressuriser | INPRESS TS Cabin Display with CO2 Sensor | HEPA Return Air Filter Controlled Document: M0184 Issue Date: 10/10/23 Revision: 1 CATERPILLAR 963K / 973D Loader CONTENTS Installation .................................... 1 Safety ........................................... 2 Critical Parts & Maintenance Schedule ....................................... 3 Operator Guide ............................. 4 Specifications - Pressuriser ............ 5 Parts List .................................. 6-12 Technical Details .................... 13-14 Smoke Emitter Cabin Pressure Leak Test............................................. 15 Cabin Sealing Test Pressure ......... 16 Commissioning Procedures.......... 17 Troubleshooting Guide ................ 18 User Settings Instructions ....... 19-24 Data Download ...................... 25-27 Warranty .................................... 28 Manufacturer Type Model Cabin Pressure Max Set Auto Cabin Pressure INSTALLATION OVERVIEW CATERPILLAR Loader 963K 973D INSTALLATION HEPA H14 Variable Speed Pressuriser INPRESS TS Cabin Display with Data Recorder HEPA Return Air Filter 1 CATERPILLAR 963K / 973D Loader WARNING THE PRESSURISATION SYSTEM DESCRIBED IN THIS MANUAL HAS THE FOLLOWING AREAS WHICH MAY BE DANGEROUS IF NOT TREATED WITH GREAT CARE. QUALIFIED STAFF MUST WEAR THE CORRECT PERSONAL PROTECTIVE EQUIPMENT WHEN CLEANING AND SERVICING THIS UNIT DUE TO DUST AND FIBRES WHICH MAY BE CAUGHT BY THE STAGES OF AIR FILTRATION DURING NORMAL UNIT OPERATION. THE ELECTRICAL POWER SYSTEM IS SUPPLIED BY 12V DC OR 24V DC AND NO WORK SHOULD BE CARRIED OUT ON THE PRESSURISER SYSTEM WITHOUT THE CORRECT SAFE WORK PROCEDURES AND ELECTRICAL SAFETY MEASURES BEING TAKEN, AND ALL RELEVANT CIRCUIT BREAKER OPENED TO ISOLATE THE CIRCUIT. THE AIR FILTRATION SYSTEM MAY HAVE SEVERAL TYPES OF HIGH-SPEED ROTATING EQUIPMENT INSTALLED WITH VERY SHARP EDGES. ENSURE ALL SAFETY GUARD ARE IN PLACE WHILE THE SYSTEM IS RUNNING. Please be aware that HEPA filters cannot be cleaned and must be replaced at the end of their lifecycle or if filter media has been damaged. SAFETY Particulate Behaviour This is the length of time it takes for a particle to drop from a height of 1.5m in STILL air. Warehouses and workshops do not have still air, so hazardous airborne particulates may remain in air for longer, increasing chance for workers to breathe in dust. Ensure PPE is worn when installing this system. Hard Hat Eye Protection Dust Mask Ear Protection Protective Clothing 2 CATERPILLAR 963K / 973D Loader Maintenance Schedule The following tables show our suggested maintenance schedule for all units. Please note that site conditions may alter this. Excludes high corrosion environments. Data download is required to claim the 3-year warranty on Brushless Blower Motor. Inspect every 500 Hours and replace when filter is full* Component / System Action Required Turbo Pre-cleaner Pressuriser Blower Check operation of the Turbo PreCleaner. Ensure blower is operational. HEPA Primary Filter p/n: 500000 HEPA Return Air Filter P/N: 500016 Inspect filter capacity indicator. Replace HEPA filter when 80% or greater. Vacuum out housing before replacing the filter elements. Vacuum inside cabin floor before replacing filter. Filter Frame Assembly, Mounts, Seals and Filter Housing Check door seals, all bolts, screws, and all mounts are secure. Check the filter canister & ensure it is correctly fitted. Check latches are operational and in good order. Replace / Re-tension fixtures and fittings required. 15,000 Hours / 36 months* Component / System Action Required 500 Hour Inspection All 500-hour inspection actions. Pressuriser's Blower 200002 Replace BRUSHLESS Pressuriser blower. CRITICAL PARTS & MAINTENANCE SCHEDULE Item Part Number 1 500000 2 500016 3 200002 4 200027 Critical Parts Qty. Description 1 Fresh Air HEPA H14 Filter (Tested as per EN1822) 1 HEPA Return Air Filter 1 Brushless Blower Motor 24V 1 BreatheSafe Digital Display Data Recorder (INPRESS TS) Service Interval 1000* Hours (>80% fan capacity) 500* Hours 15,000 Hours *Filter service hours are subject to cab sealing efficiency, site conditions and correct system use. Suggested Schedule Servicing* Fan Capacity Indicator The filter is serviceable if the motor capacity is between 10% & 80%. We recommend that the filter is changed if the capacity is over 80%. *Site dependent 3 CATERPILLAR 963K / 973D Loader OPERATORS CHECKLIST PRE-START 1. Visually inspect the BreatheSafe system for any damage. 2. Visually inspect the cabin for any damage to doors, windows, seals. 3. Please remove dust & debris from shoes and clothes before entering the cabin. 4. Ensure door(s) and windows are closed correctly. 5. Start engine and turn HVAC on to speed 2 (medium speed). 6. After fixed speed delay, the BreatheSafe display will show 50 Pascals or pre-set value. The system is working correctly when the pascal value is green. >> There is no further action required << NORMAL OPERATING CONDITION Cab Air Conditioning BreatheSafe recommends OEM air conditioning fan is set at mid speed or greater to circulate air around the breathing zone and minimise CO. Acceptable operating range for BreatheSafe fan 10-80%. >80% recommend maintenance. ALERTS Fixed Fan Start Delay · Allows the operator to carry out pre-start checks limiting at 30% fan speed, press the red text to disable. CO Level Alert (if equipped) · Ensure air conditioning fan is set at mid speed or greater to circulate air and minimise CO. Low Pressure Alarm · Cabin is not maintaining positive pressure check doors and windows are closed correctly. · Refer to maintenance department to check filters and cabin sealing. Ensure filters are serviceable. Check Filter · Reminder to inspect or replace filter. Service hour meter requires re-set. · Refer to maintenance department. OPERATOR GUIDE 4 CATERPILLAR 963K / 973D Loader Specifications High-Capacity HEPA Pressuriser Blower : Brushless Blower P/N 200002. Protection : Locked Rotor Protection (Sub Zero Environments) Under Voltage, Under/Over Current & Over Temperature. Voltage : 24VDC. Current Draw Air Flow : 11 amps (peak). *Note: Motor has slow start to stop excessive in-rush current. : Up to 30-300 m3/h or 50-215 CFM. Pre-cleaner : Integrated VLR (Very Low Restriction). Turbo Pre-Cleaner. Filter Element Plugs & Fittings : BreatheSafe HEPA Primary Filter (H14=99.99% MPPS) TESTED AS PER EN1822 P/N 500000. : Mining Spec. Deutsch electrical plugs as standard. Construction : High strength composite construction. Serviceability : Easy access HEPA filter with twist-lock (TL) dust cap single assembly. Mounting : Heavy Duty adjustable mounting brackets. Design : Fully designed in SolidWorks 3D CAD & Ansys Engineering Simulation Software. FEA Testing : Critical components FEA (Finite Element Analyst) tested in Solid Works Simulation. CFD Testing : CFD (Computational Fluid Dynamics) simulations in Flow Works to ensure optimum air flow through the system. SPECIFICATIONS HIGH-CAPACITY HEPA PRESSURISER DH DHPR DHAC DHACPR CPM CPU DB DPM GAS HEPA HPAFU HRAF HVAC MAF OEM PM RH TEMP TS UI VMS VS OGSP CO2s List of Abbreviations Dual HEPA Dual HEPA Powered Recirculation Dual HEPA Activated Carbon Dual HEPA Activated Carbon Powered Recirculation Cabin Pressure Monitor Central Processing Unit Decibel Sensor Diesel Particulate Matter Gas Sensor High-Efficiency Particulate Air Filter High Pressure Air Filtration Unit HEPA Return Air Filter Heating Ventilation and Air Conditioning Mass Air Flow Original Equipment Manufacturer Particulate Mass Relative Humidity Temperature Touch screen User Interface Vehicle Monitoring System Vibration Sensor OnGuard Sensor Pod CO2 Sensor INPRESS TS 5 CATERPILLAR 963K / 973D Loader Item No. Qty. 1 1 2 4 3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11 1 12 3 13 3 14 4 15 8 16 4 17 5 Description Pre-cleaner Hood & Rotor Assy Pre-cleaner Injector Ring TL Fan Blade (inc. in #7) TL Nose Cone / Pre-cleaner TL Motor Housing TL Filter Housing 24v DC Brushless VSD Motor & TL Fan Blade O Ring Seal Kit 2 Parts Included in 8 Wiring Sleeve HEPA H14 Filter M6 Nyloc Nut M6 x 55mm Hex Bolt M8 x 190 Hex Bolt M8 x 22mm O/D HD Washer M8 Nyloc Nut M4 x 75mm Pan Head Phillips Screw Part No. 200004 200005 200006 200007 200008 200009 200002 200010 200011 200012 500000 300218 (M6NYL) 300982 (M655B) 301136 (M8190B) 300230 (M8222HTW) 300249 (M8NYL) 300162 (M475PBH) 4 2 1 PARTS LIST TL4 24V DC PRESSURISER UNIT PRESSURISER ASSEMBLY No: 200000 12 5 13 7 11 6 9 16 15 8 14 10 17 6 CATERPILLAR 963K / 973D Loader Item No. 1 2 3 4 5 6 Part No. 100056A01 100071F01 100056P01 100071M01 100071R01 100071-Q920 Rev Description 2 TL Assembly 0 Fresh Air Module 0 Pipework Module 0 Monitor Mount Module 0 R.A.F. Assembly 1 Cover Qty Colour 1 Satin Black MX88-124 1 Satin Black MX88-124 1 Satin Black MX88-124 1 Satin Black MX88-124 1 Satin Black MX88-124 1 Satin Black MX88-124 Kit Part Number: 700069 Category Module Module Module Module Module Part PARTS LIST GA COMPLETE ASSEMBLY No: 700069 7 CATERPILLAR 963K / 973D Loader Item No. 1 2 3 4 5 6 7 Part No. Rev Description 100056A02 2 TL Mount Plate Weldment 100071A03 0 S02 Cannister Mount T Angle RH Assy 100071A04 0 S02 Cannister Mount T Angle LH Assy KDTQ218-551735 0 Spacer Ø35 x Ø17 x 55L ST100008 [*] TL Mount Brkt H ST100044 [*] TL Rain Cover / Guard 200000 [*] TL4 24V DC Unit Qty Material 1 1 1 2 Mild Steel 1 Mild Steel 1 1 - Thickness Ø35 O/D 3 - Category Weld Assy Weld Assy Weld Assy Stock Item Stock Item Stock Item Stock Item PARTS LIST PRESSURISER MODULE 8 CATERPILLAR 963K / 973D Loader Item No. 1 2 3 4 5 6 7 8 9 10 11 Part No. 100071-F850 100071-F851 100071-F852 100071-F853 100071-F854 100071-F855 100071-F856 100071-F857 100071-F858 100071-F859 100071-F860 Rev Description 1 Duct Main Body (Inner) 2 Duct Main Body (Outer) 0 Duct Top Cover 1 Duct Bottom Cover 0 Spigot 1 Internal Spacer 1 Bottom Angle 1 Internal Stiffener Angle 1 Side Angle Mount 0 Duct Infill Large 0 Duct Infill Small Qty Material 1 Zan 1 Zan 1 Zan 1 Zan 1 Mild Steel Tube 3 Zan 1 Zan 1 Zan 1 Zan 1 Zan 1 Zan Thickness 1.55 1.55 1.55 1.55 Ø76 O/D x 1.6 WT 1.55 1.55 1.55 1.55 1.55 1.55 Category Part Part Part Part Part Part Part Part Part Part Part PARTS LIST FRESH AIR MODULE 9 CATERPILLAR 963K / 973D Loader Item No. 1 2 3 4 5 6 7 8 9 Part No. 100071P02 300388-0060 300388-0080 76ODSS250 3" 90 Deg 3" 90 Deg 200308 300851 TQ553376A1 Rev Description Qty Material 0 3" Pipe Assembly 1 (Prt Dwgs) - 76.3 x 1.6 @60mm 1 Stainless Steel - 76.3 x 1.6 @80mm 1 Stainless Steel - 76.3 x 1.6 @250mm 1 Stainless Steel - 3" x 90* Elbow Long Drop Sil 2 Silicone - 3" x 90* Elbow Long Drop Sil 1 Silicone - 3" 90Deg Short Elbow 1 Silicone - 3" Hose 1 Silicone 0 3" Stauff Clamp Assy 1 (Prt Dwgs) Thickness (Prt Dwgs) Ø3.0"ODx1.6W/T Ø3.0"ODx1.6W/T Ø3.0"ODx1.6W/T (Prt Dwgs) Category Pipework Pipework Pipework Pipework Pipework Pipework Pipework Pipework Pipework PARTS LIST PIPEWORK MODULE 10 CATERPILLAR 963K / 973D Loader Item No. 1 2 Part No. 100071-M680_0 250101 Rev Description Qty Material Thickness Colour Category 0 Display Mount Bracket 1 Mild Steel 3 Satin Black MX88-124 Part [*] Controller Lrg Std Box 1 Zan (Prt Dwgs) (Per Assy) Stock Item PARTS LIST MONITOR MODULE 11 CATERPILLAR 963K / 973D Loader Item No. 1 2 3 Part No. 100071-R142 100071R02_0 500016 Rev Description 0 Filter Frame 0 Filter Base [*] HEPA Filter 285x165x31 Qty Material 1 Zan 1 (Per Dwgs) 1 - Thickness 1.6mm (Per Dwgs) - Category R.A.F. Frame Weld Assy - PARTS LIST RETURN AIR MODULE 12 CATERPILLAR 963K / 973D Loader Display Key Features · Digital cabin pressure monitoring system · Automatic cabin pressure control · Intelligent fan speed output · Data logger · Alarm for low-pressure (RS20) · Light sensor for automatic dimming of the screen CO2 Sensor TECHNICAL DETAILS · CO2 Sensor Type is NDIR (Non-Dispersive Infrared) · Sample Rate is every 2 seconds · 12-30V DC Operating Voltage · Automatic Altitude Compensation · Alarm Set points are adjustable · No setup required 13 CATERPILLAR 963K / 973D Loader Connections: 200027 Item 1 2 3 4 Destination PIPE A AMBIENT PRESSURE OUTSIDE PIPE B POSITIVE PRESSURE INSIDE RJ45 CONNECTOR CO2 SENSOR OVERRIDE TOGGLE SW = MAX SPEED Item 1 2 3 4 5 6 7 8 9 10 11 12 Destination 12/24 VOLT POSITIVE SUPPLY CAN H OPTION CAN L OPTION SERIAL TRANSMIT RS232 MOTOR CONTROL VOLTS OUT ALARM + OUTPUT TEMP SENSOR NO CONNECTION SERIAL RECEIVE RS232 DOOR INPUT (+) WINDOW INPUT (+) 0V NEGATIVE GROUND Wiring Diagram TECHNICAL DETAILS v v 14 CATERPILLAR 963K / 973D Loader * Do not handle until MSDS & all safety precautions have been read and understood. Use personal protective equipment as required. Before use, carefully read the product label. Safe work practices are advised to avoid eye or skin contact and inhalation. Observe good personal hygiene, including washing hands before eating. Prohibit eating, drinking, and smoking in contaminated areas. Avoid inhalation. Mechanical extraction ventilation is recommended when the removal of atmospheric contaminants is required. Maintain dust / fume levels below the recommended exposure standard. For small amounts, absorb with sand, vermiculite or similar and dispose of at an approved landfill site. SMOKE EMITTER CABIN PRESSURE LEAK TEST Link to MSDS: SMOKE GENERATOR TQ7621AT30S.pdf WARNING For Professional Use Only keep out of reach of children. Do not ignite near or around flammable materials. Use only in well-ventilated areas, outdoors, and/or with proper respiratory protection. Persons with respiratory sensitivity should avoid exposure to any smoke. Concentrated smoke may cause severe burns to the skin, eyes, or respiratory system. Improper use may result in sufficient inhalation of smoke to cause respiratory tract irritation and lung damage. Harmful if swallowed. Personal Protective Equipment (PPE) Safety glasses must be worn at all times. Sturdy footwear with rubber soles must be worn. Respiratory protection devices may be required. Gloves may be worn. DANGER Use only as directed. Do not handle until all safety precautions, including Safety Data Sheet, have been read and understood. The product contains hexachloroethane. Wear protective clothing. If exposed or concerned, get medical advice. Store in a cool, dry, secure location. KEEP OUT OF REACH OF CHILDREN. Dispose of contents/container per location regulations. When used as directed, exposure should be limited and usually poses no hazard because the hexachloroethane is consumed inside the tube as smoke is produced. Directions: (Smoke Bomb) 1. Ensure other workers in close proximity are informed of use. Place on a non-combustible container, away from flammable materials. 2. Place at Blower intake, or upwind of target area, or near centre of space. 3. Orient "Smoke Issues Here" toward air stream, away from surfaces. Place candle on a flame / heat resistance plate if not it will melt into the plastic surface. 4. Ensure smoke will not create any hazard where it is anticipated to go. 5. Ignite emitter inside the cabin using site approved device i.e., solder torch or `lighter' and conduct smoke test. 6. Do not touch or hold smoke generator after ignition item becomes very hot & remains hot after use. Pre-operational Safety Checks Locate and ensure you are familiar with all machine operations and controls. Check work area and walkways to ensure no slip/trip hazards are present. Ensure the work area is clean and clear of any flammable material & fire extinguish device is present. Operational Safety Checks Ensure the machine is correctly isolated / immobilized. Ensure other persons do not inhale smoke haze. Take care and do not place a lit emitter close to a flammable surface. Ending Operations and Cleaning Up Leave the work area in a safe, clean, and tidy state. Smoke Emitter Cabin Pressure Leak Test 1. The pressuriser system is switched on (TEST MODE). 2. Hold the smoke emitter angled down. 3. Ignite emitter using site approved ignitor i.e., solder torch or `lighter'. 4. When the product ignites, remove the lighter. 5. If the product flames up, blow out the flame. 6. Place the emitter in a non-flammable container and place it inside the cabin at floor level and close the door/windows. 7. Observe smoke leaks to indicate worn-out or broken seal locations. Check leakage points outside the cabin. 8. Do not come into contact with or inhale smoke haze. 9. Wait until the smoke haze completely disperses before re-entering the cabin. Open door to allow sufficient ventilation of smoke prior to entering cabin. Falls Fumes Fire Potential Hazards May cause cancer Exposure is highly unlikely when the product is used as directed. Direct contact with the product does not occur. Don't Do not use if an open flame is forbidden. Never leave the emitter [cabin test] unattended. *This SWP does not necessarily cover all possible hazards associated with this equipment and should be used in conjunction with other references. It is designed as a guide to be used to compliment training and as a reminder to users prior to equipment use. 15 CATERPILLAR 963K / 973D Loader CABIN SEALING TEST PROCEDURE 1 Start Engine Pressuriser System is ON Cabin Sealing Efficiency Test Procedure 2 Ensure all windows & door(s) are CLOSED correctly (no cabin pressure leaks) NOTE: for a new cabin with effective seals, you may need to open a window slightly before closing the door to bleed the static cabin air pressure outwards. Once door is fully closed then close windows to begin testing. 3 Enter the Settings menu via the touch screen button. 4 Select and press the System Check button to go to System Test Max Fan. 5 Record / photograph the maximum cabin pressure achieved. 12:18 12/04/2022 25% Cabin Pressure 50 Pa CO2 Concentration 561 ppm BACK Settings SYSTEM CHECK SET MAX VIEW GRAPH EVENT LOG SITE ACCESS MENU Press Settings. Press "System Check Set Max" box. 12:18 12/04/2022 100% System Test Max Fan Cabin Pressure 425 Pascals Record / Photograph the cabin pressure result (Max Fan Speed). 16 CATERPILLAR 963K / 973D Loader Commissioning Procedures COMMISSIONING PROCEDURES CABIN PRESSURISER Follow each step of the installation guide that was supplied with the BreatheSafe kit. Cabin sealing is an integral part of RS20 & ISO 23875; you must ensure that cabin seals are adequate for maintaining positive pressure. In addition, the site (end- user) must have the correct procedure(s) for servicing OPERATOR enclosure seals in a proactive manner rather than reactive. Items such as door and window seals must be in good working order or new seals FITTED before the BreatheSafe system installation. Touch-screen cabin pressure display/controller Part# 200027: *System Check Function: enter the Settings menu option and select "System Check Set Max." The minimum BreatheSafe requirement for cabin sealing efficiency is 250 pascals; if this result is not met, it is essential to re-examine and find pressure leaks of the enclosure and apply new sealing measures. Submission for commissioning procedure as per the diagram below: "System Check" Proceed to online commissioning: Commissioning - BreatheSafe (breathe-safe.com.au) The commissioning images required are: · ID plate / Machine Serial Number / Asset Number or Call Sign · INPRESS TL Pressuriser location · HEPA Return Air Filter Location Option: Powered Return Air Filter · Cabin Pressure Display Location Including the "System Check" maximum cabin pressure result with motor output capacity % Fill in the BreatheSafe Service Tag with the following details: · Machine Serial Number and Installers details · Date installed and System Check result (max cabin pressure) · The set cabin pressure with actual pressure and motor percentage output · Verify the 250-pascal threshold was achieved = pass OR not achieved = fail** Please upload machine and installation details in conjunction with the required images. A Commissioning Certificate will be sent to the email address you nominate. **Extended warranty for (RS20 & ISO 23875) BreatheSafe Systems is only applicable to operator enclosures meeting this requirement. 17 CATERPILLAR 963K / 973D Loader BREATHESAFE SYSTEM TROUBLE SHOOTING GUIDE *TOUCH CONTROL FAULT POSSIBLE CAUSE SOLUTION *ERR error code Poor sensor connection Remove & refit pod connection cable Corrupted coding Access factory setup - default reset - pin 6759 *Check filter alarm Service hour timeout Access Check Runtime menu - reset hours via 7597 code Temperature / CO2 error Sensor not connected Fit sensor or disable via site access CO2 & or temperature menu Pressuriser running at full speed/noisy Filter blocked Service filter Door or window open Ensure doors & windows securely shut Cabin sealing capacity not adequate Perform pressure test procedure & seal leak points as required Sense pipe blocked Ensure clear & not bent Internal sensor damaged Replace controller **No need to change setpoint Filter blocking quickly Defective cabin sealing Perform pressure test procedure & seal leak points as required Pre-cleaner failed Check operation & replace if necessary Display blank Poor power supply Check mains supply fuse & correct voltage Check voltage & 20AMP supply/connections at pin 1 @ monitor Check earth continuity at controller pin 12 Failed controller Replace monitor Controller showing 0.0 pressure Fresh air filter blocked Check filter condition & replace if required. Low pressure alarm Door or window open Ensure doors & windows securely shut Cabin sealing capacity not adequate Perform pressure test procedure & rectify cab sealing Pressuriser not operating Ensure correct voltage 12v or 24v to pressuriser motor pin A Check 1.6V - 10V present at motor Pin C Check 20A Supply fuse Check earth continuity Pin B Pressure sense tube blocked Unplug at monitor & ensure clear flow to external of cabin Ensure pressure tube fitted correct port A **No need to change setpoint Pressuriser not working Poor power supply Check 20A mains fuse & correct voltage Ensure adequate wire size & no voltage drop Ensure correct voltage 12v or 24v to pressuriser motor pin A Check 1.6V - 10V present at motor Pin C Poor earth Check earth continuity @ motor pin B Motor faulty Replace TL4M Access Codes: Site Access: 7597 Factory Setup: 6759 18 CATERPILLAR 963K / 973D Loader User Settings Instructions ENTER SET UP MODE Start-Up Screen > Main Screen > Settings Button > Settings Screen > Site Access Button > Insert Pin > Site Menu To enter the Setup mode, press the SETTING button. Then enter SITE ACCESS MENU. Type in 4-number pin and press ENTER. BACK SET UP PARAMETERS Insert Pin = 7597 7597 Placing the BreatheSafe 200027 unit into Setup mode allows the adjustment of the following parameters: · Time (hours/minutes/seconds) · Date (day/month/year) · Pressure alarm setpoint · Preferred cabin pressure · Alarm delay/ intervals of alarm · Calibration and system settings · Resetting of the data logging · Service reminders interval gap · Reset current runtime between services · CO2 settings and alarms Enter Pin 12 3 45 6 78 9 CLEAR 0 ENTER USER SETTINGS INSTRUCTIONS 19 CATERPILLAR 963K / 973D Loader PRESSURE SETPOINT The pressure setpoint changes the pressure that the cabin will be maintained. INPRESS TS maintains the pre-set pressure within the cabin compared to outside. Enter Setup mode and select ADJUST SETPOINT button. Then, use the onscreen UP and DOWN buttons to change the corresponding fields. 8:30 22/04/23 25% Cabin Pressure 50Pa CO2 Level 200 PPM 1 Temperature 20°C 2 BACK Settings SYSTEM CHECK VIEW GRAPH EVENT LOG SITE ACCESS MENU BACK Enter Pin 1 2 3 3 4 5 6 4 7597 7 8 9 CLEAR 0 ENTER BACK Settings Page 1 NEXT STARTUP OPTIONS DOOR WINDOW SETTING PRESSURE SETPOINT CHECK RUNTIME DATE / TIME CO2 SETTING BACK Pressure Settings PRESSURE UNITS = Pascals Alarm Set Pressure Set Pressure 5 Point 20 Point 50 Alarm Delay 5 mins PRESSURE ALARM SETTING USER SETTINGS INSTRUCTIONS The mining industry benchmark for cabin pressure is 50 pascals and low-pressure is set at 20 pascals. After a delay the alarm will activate if cabin pressure remains below the pre-set value. Enter Setup mode and select ADJUST SETPOINT button. Then, use the onscreen UP and DOWN buttons to change the corresponding fields. 8:30 22/04/23 25% Cabin Pressure 50Pa CO2 Level 200 PPM 1 Temperature 20°C 2 BACK Settings SYSTEM CHECK VIEW GRAPH EVENT LOG SITE ACCESS MENU BACK Enter Pin BACK Settings Page 1 NEXT 1 2 3 STARTUP OPTIONS DOOR WINDOW SETTING PRESSURE SETPOINT 4 5 6 3 4 7597 7 8 9 CHECK DATE / CO2 RUNTIME TIME SETTING CLEAR 0 ENTER BACK Pressure Settings PRESSURE UNITS = Pascals Alarm Set Pressure Set Pressure 5 Point Point Alarm Delay 20 50 5 mins 20 CATERPILLAR 963K / 973D Loader SERVICE INTERVAL Use the onscreen UP and DOWN buttons to change the service interval setpoint. To reset the current runtime to zero, press the RESET CURRENT RUNTIME button and enter the site access pin. 8:30 22/04/23 25% Cabin Pressure 50Pa CO2 Level 200 PPM 1 Temperature 20°C 2 BACK Settings SYSTEM CHECK VIEW GRAPH EVENT LOG SITE ACCESS MENU BACK Enter Pin 1 2 3 3 4 5 6 4 7597 7 8 9 CLEAR 0 ENTER BACK Settings Page 1 NEXT STARTUP OPTIONS DOOR WINDOW SETTING PRESSURE SETPOINT CHECK RUNTIME DATE / TIME CO2 SETTING BACK Pressure Settings PRESSURE UNITS = Pascals CURRENT SET SERVICE 5 RUNTIME 700 INTERVAL 1000 DATE & TIME SETTINGS USER SETTINGS INSTRUCTIONS Change the recorded date displayed and measured by the INPRESS TS. 8:30 22/04/23 25% Cabin Pressure 50Pa CO2 Level 200 PPM 1 Temperature 20°C 2 BACK Settings SYSTEM CHECK VIEW GRAPH EVENT LOG SITE ACCESS MENU BACK Enter Pin BACK Settings Page 1 NEXT 1 2 3 STARTUP OPTIONS DOOR WINDOW SETTING PRESSURE SETPOINT 4 5 6 3 4 7597 7 8 9 CHECK DATE / CO2 RUNTIME TIME SETTING CLEAR 0 ENTER BACK Date/Time Settings NEXT PRESSURE UNITS = Pascals 5 HOUR MIN DAY MON YEAR 4 : 10 22 / 04 / 2023 21 CATERPILLAR 963K / 973D Loader PRESSURE ALARM BUZZER SETTING To disable the buzzer, toggle through to the ENABLED and DISABLED buttons. 8:30 22/04/23 25% Cabin Pressure 50Pa CO2 Level 200 PPM 1 Temperature 20°C 2 BACK Settings SYSTEM CHECK VIEW GRAPH EVENT LOG SITE ACCESS MENU BACK Enter Pin 1 2 3 3 4 5 6 4 7597 7 8 9 CLEAR 0 ENTER BACK Settings Page 1 NEXT STARTUP OPTIONS DOOR WINDOW SETTING PRESSURE SETPOINT CHECK RUNTIME DATE / TIME CO2 SETTING BACK Settings Page 2 BACK Alarm Buzzer Settings ALARM MUTE RESET ZERO SENSOR TEMP SETTING 5 BUZZER LOG FACTORY 6 SETTINGS SETTINGS SETUP ENABLED PRESSURE BUZZER ENABLED WINDOW BUZZER ENABLED CO2 PRIMARY BUZZER DISABLED DISABLED TEMPERATURE BUZZER DOOR BUZZER CALIBRATE ZERO SENSOR ALARM BUZZER SETTINGS Over long runtime, the 200027 may need recalibration. This screen allows the sensor to be recalibrated if more than 5 Pascals are out. To recalibrate, open windows and doors, turn off air conditioning, and any other device that may alter cabin pressure. Then, press the AUTO ZERO SENSOR button and leave the cabin while measuring. This process will reset the Zero Pressure. 8:30 22/04/23 25% Cabin Pressure 50Pa CO2 Level 200 PPM 1 Temperature 20°C 2 BACK Settings SYSTEM CHECK VIEW GRAPH EVENT LOG SITE ACCESS MENU BACK Enter Pin BACK Settings Page 1 NEXT 1 2 3 STARTUP OPTIONS DOOR WINDOW SETTING PRESSURE SETPOINT 4 5 6 3 4 7597 7 8 9 CHECK DATE / CO2 RUNTIME TIME SETTING CLEAR 0 ENTER BACK Settings Page 2 BACK Zero Sensor Adjustment ALARM MUTE RESET ZERO SENSOR TEMP SETTING 5 BUZZER LOG FACTORY 6 SETTINGS SETTINGS SETUP AUTO ZERO SENSOR Zero Pressure Adjust Pa 22 CATERPILLAR 963K / 973D Loader CO2 MODULE ENABLE/DISABLE Enable or disable to CO2 module used for measuring CO2 levels within the cabin. CO2 PRIMARY ALARM POINT CO2 SETTINGS The first alarm will sound when CO2 levels inside the enclosure reach this point. 8:30 22/04/23 25% Cabin Pressure 50Pa CO2 Level 200 PPM 1 Temperature 20°C 2 BACK Settings SYSTEM CHECK VIEW GRAPH EVENT LOG SITE ACCESS MENU BACK Enter Pin 1 2 3 3 4 5 6 4 7597 7 8 9 CLEAR 0 ENTER BACK Settings Page 1 NEXT STARTUP OPTIONS DOOR WINDOW SETTING PRESSURE SETPOINT CHECK RUNTIME DATE / TIME CO2 SETTING BACK CO2 Sensor Alarm Setting DISABLE CO2 SENSOR CO2 ALARM CO2 PRIMARY CO2 CRITICAL DELAY ALARM ALARM SETTING SETPOINT SETPOINT 5 2 Min 1000 PPM 2500 PPM ALARM MUTE DELAY 8:30 22/04/23 25% Cabin Pressure 50Pa CO2 Level 200 PPM 1 Temperature 20°C 2 BACK Settings SYSTEM CHECK VIEW GRAPH EVENT LOG SITE ACCESS MENU BACK Enter Pin BACK Settings Page 1 NEXT 1 2 3 STARTUP OPTIONS DOOR WINDOW SETTING PRESSURE SETPOINT 4 5 6 3 4 7597 7 8 9 CHECK DATE / CO2 RUNTIME TIME SETTING CLEAR 0 ENTER BACK CO2 Sensor Alarm Setting DISABLE CO2 SENSOR CO2 ALARM CO2 PRIMARY CO2 CRITICAL DELAY ALARM ALARM SETTING SETPOINT SETPOINT 5 2 Min 1000 PPM 2500 PPM ALARM MUTE DELAY 23 CATERPILLAR 963K / 973D Loader CO2 ALARM DELAY After CO2 (concentration in ppm) within the cabin reaches the 1000 ppm setpoint, the alarm will sound after this designated amount of time. The Alarm Delay adjusts the time between the INPRESS TS measuring CO2 concentration and sounding the alarm. Use the onscreen ADJUST buttons to change the corresponding fields. For example, press to toggle through Disabled / 1 10 minutes. 8:30 22/04/23 25% Cabin Pressure 50Pa CO2 Level 200 PPM 1 Temperature 20°C 2 BACK Settings SYSTEM CHECK VIEW GRAPH EVENT LOG SITE ACCESS MENU CO2 CRITICAL ALARM MUTE RESET CO2 SETTINGS The critical alarm is set at 2500 PPM and cannot be changed. The mute delay, however, can be configured. 8:30 22/04/23 25% Cabin Pressure 50Pa CO2 Level 200 PPM 1 Temperature 20°C 2 BACK Settings SYSTEM CHECK VIEW GRAPH EVENT LOG SITE ACCESS MENU BACK Enter Pin 1 2 3 3 4 5 6 4 7597 7 8 9 CLEAR 0 ENTER BACK Settings Page 1 NEXT STARTUP OPTIONS DOOR WINDOW SETTING PRESSURE SETPOINT CHECK RUNTIME DATE / TIME CO2 SETTING BACK CO2 Sensor Alarm Setting DISABLE CO2 SENSOR CO2 ALARM CO2 PRIMARY CO2 CRITICAL DELAY ALARM ALARM SETTING SETPOINT SETPOINT 5 2 Min 1000 PPM 2500 PPM ALARM MUTE DELAY BACK Enter Pin BACK Settings Page 1 NEXT 1 2 3 STARTUP OPTIONS DOOR WINDOW SETTING PRESSURE SETPOINT 4 5 6 3 4 7597 7 8 9 CHECK DATE / CO2 RUNTIME TIME SETTING CLEAR 0 ENTER BACK CO2 Sensor Alarm Setting DISABLE CO2 SENSOR BACK Critical Alarm Mute Timeout Adjustment DISABLE CO2 SENSOR CO2 ALARM CO2 PRIMARY CO2 CRITICAL DELAY ALARM ALARM SETTING SETPOINT SETPOINT 5 2 Min 1000 PPM 2500 PPM 6 SET MUTE TIMEOUT MINUTES 10 Mins ALARM MUTE DELAY 24 CATERPILLAR 963K / 973D Loader Data Download Setting up RS232 Connection 1 Plug the RS232/USB adaptor into a free USB port on your computer 2 Open up TeraTerm software. (TeraTerm is an open-source software tool and easily accessible via online search) 3 Use the following settings in TeraTerm: Serial and choose the correct port connection Hint: Click on the COMxx Port with the "USB serial Port" connection from the dropdown menu. Example: COM 21 This connection may be different on your computer. DATA DOWNLOAD 4 Click OK once the correct communication port has been identified. 5 Go to SETUP and click on Serial Port. 6 Change the COM ports to the following configuration: Baud Rate: 57600 Data: 8 bit Parity: EVEN Stop: 2 bit Flow Control: NONE 25 CATERPILLAR 963K / 973D Loader Data Download Setting up RS232 Connection 7 If required, you may choose to save the COM port settings. Go to Settings and clock save the setup. Hint: From the drop-down menu, click on the Save Setup. Name the file and save it. 8 The next time a download is required, you may restore the setup, and the required COM PORT settings will be loaded, ready to download the data file from the 200027 unit. DATA DOWNLOAD 9 From the drop-down menu, click on the Save setup. 10 Click Restore setup. 11 Choose the file name you have already saved. 26 CATERPILLAR 963K / 973D Loader Data Download Setting up RS232 Connection 12 From the drop-down menu, click on the Edit menu function. 13 Press "Select All". 14 Select "Copy table". Excel Data Instructions Unformatted DATA DOWNLOAD Open an Excel sheet and select the first cell A-1. Next, press and hold down the CTRL button on your keyboard and then press the letter V on the keyboard. This procedure will paste the copied data onto that Excel sheet. Once that data has been pasted onto the Excel sheet, click on `DATA' on the pull-down menu, followed by `Text to Columns'. Next, select `Delimited' on the newly opened window and click on Next. Only select the `Comma' button in the next window and then click `Finish'. Then, the Excel fields will update such that each piece of data is placed in the correct columns. The data is now ready for archiving. 15 Open a blank excel document and click on the page. Then, right-click to paste the copied table. 16 Fields are: Date, time, motor (volts) output, cabin pressure (Pa), cabin pressure pre-set (Pa), low cabin pressure alarm (Pa). Data Logging Formats BU No: xxxxxx (the device number unique to each unit and used for identification format = 000000) Time: [09:25] Date: [25/07/12] Pressure: 32 (Pascals) as an example. Alarm Type 0 = No alarm 1 = Low-pressure alarm 2 = Window open 3 = Door open 27 CATERPILLAR 963K / 973D Loader Express Warranty All BreatheSafe products carry a warranty against defects in materials or workmanship, provided the defects are not from factors outside of BreatheSafe's control (including neglect, lack of maintenance, improper installation or operation, unauthorized servicing repair, etc.). BreatheSafe will replace goods defected in material or workmanship at our Queensland factory or designated branch*. All parts deemed as failed or faulty must be returned to BreatheSafe for evaluation unless otherwise stated in writing. Note- Systems must be installed and commissioned as per BreatheSafe installation and commissioning instructions. Once commissioned, the online commissioning sheet must be filled in, extending the components warranty as below. In addition, the system must be serviced and maintained correctly and by trained and qualified personnel. This requisite includes BreatheSafe technicians, qualified automotive air-conditioning technicians, or qualified auto electricians. Warranty period Standard · 1 year or 10,000 hours (whichever occurs first). · Controllers 1 year no extended warranty option. · Warranty Period Extension when commissioning documents are registered online within 28 days of installation · Extended warranty** only offered if commissioning maximum pressure test reaches at least 250Pa. · Brushless motor fixed speed two years, or 10,000 hours (whichever occurs first). · Variable speed brushless motor 15,000 hours, or 3 years** (whichever occurs first). Must be supplied with a variable speed pressure controller, data download required for 3-year warranty option. Link to online Commissioning and Extended Warranty Registration form https://www.breathe-safe.com.au/commission/ What is not covered under Express Warranty? · Failures are due to incorrect application. · Damage resulting from neglect, misuse, lack of maintenance, improper installation, or operation, inappropriate or abnormal use, accidental or unauthorized servicing repair. · Failures are due to parts not being sold or approved by BreatheSafe. · Failures arising from any other cause that is not directly related to a defect in material or workmanship. This Express Warranty is VOID if the product is altered, modified, or used in the manner it was not designed for, also including unauthorized repairs, or using maintenance and repair parts other than those supplied by BreatheSafe. BreatheSafe responsibilities INPRESS TL WARRANTY If there is a defect in material or workmanship not caused by the excluded failures during the warranty period, BreatheSafe will either replace the defective goods at our Queensland factory, or designated branch. * Alternatively, BreatheSafe may elect to provide new replacement parts, BreatheSafe approved repair parts or assembled components needed to repair the defect. BreatheSafe reserves the right to provide a refund of the purchase price in lieu of replacement or repair at BreatheSafe's discretion. The replacement or repaired product will be sent to you freight prepaid by the customer or made available for pick-up on site. Users Responsibilities The customer should ensure that the system is maintained according to BreatheSafe service requirements and only authorized parts must be used to service and maintain BreatheSafe systems. In the event of a suspected warranty claim, BreatheSafe should be contacted in the first instance to arrange the repair or to assist with diagnosis. Claims should be made within one week of the repair. After contacting BreatheSafe, you may be required to deliver or send the parts to BreatheSafe's Queensland factory or designated branch. * Link to online Warranty claim form https://www.breathe-safe.com.au/warranty/ Exclusion and Limitations on Damages and Remedies This warranty is provided in lieu of all other warranties, written or oral, whether expressed by affirmation, promise, description, drawing, model, or sample. To the extent allowed by law, all warranties other than this warranty, whether express or implied, including implied warranties of fitness for a particular purpose, are disclaimed. The maximum liability of BreatheSafe under this warranty shall not exceed the original purchase price of the product. Interference with the equipment by or abuse, or by operating the equipment at ambient temperatures or with electrical power characteristics outside the ranges indicated in our specification shall be excluded from this warranty, as shall consequential damages. Excluded from any express warranty are costs incurred in relation to service outside our factory our designated service branch, including traveling time, waiting time, transport costs, mechanical and overtime payments required. As per Australian Consumer Law: You are entitled to choose a refund or replacement for major failures with goods. If a failure with the goods or service does not amount to a major failure, you are entitled to have the failure rectified in a reasonable time. If this is not done, you are entitled to a refund for the goods and to cancel the contract for the service and obtain a refund of any unused portion. You are also entitled to be compensated for any other reasonably foreseeable loss or damage from a failure in the goods or service. *This express warranty gives you specific legal rights, and you may also have other rights that vary from country to country. 28