User Guide for UNIVERSITY models including: RL2A Pump and Tank Selection, RL2A, Pump and Tank Selection, Tank Selection, Selection
4" Submersible Well Pumps - RL Series - Red Lion
Red Lion 602206, Model RJS-50-PREM, Shallow Well Jet Pump, 1/2 HP, 115/230 Volts, 1-1/4 FNPT Suction, 1 FNPT Discharge, 12.6 GPM Max, 150 ft Max Head, Manual
File Info : application/pdf, 2 Pages, 2.54MB
DocumentDocumentuniversity.redlionproducts.com 1-2-3 EASY GUIDE FOR PUMP & TANK SELECTION 1 DEPTH TO THE PUMPING WATER LEVEL 025 feet: Shallow well or convertible jet pump, install in shallow PUMP CHART Read across the top of the chart for correct pumping water level (single pipe) configuration. in feet. Read down the side for correct flow required (gpm). 2590 feet: Convertible jet pump, installed in deep (two pipe) The letter(s) corresponds to the minimum recommended pump configuration or deep well submersible pump. options. Higher horsepower models of the same categories may 0250 feet: Deep well submersible pump. be substituted for jet pumps. 250+ feet: Call The Technical Service Line: 1.888.885.9254 "Pumping water level" is the depth to the water while the well is being pumped. It is usually deeper than the depth to the water Flow Req. (GPM) 5 Pumping Water Level in Feet 15 25 50 80 100 150 200 250 when the pump is not running. For a lake or cistern installation, it is the depth to the surface of the water. For Jet pumps, it is the vertical distance from the pumping water level to the suction opening of the pump. For Submersible pumps, it is the vertical distance from the pumping water level to the point of water usage. New installation information is available on the Well Driller's 3 A,D A,D A,D,G D,G D,G G G,H H,I I 4 A,D A,D A,D,G D,G E,G G,H G,H H,I I 5 A,D A,D A,E,G D,G F,G G,H G,H H,I I 6 A,D A,D B,E,G D,G G G,H H I I 7 A,D A,D B,E,G F,G G,H G,H H I I 8 A,D A,E C,F,G G G,H G,H H I I 9 A,D A,E C,G G G,H G,H I I J 10 A,D B,E C,G G,H G,H G,H I I J 11 A,E B,E G G,H H H I J J Report. For replacement installations, use the equivalent style and horsepower pump, providing it was suitable when it was operational. NOTE: A foot valve or check valve is required for proper operation of any system. The suction line must extend at least 5' below the pumping water level and be at least 10' above the well bottom. 12 A,E C,E G G,H H H I,J J J 13 B,E C,F G G,H H,I I,J J J J 14 B,E C,F G I I,J J J J J 15 B,E C 16 C,E C IJ 17 C,E C NOTE: For depths greater than 250', consult tech support Shallow Well Convertible Deep Well Jet Pumps Jet Pumps Submersible Pumps 2 HOW MUCH WATER IS REQUIRED The gpm (gallons per minute) of the pump must equal the total number of fixtures. Fixtures include all faucets, toilets, and water A = RJS-50-PREM ½ hp D = RJC-50-PREM ½ hp B = RJS-75-PREM ¾ hp E = RJC-75-PREM ¾ hp C = RJS-100-PREM 1 hp F = RJC-100 1 hp G = RL12G05 ½ hp H = RL12G07 ¾ hp I = RL12G10 1 hp J = RL12G15 1½ hp consuming appliances (do not include water treatment appliances, such as a hot water tank or water filter). Example: A house with one full bathroom (sink, tub/shower, toilet), kitchen sink, basement sink, outside faucet, washing machine, and dishwasher would require 8 gpm. 3 MINIMUM WELL DIAMETER 2½" Jet pumps in shallow well applications (depth less than 25') should be installed using 1-1/4" suction piping with a foot valve. 4" Convertible jet pumps used in deep well applications (depth greater than 25') and deep well submersible pumps. TANK CHART NOTE: Refer to Step 2 above. The easy way to size a tank is take the gpm system requirement that you determined in Step 2, multiply by 3 and go to the next largest tank size. Example: 8 gpm x 3 = 24 gallons therefore use an RL34 tank. Model RL2A RL4A RL6AH RL14AH RL14A RL20A RL34A RL44A Gallons 2.0 4.5 6.0 14.0 14.0 20.0 34.0 44.0 Drawdown 0.7 1.5 1.9 4.8 4.9 7.2 10.8 12.7 Fixtures 1 4 4 6 11 14 university.redlionproducts.com TYPICAL INSTALLATIONS SHALLOW WELL JET PUMP (DOWN TO 25') Suitable for applications where the pumping water level does not exceed 25'. Requires a single 1-1/4" suction pipe. May be used in wells 2" or larger in diameter. DRILLED WELL Pressure Priming Switch Plug Drain Plug Suction Pipe Pre-charged Tank DRIVEN WELL Pressure Priming Switch Plug Service Valve To Service Drain Plug Check Valve Suction Pipe Pre-charged Tank Service Valve To Service Well Vent Well Seal Well Casing Foot Valve Well (Sand) Point To complete installation, the following is required: · Jet pump · Pressure tank · Pump-to-tank fittings · 1-1/4" suction piping · Foot valve or check valve CONVERTIBLE JET PUMP (DEEP WELL CONFIGURATION DOWN TO 90') Suitable for applications where the pumping water level does not exceed 90'. Requires a double suction pipe. May be used in wells 4" or larger in diameter. Pre-charged Tank Pressure Switch Priming Plug Control Valve Service Valve To Service Drain Plug 1" Pressure Return Pipe 1-1/4" Suction Pipe Well Vent Well Seal Well Casing Injector Foot Valve To complete installation: · Jet pump; includes pressure switch, flow control valve, injector (installed in the well) · Pressure tank · Pump-to-tank fittings · 1-1/4" suction piping and 1" pressure return piping · Foot valve CONVERTIBLE JET PUMP (SHALLOW WELL CONFIGURATION DOWN TO 25') Suitable for applications where the pumping water level does not exceed 25'. Requires a single 1-1/4" suction pipe. May be used in wells 2-1/2" or larger in diameter. Pressure Switch Priming Plug Drain Plug Suction Pipe Well Vent Well Seal Well Casing Foot Valve Pre-charged Tank Control Valve Injector Service Valve To Service To complete installation: · Jet pump; includes pressure switch, · Pump-to-tank fittings flow control valve, injector · 1-1/4" suction piping (installed on the pump) · Foot valve or check valve · Pressure tank (for driven well) DEEP WELL SUBMERSIBLE PUMP (DOWN TO 250') Suitable for applications where the pumping water level does not exceed 250'. May be used in wells 4" or larger in diameter. Frost Line Pitless Adapter Discharge Pipe Torque Arrester Well Pump Pressure Switch Pre-charged Tank Check Pressure Gauge Valve To Service To complete installation: · Submersible pump sub-pac; includes pressure switch, pressure gauge, service tee, relief valve, sub cable, built-in check valve · Pressure tank · Torque arrester · Well seal or pitless adapter · 1" discharge piping