User Guide for UNIVERSITY models including: RL2A Pump and Tank Selection, RL2A, Pump and Tank Selection, Tank Selection, Selection

Easy Guide to Pump & Tank Selection

4" Submersible Well Pumps - RL Series - Red Lion

Red Lion 602206, Model RJS-50-PREM, Shallow Well Jet Pump, 1/2 HP, 115/230 Volts, 1-1/4 FNPT Suction, 1 FNPT Discharge, 12.6 GPM Max, 150 ft Max Head, Manual


File Info : application/pdf, 2 Pages, 2.54MB

PDF preview unavailable. Download the PDF instead.

Red Lion 602206 Easy Guide to Pump and Tank Selection
university.redlionproducts.com

1-2-3 EASY GUIDE FOR PUMP & TANK SELECTION

1

DEPTH TO THE PUMPING WATER LEVEL
0­25 feet: Shallow well or convertible jet pump, install in shallow

PUMP CHART
Read across the top of the chart for correct pumping water level

(single pipe) configuration.

in feet. Read down the side for correct flow required (gpm).

25­90 feet: Convertible jet pump, installed in deep (two pipe)

The letter(s) corresponds to the minimum recommended pump

configuration or deep well submersible pump.

options. Higher horsepower models of the same categories may

0­250 feet: Deep well submersible pump.

be substituted for jet pumps.

250+ feet: Call The Technical Service Line: 1.888.885.9254 "Pumping water level" is the depth to the water while the well is being pumped. It is usually deeper than the depth to the water

Flow

Req. (GPM)

5

Pumping Water Level in Feet 15 25 50 80 100 150 200 250

when the pump is not running. For a lake or cistern installation, it is the depth to the surface of the water. For Jet pumps, it is the vertical distance from the pumping water level to the suction opening of the pump. For Submersible pumps, it is the vertical distance from the pumping water level to the point of water usage. New installation information is available on the Well Driller's

3 A,D A,D A,D,G D,G D,G G G,H H,I I

4 A,D A,D A,D,G D,G E,G G,H G,H H,I I

5 A,D A,D A,E,G D,G F,G G,H G,H H,I I

6

A,D A,D B,E,G D,G G G,H H

I

I

7

A,D A,D B,E,G F,G G,H G,H H

I

I

8

A,D A,E C,F,G G G,H G,H H

I

I

9

A,D A,E C,G G G,H G,H I

I

J

10 A,D B,E C,G G,H G,H G,H I

I

J

11 A,E B,E G G,H H H I J J

Report. For replacement installations, use the equivalent style and horsepower pump, providing it was suitable when it was operational. NOTE: A foot valve or check valve is required for proper operation of any system. The suction line must extend at least 5' below the pumping water level and be at least 10' above the well bottom.

12 A,E C,E G G,H H H I,J J J

13 B,E C,F G G,H H,I I,J J J J 14 B,E C,F G I I,J J J J J

15 B,E C 16 C,E C

IJ

17 C,E C

NOTE: For depths greater than 250', consult tech support

Shallow Well

Convertible

Deep Well

Jet Pumps

Jet Pumps

Submersible Pumps

2 HOW MUCH WATER IS REQUIRED The gpm (gallons per minute) of the pump must equal the total number of fixtures. Fixtures include all faucets, toilets, and water

A = RJS-50-PREM ½ hp D = RJC-50-PREM ½ hp

B = RJS-75-PREM ¾ hp E = RJC-75-PREM ¾ hp

C = RJS-100-PREM 1 hp

F = RJC-100 1 hp

G = RL12G05 ½ hp H = RL12G07 ¾ hp I = RL12G10 1 hp J = RL12G15 1½ hp

consuming appliances (do not include water treatment appliances,

such as a hot water tank or water filter). Example: A house

with one full bathroom (sink, tub/shower, toilet), kitchen sink,

basement sink, outside faucet, washing machine, and dishwasher

would require 8 gpm.

3

MINIMUM WELL DIAMETER
2½" ­ Jet pumps in shallow well applications (depth less than 25')

should be installed using 1-1/4" suction piping with a foot valve.

4" ­ Convertible jet pumps used in deep well applications

(depth greater than 25') and deep well submersible pumps.

TANK CHART
NOTE: Refer to Step 2 above. The easy way to size a tank is take the gpm system requirement that you determined in Step 2, multiply by 3 and go to the next largest tank size. Example: 8 gpm x 3 = 24 gallons ­ therefore use an RL34 tank.

Model RL2A RL4A RL6AH RL14AH RL14A RL20A RL34A RL44A

Gallons 2.0 4.5 6.0 14.0 14.0 20.0 34.0 44.0

Drawdown 0.7 1.5 1.9 4.8 4.9 7.2 10.8 12.7

Fixtures 1 4 4 6 11 14

university.redlionproducts.com

TYPICAL INSTALLATIONS

SHALLOW WELL JET PUMP (DOWN TO 25')
Suitable for applications where the pumping water level does not exceed 25'. Requires a single 1-1/4" suction pipe. May be used in wells 2" or larger in diameter.

DRILLED WELL
Pressure Priming Switch Plug
Drain Plug Suction Pipe

Pre-charged Tank

DRIVEN WELL
Pressure Priming Switch Plug

Service Valve

To Service

Drain Plug Check Valve
Suction Pipe

Pre-charged Tank
Service Valve To Service

Well Vent Well Seal Well Casing Foot Valve

Well (Sand) Point

To complete installation, the following is required: · Jet pump · Pressure tank · Pump-to-tank fittings · 1-1/4" suction piping · Foot valve or check valve

CONVERTIBLE JET PUMP (DEEP WELL CONFIGURATION DOWN TO 90')

Suitable for applications where the pumping water level does not

exceed 90'. Requires a double suction pipe. May be used in wells

4" or larger in diameter.

Pre-charged Tank

Pressure Switch

Priming Plug

Control Valve

Service Valve To Service

Drain Plug 1" Pressure Return Pipe 1-1/4" Suction Pipe Well Vent Well Seal Well Casing
Injector
Foot Valve
To complete installation: · Jet pump; includes pressure switch, flow control valve,
injector (installed in the well) · Pressure tank · Pump-to-tank fittings · 1-1/4" suction piping and 1" pressure return piping · Foot valve

CONVERTIBLE JET PUMP (SHALLOW WELL CONFIGURATION DOWN TO 25')
Suitable for applications where the pumping water level does not exceed 25'. Requires a single 1-1/4" suction pipe. May be used in wells 2-1/2" or larger in diameter.

Pressure Switch

Priming Plug

Drain Plug Suction Pipe
Well Vent Well Seal Well Casing
Foot Valve

Pre-charged Tank

Control Valve
Injector

Service Valve To Service

To complete installation:

· Jet pump; includes pressure switch, · Pump-to-tank fittings

flow control valve, injector

· 1-1/4" suction piping

(installed on the pump)

· Foot valve or check valve

· Pressure tank

(for driven well)

DEEP WELL SUBMERSIBLE PUMP (DOWN TO 250')
Suitable for applications where the pumping water level does not exceed 250'. May be used in wells 4" or larger in diameter.

Frost Line Pitless Adapter Discharge Pipe
Torque Arrester Well
Pump

Pressure Switch

Pre-charged Tank

Check

Pressure Gauge

Valve

To Service

To complete installation: · Submersible pump sub-pac; includes pressure switch, pressure
gauge, service tee, relief valve, sub cable, built-in check valve · Pressure tank · Torque arrester · Well seal or pitless adapter · 1" discharge piping



References

Adobe PDF Library 17.0 Adobe InDesign 19.0 (Macintosh)