ultraflo-h2o-series-manual
UFM-H2O Series Ultrasonic Flow Meter (Battery Operated)
UltraFlo® H2O Series
Ultrasonic Flow Meter
Operating Manual
www.iconprocon.com | sales@iconprocon.com | 905.469.9283

UFM-H2O Series Ultrasonic Flow Meter (Battery Operated)

Table of Contents

Safety Information

03

Technological Progress

03

Introduction

03

Technical Specifications

04

Installation Instructions

05

Correct Install Position

05

Dimensions

06

Flow Ranges

07

Performance Error Curve

07

Display Instructions

08

Key Description

08

Menu Instruction

09

Detailed Menu

10

Calibration Method

14

Communication

14

Warranty, Returns & Limitations

15

www.iconprocon.com | sales@iconprocon.com | 905.469.9283 02

UFM-H2O Series Ultrasonic Flow Meter (Battery Operated)

Safety Information
Warning | Caution | Danger Indicates a potential hazard. Failure to follow all warnings may lead to equipment damage, injury, or death
Note | Technical Notes Highlights additional information or detailed procedure.

IMPORTANT! indicates situations or cases which, if not avoided, could result in damage or failure of the Products equipment.
Do Not Use Tools Use of tool(s) may damage product beyond repair and potentially void product warranty.

Intended Use
The flow meter UltraFlo® should only be used for measuring the flow of pure, homogeneous liquids. The UltraFlo® is not intended for use in medical applications. The volume flow meter UltraFlo® is built in accordance with industry standard EN 61010 regulations (corresponds to VDE 0411 "Safety specifications for electrical measurement, control and laboratory devices"). The manufacturer is not liable for any injury, damage or harm due to inappropriate or unintended use or modifications of the flow meter. Conversions and/or changes to the flow meter may only be made, if they are expressly performed in accordance with the operating instructions in this operating manual.
Personnel for Installation, Commissioning and Operation
Assembly, electrical installation, commissioning and maintenance of the flow meter must be carried out by qualified, trained personnel. The qualified personnel must have read and understood the operating instructions in this operating manual and must follow the operating instructions in this manual. The installer has to ensure that the flow meter is correctly connected according to the electrical connection diagrams in this operating manual. Serious injury or death from electric shock may occur if wiring, installation, disassembly or removal of wires is performed while electrical power is energized
Technological Progress
The manufacturer reserves the right to revise, alter, or modify the flow meter to the most current technology without special prior notice. Further information about the latest updates and potential additions to these operating instructions are available from www.iconprocon.com
Introduction
The UltraFlo® H2O series ultrasonic water meter is a new type of water meter specially designed for agricultural irrigation, garden management and water resources monitoring. The water meter has some advantages, such as low cost, high measurement accuracy, low power consumption, stable and reliable operation and so on. The thickness of the water meter is only 2 inches(50.8mm), which saves installation space, and the IP68 scheme is adopted for all parts so that the water meter can be used in various harsh environment. The uniquestructure of the water meter makes the measurement basically free from the influence of water quality and pressure loss, which is a major breakthrough in the agricultural irrigation water measurement. The UltraFlo® H2O Series Flow Meter utilizes ultrasonic technology to maximize water efficiency. It has no moving parts, and is lightweight making it an excellent choice for plastic piping systems. The UltraFlo® H2O all plastic design provides excellent protection against corrosive environments and flooded wet conditions
www.iconprocon.com | sales@iconprocon.com | 905.469.9283
03

UFM-H2O Series Ultrasonic Flow Meter (Battery Operated)

Technical Specifications

General Executive Standard Accuracy Rating Measurable Fluid Fluid Temperature Work Environment Pressure Pressure Loss Display
Spot Display
Data Storage
Flow Measurement Cycle
Output
Communication Interface
Output Signal Input Power Built-in Batteries Power External Power Power Consumption Materials Measuring Pipe Sensor Protection Cover Sensitivity Grade Sensitivity Grade of Upstream Flow Field Sensitivity Grade of Downstream Flow Field Climate & Mechanical Environment Safety Grade Electromagnetism Compatibility Grade Protection Grade

ISO4064-2014, GBT778-2018 2 Class Water, Sewage, Seawater (Other Liquid need be Customized), Liquid full of Pipeline 0.1-30 °C Temperature: -30-45°C, Ghumidity: 100% ( RH ) 200Psi No pressure Loss

9 Digital Accumulate Flow Display, 6 Digital Instantaneous Flow Display, Arious Condition Prompt symbols and units.
Ferroelectric Storage Parameters usage, recording accumulate flow of 31months and 31days
Measurement Condition: 1Time/Second (settable); Authentication Condition: 4Time/Second

RS485 / USART / Infrared interface; M-BUS Alternatives, 4G moudle | NB-lot Wireless Transmission
OCT Alternatives

24VDC Lithium Batteries 8-24VDC Standard Condition < 30uA, each battery can work over 15 years constantly

Nylon + Glass Fiber PEEK ABS

U5 D3 C Class E2 Class IP68

www.iconprocon.com | sales@iconprocon.com | 905.469.9283 04

UFM-H2O Series Ultrasonic Flow Meter (Battery Operated)

Installation Instructions

When installing the meter, the upstream straight pipe line should be 5D, downstream straight pipe line should be 3D, 20D from the pump (D is the pipe diameter), and ensure full pipe.

1

2

62.8mm

{ Cut 62.8mm of pipe

water meter thickness 50.8mm 2pcs seal gasket thickness 6mm

3

4

Install Companion Flange

Flow Direction

Install water meter with 3 screws to fix the flange averagely, then spot welding.
Correct Install Position
Correct Installation Point

Install with seal gasket, and tighten bolts. Make sure the direction arrow on water meter is
as the same as the direction of flow.
Wrong Installation Point

DN80

5D

DN80

5D

3D

Lowest Point of the Pipe Line, Full Pipe. Upstream Straight Pipe Line >= 5 Pipe Diameters

Highest Point of the Pipe Line, Pipe would not be Full. Upstream Straight Pipe Line >= 3 Pipe Diameters
www.iconprocon.com | sales@iconprocon.com | 905.469.9283 05

UltraFlo® H2O Series Ultrasonic Flow Meter (Battery Operated)
Dimensions Flanged Connection

Nominal Diameter (mm | in)

Dimensions (mm)

L

H1 H2 W1 W2 D

DN50 | 2" DN80 | 3" DN100 | 4" DN125 | 5" DN150 | 6" DN200 | 8" DN250 | 10" DN300 | 12" DN350 | 14" DN400 | 16" DN450 | 18" DN500 | 20"

200 82.5 180 82.5 108 165 225 100 197 100 108 200 250 110 207 110 110 220 275 125 220 125 125 250 300 142.5 233 142.5 142.5 285 350 170 257 170 170 340 450 200.5 284.5 200.5 200.5 405 500 230 310 230 230 460 550 260 350 260 260 520 600 290 380 290 290 580 700 320 410 320 320 640 800 357.5 447.5 357.5 357.5 715

Flange Dimensions (mm)

D1 D2

Bolt Hole Dia * Qty

Flange Thickness,C

125 102

18*4

19

160 138

18*8

20

180 158

18*8

22

210 188

18*8

22

240 212

22*8

24

295 268

22*12

26

355 320

26*12

29

410 378

26*12

32

470 438

26*16

35

525 490

30*16

38

585 550

30*20

46

650 610

33*20

46

Pressure Class
16 16 16 16 16 16 16 16 16 16 16 16

Threaded Connection

Nominal Diameter (mm | in)

Dimensions (mm)

Pressure

Grade

L

H1 H2 W1 W2

(Psi)

DN15 | ½"

165 14 123 57 130

DN15 | ½"

195 18 125 57 130

DN25 | 1"

160 22 127.5 57 130

DN32 | 1 ¼" 180 25 130 57 130

DN40 | 1 ½" 200 33.5 134 57 130

232.06 232.06 232.06 232.06 232.06

www.iconprocon.com | sales@iconprocon.com | 905.469.9283 06

UFM-H2O Series Ultrasonic Flow Meter (Battery Operated)

Flow Ranges

Nominal Diameter (mm | in)

Turndown Ratio (R)

Starting Flowrate

Minimum Flow Q1

Flow (GPM)
Demarcation Flow Q2

Common Flow Q3

Overload Flow Q4

Mono Industrial Grade Small Diameter Water Meter (R=200)

DN15 | ½"

200

DN20 | ¾"

200

DN25 | 1"

200

DN32 | 1 ¼"

200

DN40 | 1 ½"

200

0.0136 0.0220 0.0347 0.0880 0.1378

0.0550 0.0880 0.1386 0.3522 0.5503

0.0880 0.1408 0.2219 0.5635 0.8805

11.007 17.611 27.738 70.445 110.071

13.758 22.014 34.6725 88.057 137.589

Two Channel Large Diameter Water Meter (R=100)

DN50 | 2"

100

DN80 | 3"

100

DN100 | 4"

100

DN150 | 6"

100

DN200 | 8"

100

DN250 | 10"

100

DN300 | 12"

100

DN400 | 16"

100

DN450 | 18"

100

DN500 | 20"

100

0.440 1.100 1.761 4.402 6.934 11.007 17.611 27.517 27.517 44.028

1.761 4.402 7.044 17.6114 27.738 44.028 70.445 110.071 110.071 176.114

2.817 7.044 11.271 28.178 44.380 70.445 112.713 176.114 176.114 281.783

176.114 440.286 704.458 1761.147 2773.806 4402.867 7044.588 11007.168 11007.168 17611.470

220.143 550.358 880.573 2201.433 3467.258 5503.584 8805.735 13758.961 13758.961 22014.337

Four Channel Large Diameter Water Meter (R=200)

DN80 | 3"

200

0.550

2.201

DN100 | 4"

200

0.880

3.352

DN150 | 6"

200

DN200 | 8"

200

DN250 | 10"

200

2.201 3.469 5.503

8.805 13.869 22.014

DN300 | 12"

200

8.805

35.222

DN350 | 14"

200

8.805

35.222

DN400 | 16"

200

13.758

55.035

DN450 | 18"

200

13.758

55.035

DN500 | 20"

200

22.014

88.057

3.522 5.635 14.089 22.190 35.222 56.356 56.356 88.057 88.057 140.891

440.286 704.458 1761.147 2773.806 4402.867 7044.588 7044.588 11007.168 11007.168 17611.470

550.358 880.573 2201.433 3467.258 5503.584 8805.735 8805.735 13758.961 13758.961 22014.337

www.iconprocon.com | sales@iconprocon.com | 905.469.9283 07

UFM-H2O Series Ultrasonic Flow Meter (Battery Operated)
Performance Error Curve

Display Instructions

Ult rason ic

IRD C

Water Meter

GAL

8

8

8

8

8

8

8

8

8

8

L m

3

ft 3 AFk W .hGJk BTU RT
Out1Out2 4 -20m A M 88

GPM Pa°Cft 3/ hAF/ym L/sk CGJ/ h°F

8

888

88

kW L/m

m 3/ h

5. 0
2. 0 0
-2. 0 -5. 0

Q1 Q2

Error Curve

Q3 Q4

Infrared Interface

6 Digital Instantaneous Flow Display

UFM-H2O Series
Ultrasonic Flow Meter

9 Digital Accumulate Flow Display Touch Button

Alarm/Error Leak Detector Wireless Communication In Communication Permanent Fault Valve Open Battery Low Connention 4-20mA Current Loop Connection Out1Out2 Pulse Output

Key Description

There are two capacitive touch keys on the display, which are indicated as

and

.

Scroll UP; Change Number; Active Keys and Display (press for 5 seconds).

Scroll DOWN; Move Modify Cursor.

Slide from

to , Enter to next step menu; confirm the operation.

Slide from

to , Quit the current menu.

www.iconprocon.com | sales@iconprocon.com | 905.469.9283

w w w . levelprosales.com

08

UFM-H2O Series Ultrasonic Flow Meter (Battery Operated)

Menu Instruction

There are 4 main menu options for the water meter

In then menu M-0, press the modifying key

will enter in the sub menu M-01, Press

will display sub menu M-02. Press

will return to the main menu M-0.

M-0 : Measured value display and working status, referred to as DISP

M00

Display instantaneous flow and positive cumulative flow

M01

Display instantaneous heat and positive / negative cumulative heat (heat meter)

M02

Display water pressure and water temperature (multi-function water meter)

M03

Display supply water temperature TI and return water temperature T2 (heat meter)

M04

Displays battery voltage and total signal strength and signal quality

M05

Displays total propagation time (microseconds) and propagation time difference (nanoseconds)

M06

Display date time week

M07

Auto Verification Window

M08

Manual Verification Window

M09

Display software version number and instrument serial number

M0A

Show Full Screen

M-1 : Pipeline parameters and historical query, referred to as CHEC

M10

Enter the password to enter the submenu

M11

Display the number of sound channels, inner diameter and distance between probes

M12

Display sample time, damping coefficient, angle coefficient

M13

Show negative accumulation

M14

Query the daily net cumulative amount

M15

Query the monthly net cumulative amount

M17

Display total working time and failure working time

M18

Display production date (calibration writing), calibration job number (increase calibration level)

M-2 : Communication settings, referred to as COM

M21

Set date time week

M23

Set RS485 communication protocol

M24

Set RS485 , communication address

M25

RS485/MBUS communication baud rate verification

M26

Communication data display for debugging

M-3 : Flow Rate Setting and Modification, for short CORR

M32

Display current zero value, low flow excision value

M33

Set instrument coefficient

M34

Set low flow excision value

M35

Reset accumulator (modify cumulant)

M36

Display instantaneous flow rate and static state zero setting

M39

Set the scale of the meter's positive/negative cumulative flow retention

M3B

Manually set the traffic type for the default display window M00

www.iconprocon.com | sales@iconprocon.com | 905.469.9283

09

UFM-H2O Series Ultrasonic Flow Meter (Battery Operated)

Detailed Menu Main Menu

M-0

Measured value display and working status DISP

M-1

Pipeline parameters and history query Chec

M-2

Communication Settings Com

M-3

Flow, heat setting and correction Corr

M-0 Measured Value Display and Working Status

Displays instantaneous flow and positive cumulative flow (the default display window of the water meter)

The First Row : Instantaneous Flow

M00

The Second Row : Positive Cumulative flow

The water meter displays the window by default, and it will automatically jump to this window if there is no operation for two minutes. The position of the decimal point of the unit and cumulative quantity is modified and set with a special parameter setting software.

Displays instantaneous heat and positive / negative cumulative heat (heat meter default display window, water meter does not have this window)

M01

The First Row : Instantaneous Heat

The Second Row : Positive / Negative Cumulative Heat

The heat meter displays the window by default, and it will automatically jump to this window if there is no operation for two minutes.

Displays water pressure and water temperature (multi-function water meter displays

M02

this window)

Line 1: Water pressure / water temperature

Displays water supply temperature T1 and return water temperature T2 (heat meter display window, water meter does not have this window) M03 First Line : supply water temperature T1 The second Line : return water temperature T2

www.iconprocon.com | sales@iconprocon.com | 905.469.9283 10

UFM-H2O Series Ultrasonic Flow Meter (Battery Operated)

M04
M05 M06 M07
M08 M09 M0A

Displays battery voltage and total signal strength and signal quality
First Line : Instantaneous Flow Second Row : Total Signal Strength / Signal Quality
The two digits on the left side of the second line show the total signal strength, the larger the value, the greater the signal strength, and the maximum value is 90 50 means it cannot be used;
50 Signal strength 65, the signal is good and can be used normally; when > 65 , the signal is excellent.
Q value) of each channel in turn , the larger the value, the better the signal quality, the maximum value is 9 . Usually the Q value is 9 . The number of digits displayed represents the number of channels of the meter. For example, 9999 is displayed , which means that the meter is four-channel and the signal quality of the four channels is 9 . If the value of any one of the four digits is less than 9 , this channel will not participate in the measurement. If all are less than 9 and greater than 6 ,Then measure the maximum value channel; stop measuring when all are less than 6 .

Shows the total propagation time / time difference
First Line : Total Propagation Time (microseconds) Second Row : Propagation Time Difference (nanoseconds)

Display time, date, week
First Line : Hours - Minutes - Seconds Second Row : Year - Month - Day / week

Automatic Verification Window

M07 window, type "

" to display Enter , and then type "

" to confirm and enter

the automatic verification state. Calibrate using the start-stop method . No key operation is

required during calibration.

a : Indicates that there is a water flow passing through, wait for the water flow to stop before starting the test.
b : Indicates that the water flow is still, waiting for the test or the end of the test. c : Indicates that there is water passing through and the test is in progress.

Note : At the beginning of each verification, the cumulative value is automatically cleared. The cumulative amount generated by the test does not affect the cumulative amount generated by normal metering.

Manual verification window

M08 window, type " verification. Key in " calibration state.

" to display Enter , and then type "

" to confirm the manual

" , and b is displayed , indicating that it has entered the

"

" again , and c is displayed , indicating that the test is over.

Note: At the beginning of each verification, the cumulative value is automatically cleared. The cumulative amount generated by the test does not affect the cumulative amount generated by normal metering.

Displays Software Version Number & Instrument Serial Number
First Line : Software Version Number Second Row : Instrument Serial Number

Show full screen Display all segment codes of LCD for checking.

www.iconprocon.com | sales@iconprocon.com | 905.469.9283 11

UFM-H2O Series Ultrasonic Flow Meter (Battery Operated)

M-1 Pipeline Parameters & Historical Query

Enter the Password to Enter the Submenu

After pressing "

" to exit from any submenu in the M-0 main menu , enter the

M10

password:

"1111" and confirm to enter the main menu cycle. Press the " " key to select the main menu, and enter the submenu of the main menu after confirmation.

Displays the number of sound channels, inner diameter, distance between probes

M11

First Line : number of channels

Second Row : Inner diameter / Probe spacing

Display sampling time, damping coefficient, angle coefficient

M12

First Line : The actual sampling Interval time

Second Line : Damping coefficient / set sampling interval time / angle coefficient

Shows Negative Cumulative Flow M13
Second Line : Display Negative Cumulative Flow

Query Daily Net Cumulative Amount

M14

First Line : Display the query Year - Month - Day

Second Line : Display the Net Cumulative Amount of the Day

You can turn the page to check the daily net cumulative amount of the previous 32 days.

Query Monthly Net Cumulative Amount

M15

First Line : display the query Year - Month

Second Line : display the net cumulative amount of the current month

You can turn the page to check the net accumulation in the previous 32 months.

M17

Shows Total Working Hours

Displays the total working hours for normal metering.

Displays Production Date, Calibration Job Number & Instrument Grade

M18

First Line : Display the Production Date

Second Line : Display the Calibration job Number / Instrument Level

M-2 Communication Settings

Set Date, Time, Week

M21

First Line : Hourminute - Second

Second Line : year - month - day / week

Set RS485 Letter of Agreement

M23

All communication protocols are adaptive, no need to set.

M24

Set RS485 Contact Address

Set Mailing Address Code

www.iconprocon.com | sales@iconprocon.com | 905.469.9283 12

UFM-H2O Series Ultrasonic Flow Meter (Battery Operated)

M25

RS485/MBUS Communication Baud Rate, Parity

Set wave communication baud rate, parity bit

M26

Communication data display for M26 debugging

Used to verify Communication Tests.

M-3 Flow / Heat Setting and Correction

Displays the Current Zero Point Value, Low Flow Cutoff Value

M32

First Line : current zero point value (time difference)

Second Line : low flow cutoff value flow

Set Meter Factor

M33

The factory default is 1 . To change the correction coefficient of the instrument, it is

necessary to apply for a serial number calculation type password from the dealer.

Set Low Flow Cutoff value M34
Second Line : Set the low flow cutoff value

M35 M36 M37 M38 M39 M3A

Accumulator Clear (Modify Accumulator)
The cumulative flow can be reset or modified, and it is necessary to apply for a serial number calculation type password from the dealer.

Set Instantaneous Flow, Static Zero
You can choose do static zero setting, Undo to cancel static zero setting and restore factory zero. When setting zero, the instantaneous flow rate cannot be greater than Q1 .

Manual Correction of Water Supply Temperature T1

Press the "

" key to increase the temperature by 0.1°C each time , and press the

" " to decrease the temperature by 0.1°C each time . After modification, press "

" to confirm. It is necessary to apply for a serial number calculation type password from

the dealer.

Manual Correction of Return Water Temperature T2

Press the " " key to increase the temperature by 0.1°C each time , and press the "

" to decrease the temperature by 0.1°C each time . After modification, press "

"

to confirm. It is necessary to apply for a serial number calculation type password from

the dealer.

Display / Set Flow Decimal Places

Display the number of decimal places reserved for the positive / negative cumulative

flow of the water meter Press "

" to enter the operation menu, and see the number

on the lower left flashing. Press " " to increase one decimal each time; press " " to

decrease one decimal each time. After modification, press "

" to confirm.

Display / set heat decimal places

Displays the number of decimal places for positive / negative cumulative heat retention

of the heat meter Press "

" to enter the operation menu, and see the number on

the lower left flashing. Press " " to increase one decimal each time; press " " to

decrease one decimal each time. After modification, press "

" to confirm.

www.iconprocon.com | sales@iconprocon.com | 905.469.9283 13

UFM-H2O Series Ultrasonic Flow Meter (Battery Operated)

M3B M3C

Manually Set the Default Display Window M00 Traffic Type 0 : Indicates positive cumulative flow 1 : Indicates net cumulative flow 2 : Indicates negative cumulative flow
Manual Setting to Modify Heat Unit 0 : Indicates that the heat unit is kilowatt hour ( kW h)

Calibration Method
The water meter is calibrated via constant-flow method. Constant-current method is to mak e the calibration device (s tandard water meter) and tested water meter into stable flow state at a set flow point, calibrate the water meter by measuring accumulative flow at the same time. Different calibration methods may cause errors. If use start-stop method to calibrate the water meter, it may cause errors. Try to extend calibrating time when you use start-stop method to calibrate water meter, and make sure the duration of each turn on time should be more than 60 seconds at least.
Communication
This series of ultrasonic water meters / heat meters has the ability to support multi-protocol communication at the same time. For example, in the same application, the above-mentioned multiple protocols can be used together or mixed. Without doing any firmware or parameter changes.
Communication Interface
The ultrasonic water / heat meter is equipped with 3 physical serial communication interfaces, one is IR infrared communication interface, one is TTL/USART level interface, and the other is RS485/MBUS Parallel dual interface.
USART is a logic level serial interface, suitable for direct connection to other external MCUs , such as communication modules such as NB-iot, Lora, etc., and can also be directly connected to pressure and temperature modules such as SPI interface, etc., with power consumption Very low features.
The IR infrared communication interface is the standard interface of this series of ultrasonic water meters, which meets the standards stipulated in CJ188 . The IR infrared communication interface will automatically enter the low power consumption state within 300 seconds without communication. Touch the button to wake up the infrared interface; the above three physical serial communication interfaces are independent of each other, allowing the three serial ports to be accessed at the same time without interfering with each other.
Serial Communication Interface Default Settings
RS485/MBUS 9600,N,8,1IR 9600,N,8,1 TTL/USART 9600,N,8,1
Change serial port default settings
Serial port parameter setting can be done through a PC -based software named V00_SETUP. The current serial port parameters are displayed in the M26 menu.
Supported Communication Protocols
MODBUS M-BUS CJ188 The above protocols can be supported at the same time. Some protocols can be cross-supported at the same time.
www.iconprocon.com | sales@iconprocon.com | 905.469.9283
14

UFM-H2O Series Ultrasonic Flow Meter (Battery Operated)
Warranty, Returns & Limitations
Warranty
Icon Process Controls Ltd warrants to the original purchaser of its products that such products will be free from defects in material and workmanship under normal use and service in accordance with instructions furnished by Icon Process Controls Ltd for a period of one year from the date of sale of such products. Icon Process Controls Ltd obligation under this warranty is solely and exclusively limited to the repair or replacement, at Icon Process Controls Ltd option, of the products or components, which Icon Process Controls Ltd examination determines to its satisfaction to be defective in material or workmanship within the warranty period. Icon Process Controls Ltd must be notified pursuant to the instructions below of any claim under this warranty within thirty (30) days of any claimed lack of conformity of the product. Any product repaired under this warranty will be warranted only for the remainder of the original warranty period. Any product provided as a replacement under this warranty will be warranted for the one year from the date of replacement.
Returns
Products cannot be returned to Icon Process Controls without Icon's prior authorization. To return a product that is thought to be defective please submit a customer return (MRA) request form and follow the instructions therein. All warranty and non-warranty product returns to Icon Process Controls must be shipped prepaid and insured. Icon will not be responsible for any products lost or damaged in shipment.
Limitations
This warranty does not apply to products which: 1) Are beyond the warranty period or are products for which the original purchaser does not follow the warranty procedures outlined above; 2) Have been subjected to electrical, mechanical or chemical damage due to improper, accidental or negligent use; 3) Have been modified or altered; 4) anyone other than service personnel authorized by Icon Process Controls Ltd have attempted to repair; 5) have been involved in accidents or natural disasters; 6) Are damaged during return shipment to Icon Process Controls.
Icon Process Controls reserves the right to unilaterally waive this warranty and dispose of any product returned to Icon where : 1) There is evidence of a potentially hazardous material present with the product; 2) The product has remained unclaimed at Levelpro for more than 30 days after Icon Process Controls has dutifully requested disposition. This warranty contains the sole express warranty made by Icon Process Controls Ltd in connection with its products. ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY DISCLAIMED. The remedies of repair or replacement as stated above are the exclusive remedies for the breach of this warranty. IN NO EVENT SHALL Icon Process Controls Ltd BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING PERSONAL OR REAL PROPERTY OR FOR INJURY TO ANY PERSON. THIS WARRANTY CONSTITUTES THE FINAL, COMPLETE AND EXCLUSIVE STATEMENT OF WARRANTY TERMS AND NO PERSON IS AUTHORIZED TO MAKE ANY OTHER WARRANTIES OR REPRESENTATIONS ON BEHALF OF Icon Process Controls Ltd. This warranty will be interpreted pursuant to the laws of the province of Ontario, Canada. If any portion of this warranty is held to be invalid or unenforceable for any reason, such finding will not invalidate any other provision of this warranty For additional product documentation and technical support visit www.iconprocon.com | e-mail: sales@iconprocon.com support@iconprocon.com | Ph: 905.469.9283