SKC Preloaded Filters

Cat. No. 225-9033

Operating Instructions

SKC filters are shipped preloaded in the cassettes with end plugs and shrink bands in place. No assembly is required; they are ready to use.

Method & Chemical

NIOSH 7908 for sulfuric acid and phosphoric acid

Filter & Coating

One uncoated quartz filter (Tissuquartz). Two-piece 37-mm cassette. Closed-face sampling configuration

Prior to Sampling

Store at 71.6 F (22 C) for up to 2 years.

Sample Stability

Store samples at 68 F (20 C) for up to 7 days and at ≤ 39.2 F (4C) thereafter up to 28 days.

For information on other available coated filters, go to www.skcinc.com.

How to Use SKC Preloaded Filters

  1. Select one filter cassette for calibrating the flow rate. A red plug secures the inlet, which is clearly marked “inlet,” and a pink plug secures the outlet. Set up the sampling train for calibration with the representative filter cassette in line. For “closed-face” sampling, remove the plugs and connect the cassette to the sampling train. For "open-face” sampling, remove the outlet plug and the cassette inlet section and then connect the cassette to the sampling train. For details on setting up a sampling train, refer to the SKC Sample Setup Guide "Sampling Train – Cyclones” at www.skcinc.com/knowledgecenter.
  2. Calibrate the pump to the desired flow rate using a calibrator.
  3. Replace the cassette used for calibration with a fresh coated filter cassette for sample collection. Attach the cassette to a worker's collar, as close to the breathing zone as possible, by using a filter cassette holder SKC Cat. No. 225-1. Sample for the specified time interval and record the time.
  4. Remove the filter cassette at the end of the specified sampling period with PTFE-coated tweezers and place it in a 10-ml screw-cap plastic vessel. With about 2 ml eluent (extraction) solution (0.0027 M Na2CO3/0.0003 M NaHCO3), rinse material from the inside surfaces of the cassette into the vessel. Add eluent solution into the vessel until a final volume of 5 ml is reached. Replace both end plugs (and the inlet if necessary). Recheck the flow rate using the same cassette and flowmeter used for calibration in Step 2 to ensure that the flow rate has not changed by more than 5%.
  5. See Sample Stability on reverse side for sample storage. Appropriately package samples, blanks, and all pertinent data to send to a laboratory for analysis.

SKC Limited Warranty and Return Policy

SKC products are subject to the SKC Limited Warranty and Return Policy, which provides SKC's sole liability and the buyer's exclusive remedy. To view the complete SKC Limited Warranty and Return Policy, go to skcinc.com/warranty.

Models: 225-9033, Preloaded Filters, 225-9033 Preloaded Filters, Filters

File Info : application/pdf, 2 Pages, 110.06KB

Preloaded Coated Filters 225-9033 OI

References

Microsoft Word for Microsoft 365

Related Documents

Preview SKC Preloaded Coated Filters Cat. No. 225-9014 Operating Instructions
Operating instructions for SKC Preloaded Coated Filters, Cat. No. 225-9014. Details on usage, storage, sampling, and warranty for OSHA ID-214 Ozone filters.
Preview SKC 225-9003 Preloaded Coated Filters: Operating Instructions and Usage Guide
Comprehensive operating instructions for SKC 225-9003 Preloaded Coated Filters, detailing setup, sampling procedures, storage requirements, and warranty information for glutaraldehyde air monitoring.
Preview SKC Preloaded Disposable Parallel Particle Impactors (PPI) Operating Instructions
This document provides operating instructions for SKC Preloaded Disposable Parallel Particle Impactors (PPI) samplers, designed for precise size-selection of respirable and thoracic dust in occupational hygiene applications. Learn about their features, performance, preparation, and sampling procedures.
Preview SKC Impinger Traps Operating Instructions - Models 225-22 & 225-22-01
Operating instructions for SKC Impinger Traps (Cat. Nos. 225-22 and 225-22-01). This guide details how to use, set up, and maintain these traps for effective air sampling, including sorbent replacement and warranty information.
Preview SKC Respirable Dust Cyclone Performance Guide - Air Sampling Equipment
Detailed performance guide for SKC Respirable Dust Cyclones, including optimal flow rates, collection efficiency data relative to ISO/CEN/OSHA/ACGIH standards, and key advantages. Features SKC Aluminum, GS-1, and GS-3 cyclone models.
Preview SKC Cyclone Samplers for Respirable Dust: Operating Instructions
Comprehensive operating instructions for SKC Cyclone Samplers (Models 225-69 and 225-69-37) designed for sampling respirable dust aerosols. Covers preparation, cassette loading, sampler assembly, flow calibration, sampling procedures, post-sampling steps, filter weighing, transportation, and includes a certificate of conformity.
Preview SKC Sampling Guide: Comprehensive Chemical Air Monitoring Methods
SKC's Sampling Guide provides detailed air sampling methods, agency references (NIOSH, OSHA, ASTM), and recommended SKC collecting equipment for a wide range of chemical hazards in industrial hygiene.
Preview SKC GS-1 Single-inlet Cyclone Operating Instructions
Operating instructions for the SKC GS-1 Single-inlet Cyclone, a 10-mm lightweight conductive plastic sampler for collecting respirable dust particles. Includes assembly, calibration, and sampling procedures.