User Manual for DMX4ALL models including: DMX Simple Switch, DMX, Simple Switch, Switch

simple dmx switch english

DMX4ALL GmbH

simple dmx switch english - DMX4ALL GmbH

Simple DMX Switch 3 Trainee project The Simple DMX Switch is a trainee project and was created during the apprenticeship as an electronics technician for devices and systems. Connection Simple DMX Switch 12V GND SW DMX DMX- GND GND DMX- DMX GND DMX- DMX

PDF preview unavailable. Download the PDF instead.

simple dmx switch english
Simple DMX Switch
User manual

Simple DMX Switch

2

For your own safety, please read this user manual and warnings carefully before installation.

Description
The Simple DMX Switch is an easy to configure DMX switch that can be used to switch between two connected DMX input sources.
The Simple DMX Switch has two DMX inputs and one DMX output.
In addition, the Simple DMX Switch has one button input. This input can be used to control the Simple DMX Switch. A switch or push button can be connected to the button input.
In sum the Simple DMX Switch has three operating modes.
It is also possible to control several Simple DMX Switches with only one switch. This makes it doable to switch several DMX universes at the same time with only one switch.
Two status LEDs indicate which DMX signal is currently active.
The top-hat rail housing 350flat for the Simple DMX Switch is available as accessory.

Data sheet
Power supply: Entry: Operation mode settings: Input: Output: Protocol: Status LED display:
Connection: Dimension:

12V DC / 30 mA Button input (SW) 2x Jumper field 2x DMX IN 1x DMX OUT DMX512 LED green (DMX IN 1) LED yellow (DMX IN 2) Screw terminals 29,2mm x 82mm

Simple DMX Switch

3

Trainee project

The Simple DMX Switch is a trainee project and was created during the apprenticeship as an electronics technician for devices and systems.

Connection
POWER 12V

DMX OUT

12V GND
SW DMX+ DMX-
GND

Simple DMX Switch

GND DMXDMX+ GND DMXDMX+

DMX IN 1

DMX IN 2

Simple DMX Switch

4

Status LEDs

The two status LEDs show which DMX signal is currently being output. If status LED for DMX IN 1 (green) lights up, DMX signal 1 is output. If status LED for DMX IN 2 (yellow) lights up, DMX signal 2 is output.

If no status LEDs is on, check the applied voltage.

Operation modes
The Simple DMX Switch can be operated via 3 operating modes. These are adjustable via 2 jumper fields.
Operation modes: · Auto Mode · Toggle Mode · Switch Mode
On the back of the board are small drawings of the jumper settings. So the Simple DMX Switch can be configured without a manual.
In the delivery condition, the Simple DMX Switch is configured within the Auto Mode.

Simple DMX Switch

5

Auto Mode

In the Auto Mode, a DMX signal is outputted preferentially at DMX IN 2.
As long as a DMX signal is present at DMX IN 2, it will be output.
If there is no DMX signal at DMX IN 2, DMX IN 1 is switched automatically and the DMX signal of DMX IN 1 is output.

This mode is suitable for a backup system. As soon as the DMX signal fails at the preferential input, the other input is active immediately.

Jumper settings

J1

J2

1 23 1 23

Operation Mode
Auto Mode Jumper 1: 1 and 2 Jumper 2: free

Jumper J2 can also be plugged. The position of jumper J2 has no influence.

Toggle Mode
With the Toggle Mode, an external button is used to switch between the input signals DMX IN 1 and DMX IN 2.
Pressing the external button switches from DMX IN 1 to DMX IN 2, or rather from DMX IN 2 to DMX IN 1.

Jumper settings

J1

J2

1 23 1 23

Operation Mode
Toggle Mode J1: 2 and 3 J2: 2 and 3

Simple DMX Switch

6

Switch Mode

In the Switch Mode an external switch is used to switch between the input signals DMX IN 1 and DMX IN 2.
If the external switch is open, DMX IN 1 is output.
If the switch is closed, DMX IN 2 is output.

Jumper settings

J1

J2

1 23 1 23

Operation Mode
Switch Mode J1: 2 and 3 J2: 1 and 2

Simple DMX Switch

7

Scaling multiple Simple DMX Switches

The application allows to switch multiple DMX universes / DMX signals with only one switch simultaneously.

To switch two or more Simple DMX Switches simultaneously, all Simple DMX Switches must be connected to the same power supply and to the same switch.

All Simple DMX Switches must also be in the Switch Mode.

Make sure that all Simple DMX Switch devices are operated on the same power supply, switch and in Switch Mode.

Now with the switch it is possible to switch between DMX IN A and DMX IN B.

Example application:

POWER 12V

DMX OUT 1

DMX OUT 2

12V GND
SW DMX+ DMX-
GND 12V GND SW DMX+ DMXGND

Simple DMX Switch

Simple DMX Switch

GND DMXDMX+ GND DMXDMX+ GND DMXDMX+ GND DMXDMX+

DMX IN 1A

DMX IN 1B

DMX IN 2A

DMX IN 2B

Simple DMX Switch

8

Dimension

all details in mm

Simple DMX Switch

9

Accessories

Top hat rail housing 350flat

Netzteil 12V

Simple DMX Switch

10

CE-Conformity

This assembly (board) is controlled by a microprocessor and uses high frequency. In order to maintain the properties of the module with regard to CE conformity, installation into a closed metal housing in accordance with the EMC directive 2014/30/EU is necessary.

Disposal

Electronical and electronic products must not be disposed in domestic waste. Dispose the product at the end of its service life in accordance with applicable legal regulations. Information on this can be obtained from your local waste disposal company.

Warning
This device is no toy. Keep out of the reach of children. Parents are liable for consequential damages caused by nonobservance for their children.

Simple DMX Switch

11

Risk-Notes

You purchased a technical product. Conformable to the best available technology the following risks should not excluded:

Failure risk: The device can drop out partially or completely at any time without warning. To reduce the probability of a failure a redundant system structure is necessary.
Initiation risk: For the installation of the board, the board must be connected and adjusted to foreign components according to the device paperwork. This work can only be done by qualified personnel, which read the full device paperwork and understand it.
Operating risk: The Change or the operation under special conditions of the installed systems/components could as well as hidden defects cause to breakdown within the running time.
Misusage risk: Any nonstandard use could cause incalculable risks and is not allowed.
Waning: It is not allowed to use the device in an operation, where the safety of persons depend on this device.

DMX4ALL GmbH Reiterweg 2A
D-44869 Bochum Germany
Last changes: 22.12.2021
© Copyright DMX4ALL GmbH All rights reserve. No part of this manual may be reproduced in any form (photocopy, pressure, microfilm or in another procedure) without written permission or processed, multiplied or spread using electronic systems. All information contained in this manual was arranged with largest care and after best knowledge. Nevertheless errors are to be excluded not completely. For this reason I see myself compelled to point out that I can take over neither a warranty nor the legal responsibility or any adhesion for consequences, which decrease/go back to incorrect data. This document does not contain assured characteristics. The guidance and the characteristics can be changed at any time and without previous announcement.


GPL Ghostscript 9.52