EasyByMall DSO510
DSO510 Compact Digital Oscilloscope User Manual
モデル: DSO510
Brand: EasyByMall
1. はじめに
The DSO510 is a compact and versatile digital oscilloscope designed for convenient use in various environments. It features a real-time sampling rate of 48 MS/s and a 10 MHz bandwidth, making it suitable for both periodic analog and non-periodic digital signals. With its intuitive automatic function, users can quickly display measured waveforms without complex adjustments.
This manual provides detailed instructions on the setup, operation, and maintenance of your DSO510 oscilloscope. Please read it thoroughly before using the device to ensure proper and safe operation.
2 製品の特徴
- 高性能: 48 MS/s real-time sampling rate and 10 MHz bandwidth.
- ワイドVoltage範囲: 対策voltages up to ±400 V (X10 probe setting).
- 自動機能: One-button auto-adjustment for quick waveform display.
- 統合信号発生器: Built-in 50 kHz function signal generator with various waveform types.
- クリアなディスプレイ: 2.8-inch 320x240 high-definition LCD screen.
- ポータブルデザイン: Compact size (99 x 68.3 x 19.5 mm) and lightweight (294g).
- 長いバッテリー寿命: Built-in 1000 mAh lithium battery provides approximately 4 hours of continuous use.
- USB充電: Convenient 5V/1A USB charging.
- 折りたたみ式スタンド: ハンズフリー操作を可能にする一体型スタンド。

Image: The DSO510 combines the functions of a 10MHz oscilloscope and a signal generator in one compact device.

Image: The DSO510 features a foldable stand for hands-free use and a gear toggle button for easy adjustments.
3. パッケージ内容
以下にリストされているすべてのアイテムがパッケージに含まれていることを確認してください。
- 1 x DSO510 Host Unit
- 1 x P6100 High-Voltageプローブ
- アダプター x 1
- ワニ口クリッププローブ x 1
- 充電ケーブル(USB)×1
- ストラップ x 1
- ユーザーマニュアル x 1

Image: The DSO510 package includes the main unit, high-voltage probe, alligator clip probe, charging cable, adapter, and lanyard.

Image: The DSO510 can be conveniently charged via its USB port using the included charging cable.
4. 仕様
| パラメータ | 価値 |
|---|---|
| モデル | DSO510 |
| リアルタイムSampリンレート | 48MS/秒 |
| 帯域幅 | 10 MHz |
| 垂直感度 | 10 mV/div - 10 V/div |
| 時間基準範囲 | 50 ns/div - 20 s/div |
| 巻tage Range (X1 Probe) | ±40 V (Vpp: 80 V) |
| 巻tage Range (X10 Probe) | ±400 V (Vpp: 800 V) |
| トリガーモード | 自動、通常、シングル |
| トリガーエッジ | Rising Edge / Falling Edge |
| 結合モード | 交流/直流 |
| Calibration Square Wave | Frequency: 1 KHz; Duty Cycle: 50%; Amplitude: 3.3 V |
| 信号発生器周波数 | 0-50KHz |
| 信号発生器のデューティサイクル | 0-100% (Square wave, Sawtooth wave) |
| 信号発生器 Ampリチュード | 0.1-3.0V |
| 信号発生器の波形 | Sine wave, Square wave, Sawtooth wave, Half wave, Full wave, Positive step wave, Inverse step wave, Exponential rise, Exponential fall, DC signal, Multi-audio, Sink pulse, Lorentz wave |
| ディスプレイ画面 | 2.8" LCD, 320 x 240 resolution |
| USB充電 | 5V / 1A |
| リチウム電池容量 | 1000mAh |
| 寸法(長さ×幅×高さ) | 99 x 68.3 x 19.5 ミリメートル |
| 重さ | 294グラム |
| 色 | 黒と青 |

Image: Detailed specifications of the DSO510, highlighting its capabilities compared to similar models.
5. セットアップ
5.1 初期充電
Before first use, fully charge the DSO510. Connect the included USB charging cable to the device's USB port and a 5V/1A USB power adapter (included) or a computer USB port. The charging indicator will show the charging status. A full charge takes approximately 4 hours and provides up to 4 hours of continuous operation.
5.2 プローブの取り付け
Connect the BNC connector of the high-voltage probe (P6100) to the BNC input port on the DSO510. Ensure a secure connection by twisting the connector until it locks into place.
5.3 Probe Compensation (Recommended)
For accurate measurements, it is recommended to compensate the probe. Connect the probe tip to the calibration signal output (usually a 1KHz square wave) on the oscilloscope. Adjust the compensation trimmer on the probe until the square wave displayed on the screen has flat tops and bottoms without overshoot or undershoot.
5.4 Setting Probe Ratio
Ensure the probe ratio setting on the DSO510 matches the physical switch setting on your probe (1X or 10X). If the probe is set to 1X, the oscilloscope should also be set to 1X. A 1X setting measures voltages up to ±40 V, while a 10X setting measures up to ±400 V.
6. 操作手順
6.1 電源オン/オフ
電源ボタン (通常は側面または下部にあります) を長押しして、デバイスの電源をオンまたはオフにします。
6.2 Automatic Measurement (AUTO Button)
For quick setup and display of a stable waveform, press the オート button. The oscilloscope will automatically adjust the time base, vertical sensitivity, and trigger settings to display the measured waveform.
6.3 Navigating Menus and Adjusting Parameters
Use the navigation buttons (up/down/left/right) and the モード button to navigate through menus and adjust parameters. The gear toggle button on the side can also be used for quick adjustments.
6.4 トリガーモード
The DSO510 supports three trigger modes:
- 自動: Automatically triggers and displays the waveform, even if the signal is unstable.
- 普通: Triggers only when the signal meets the trigger conditions. If no trigger occurs, the display remains unchanged.
- シングル: Captures a single waveform when the trigger condition is met and then stops.
6.5 Waveform Adjustment After Pause
When the measurement waveform is paused (STOP mode):
- スイッチ モード to "V H". The wheel button controls the time base (horizontal scale), and the up/down keys control the channel vertical sensitivity.
- スイッチ モード to the arrow keys. The wheel button controls horizontal trigger movement, and the up/down keys control waveform vertical movement.

Image: Instructions on how to adjust the waveform display, including time base, vertical sensitivity, and horizontal/vertical positioning, after pausing the measurement.

Image: The DSO510 is capable of detecting various signal types, including pulse signals and other complex waveforms.
7. 表示インジケーター
The DSO510 display provides various indicators to help you interpret measurements:
- Vertical Unit: ボリュームを表しますtage value for one large grid in the vertical direction.
- トリガーモードインジケーター: Displays "Auto" for automatic trigger, "Single" for single trigger, and "Normal" for normal trigger.
- Probe Ratio: Must be consistent with the 1X/10X switch setting on the probe handle.
- Input Coupling Mode Indicator: "AC" indicates AC coupling, "DC" indicates DC coupling.
- トリガーVoltageインジケーター: Shows the current trigger voltageレベル。
- Trigger Position Indicator: Indicates the horizontal position of the trigger point.
- Baseline Indicator: Shows the 0V reference line.
- Time Base Indicator: Represents the duration for one large grid in the horizontal direction.
- Pause Indicator: "RUN" means operation, "STOP" means pause.
- トリガーエッジインジケーター: Shows whether the trigger is set to rising or falling edge.
8. Signal Generator Function
The DSO510 includes a built-in signal generator capable of producing various waveforms with adjustable frequency, duty cycle, and ampリチュード。
- 周波数範囲: 0-50KHz
- デューティサイクル: 0-100% (for square and sawtooth waves)
- Ampリチュード: 0.1-3.0V
- 波形の種類: Sine wave, Square wave, Sawtooth wave, Half wave, Full wave, Positive step wave, Inverse step wave, Exponential rise, Exponential fall, DC signal, Multi-audio, Sink pulse, Lorentz wave.
To access and configure the signal generator, refer to the specific menu options on the device. Use the navigation buttons to select the desired waveform type and adjust its parameters.
9. メンテナンス
9.1 クリーニング
柔らかく乾いた布で拭いてください。研磨剤入りの洗剤や溶剤は、機器を傷める恐れがあるため使用しないでください。asingまたは画面。清掃する前にデバイスの電源がオフになっていることを確認してください。
9.2 ストレージ
Store the DSO510 in a cool, dry place away from direct sunlight, extreme temperatures, and high humidity. When storing for extended periods, ensure the battery is partially charged (around 50%) to prolong its lifespan.
9.3バッテリーケア
The device uses a built-in lithium battery. Avoid fully discharging the battery frequently. If the device will not be used for a long time, charge it every 3-6 months to prevent deep discharge.
10。 トラブルシューティング
| 問題 | 考えられる原因 | 解決 |
|---|---|---|
| デバイスの電源が入りません。 | バッテリー残量が少ない。電源ボタンが十分に押されていない。 | デバイスを少なくとも30分間充電してください。電源ボタンを3~5秒間押し続けます。 |
| No waveform displayed or waveform is unstable. | Incorrect probe connection; Incorrect trigger settings; Signal too small or too large; Probe ratio mismatch. | プローブがしっかりと接続されていることを確認してください。 オート button. Adjust vertical sensitivity (V/div) and time base (s/div). Verify probe ratio setting matches physical probe switch. |
| Waveform is distorted (e.g., rounded corners on square wave). | Probe compensation issue. | Perform probe compensation as described in Section 5.3. |
| バッテリーの消耗が早いです。 | Aging battery; Continuous high-intensity use. | Ensure the device is fully charged. Reduce screen brightness if possible. If battery life significantly degrades, contact customer support. |
11. 保証とサポート
本製品にはメーカー標準保証が適用されます。具体的な保証条件については、ご購入時に付属の説明書をご覧いただくか、販売店にお問い合わせください。
For technical support, troubleshooting assistance, or inquiries regarding replacement parts, please contact EasyByMall customer service. Please have your product model (DSO510) and serial number (if applicable) ready when contacting support.
メーカー: EasyByMall
モデル番号: H2SV732SH08P7G239N2441
ASIN: B0DLBF6183
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.