ハンテック DSO5102P

Hantek DSO5102P Digital Storage Oscilloscope

ユーザーマニュアル

1。 オーバーview

The Hantek DSO5102P is a high-performance digital storage oscilloscope designed for various electronic measurement applications. It features two channels, a 100MHz bandwidth, and a 1GSa/s real-time sampling rate, making it suitable for hobbyists, educational institutions, and small repair shops.

Key capabilities include waveform storage, USB connectivity for data transfer and system upgrades, and a large color TFT LCD for clear waveform display.

2. パッケージ内容

開梱後、下記のすべての品目が揃っていて良好な状態であることを確認してください。不足品や破損品がある場合は、直ちに販売店にご連絡ください。

Hantek DSO5102P Oscilloscope and included accessories

Image: The Hantek DSO5102P oscilloscope shown with its complete set of accessories, including probes, USB cable, power cable, and a CD.

  • Hantek DSO5102P Digital Storage Oscilloscope Unit (x1)
  • オシロスコーププローブ(2個)
  • USBケーブル(x1)
  • Power Cord (x1) - Note: Power cord type may vary by region. An adapter or replacement may be required for some regions.
  • CD-ROM with Software and Documentation (x1)
  • Certification/Warranty Card (x1)

3 製品の特徴

  • 帯域幅: 100MHz
  • チャンネル: 2つのアナログチャンネル
  • リアルタイムSampルレート: 1GSa/秒
  • レコード長: 40Kポイント
  • 画面: Large 7-inch 64K color TFT LCD with 800x480 resolution
  • 接続性: USB Host for U-disk storage, USB Device for PC communication and remote control
  • 測定機能: Supports 32 types of automatic waveform measurements.
  • トリガーモード: Edge, Pulse, Video, Slope, Alternate.
  • ストレージ: Capable of storing over 1000 waveform information sets.
  • 追加機能: Data hold, relative mode, system upgrade via USB.

4.コントロールとインジケーター

Familiarize yourself with the front panel controls and indicators for efficient operation.

Front panel layout of Hantek DSO5102P oscilloscope with labeled controls

画像: 詳細 view of the Hantek DSO5102P front panel, highlighting key components such as the LCD Display, Power Switch, USB Interface, Analog Channel Input Signal, External Trigger Input Channel, Probe Original, Frequently Used Buttons, Option Buttons, and Executive Controls.

  • LCDディスプレイ: 7-inch color screen for waveform display and menu navigation.
  • 電源スイッチ: Located on the front lower left, used to turn the device on/off.
  • USBインターフェース: For connecting USB storage devices (U-disk) and PC communication.
  • Analog Channel Input (CH1, CH2): オシロスコープのプローブを接続するための BNC コネクタ。
  • External Trigger Input (EXT TRIG): BNC connector for external trigger signals.
  • Probe Original (Compensation Output): Used for probe compensation adjustment.
  • Frequently Used Buttons: Includes buttons for Menu, Utility, Cursor, Display, Acquire, Measure, Auto Set, Run/Stop, Single, and Trigger.
  • オプションボタン(F1~F6): Context-sensitive function buttons corresponding to on-screen menus.
  • Executive Controls: Knobs and buttons for Vertical (position, volts/div), Horizontal (position, sec/div), and Trigger level adjustments.

5. セットアップ

  1. 開梱と検査: Carefully remove the oscilloscope and all accessories from the packaging. Inspect for any signs of physical damage.
  2. 電源接続: Connect the provided power cord to the oscilloscope's power input on the rear panel and then to a suitable AC power outlet. Ensure the voltageはデバイスの要件に一致します。
  3. 初回電源オン: Press the Power Switch on the front panel. The device will perform a self-test and display the main interface.
  4. プローブ接続: Connect the oscilloscope probes to the CH1 and/or CH2 BNC input connectors. Ensure a secure connection by twisting the probe connector clockwise until it locks.
  5. プローブ補正:

    Before taking measurements, it is crucial to compensate the probes to ensure accurate readings. This adjusts the probe's capacitance to match the oscilloscope's input impedance.

    • Connect the probe tip to the Probe Original (compensation output) terminal on the front panel.
    • Connect the probe ground clip to the ground terminal next to the compensation output.
    • を押す 自動設定 button. The oscilloscope will display a square wave.
    • Adjust the compensation screw on the probe body (usually a small plastic screw) using a non-metallic tool until the square wave displayed on the screen has flat tops and bottoms with sharp corners, indicating proper compensation.
    Hantek DSO5102P oscilloscope with a probe connected to the compensation output

    Image: The Hantek DSO5102P oscilloscope with a single probe connected to the probe compensation output, ready for adjustment.

  6. ソフトウェアのインストール(オプション): If you plan to connect the oscilloscope to a PC for remote control or data analysis, install the software from the provided CD-ROM or download the latest version from the Hantek webサイトにアクセスしてください。画面の指示に従ってインストールしてください。

6. 操作手順

This section provides basic instructions for common oscilloscope operations.

6.1 基本的な波形測定

  1. Connect Probe to Circuit: Connect the compensated probe to the circuit point you wish to measure. Ensure the probe's ground clip is connected to the circuit's ground reference.
  2. 自動設定: を押す 自動設定 ボタンを押します。オシロスコープは垂直、水平、トリガー設定を自動的に調整し、安定した波形を表示します。
  3. Adjust Vertical Scale (Volts/Div): 使用 垂直位置 ノブと ボルト/ DIV knob for the respective channel (CH1 or CH2) to adjust the vertical position and amplitude scale of the waveform.
  4. Adjust Horizontal Scale (Sec/Div): 使用 水平位 ノブと SEC/DIV knob to adjust the horizontal position and time base of the waveform.
  5. Adjust Trigger Level: 使用 トリガーレベル knob to set the trigger point on the waveform. This stabilizes the display of repetitive signals.
Hantek DSO5102P oscilloscope displaying various waveforms

Image: The Hantek DSO5102P oscilloscope in operation, showing a hand holding a probe on a circuit board, alongside examples of different waveforms (sine, square, sawtooth, triangular, complex modulated signals) displayed on the screen.

6.2 自動測定

The DSO5102P supports 32 types of automatic measurements. To access these:

  1. を押す 測定 ボタン。
  2. Use the option buttons (F1-F6) and executive controls to select the desired measurement parameters (e.g., Vpp, Vmax, Freq, Period, Rise Time).
  3. 選択した測定値が画面に表示されます。

6.3 Saving Waveforms and Settings

The oscilloscope allows saving waveforms and instrument settings to internal memory or a USB flash drive.

  • 保存する: を押す SAVE/RECALL button. Select the save type (Waveform, Setup, or Bitmap) and destination (internal or U-disk).
  • 思い出すこと: を押す SAVE/RECALL button. Select the recall type and source.

7. メンテナンス

  • クリーニング:

    Regularly clean the exterior of the oscilloscope with a soft, damp 布で拭いてください。研磨剤入りの洗剤や溶剤は使用しないでください。asingまたは画面。清掃する前に、デバイスの電源がオフになっており、プラグが抜かれていることを確認してください。

  • 換気:

    Ensure the ventilation openings on the rear and sides of the oscilloscope are clear of obstructions to allow for proper airflow and heat dissipation. Adequate ventilation is crucial for long-term stable operation.

    後方 view of Hantek DSO5102P oscilloscope showing ventilation

    画像: 背面 view of the Hantek DSO5102P oscilloscope, illustrating the ventilation grilles designed for fast heat dissipation, ensuring safe operation over extended periods.

  • ストレージ:

    オシロスコープを使用しない場合は、乾燥した埃のない環境で、直射日光や極端な温度を避けて保管してください。輸送中は、元の梱包または適切なキャリングケースに入れて保護してください。

  • ファームウェアの更新:

    定期的にHantekの公式ウェブサイトをチェックしてください webファームウェアのアップデートについては、こちらのサイトをご覧ください。アップデートにより、パフォーマンスの向上、機能の追加、バグの修正が行われる場合があります。ファームウェアアップデートパッケージに付属の指示をよくお読みください。

8。 トラブルシューティング

問題考えられる原因解決
電源投入後、表示されません。Power cord not connected, power switch off, or power supply issue.Check power cord connection. Ensure power switch is ON. Verify power outlet is functional.
波形が不安定または歪んでいます。Incorrect probe compensation, improper trigger settings, or probe connection issues.Perform probe compensation. Adjust trigger level and mode. Ensure probe is securely connected to the circuit and oscilloscope.
波形が表示されません。Input signal too small, vertical scale too high, or channel turned off.Adjust Volts/Div to a more sensitive range. Ensure the channel is enabled. Check signal source.
USBストレージが認識されません。Incompatible USB format, faulty USB drive, or connection issue.Ensure USB drive is formatted to FAT32. Try a different USB drive. Reconnect the USB drive.
PC software connection issues.Driver not installed, incorrect COM port, or firewall blocking.Install the correct USB driver. Verify COM port settings in software. Temporarily disable firewall for testing.

9. 仕様

パラメータ価値
モデルDSO5102P
帯域幅100 MHz
チャンネル2
リアルタイムSampルレート1GSa/秒
レコード長40Kポイント
画面7-inch 64K Color TFT LCD (800x480 resolution)
インタフェースUSBホスト、USBデバイス
入力インピーダンス1 MΩ ± 2%, in parallel with 10 pF ± 5 pF
最大入力ボリュームtage400V (DC+AC Peak) CAT I, CAT II
寸法(長さ×幅×高さ)313mm x 142mm x 108mm(約12.3 x 5.6 x 4.3インチ)
重さ約2.08kg(4.59ポンド)
Hantek DSO5102P oscilloscope with dimensions indicated

Image: The Hantek DSO5102P oscilloscope with its physical dimensions (length, width, height) clearly marked.

10. 保証とサポート

Hantek products typically come with a standard manufacturer's warranty. Please refer to the warranty card included in your package for specific terms and conditions, including warranty period and coverage details.

For technical support, product inquiries, or warranty claims, please contact Hantek customer service through their official website or the contact information provided in your product documentation. Keep your purchase receipt and serial number handy when contacting support.

公式ハンテック Webサイト: www.hantek.com

© 2024 Hantek. 無断複写・転載を禁じます。

このマニュアルは情報提供のみを目的としています。仕様は予告なく変更される場合があります。