Cisco C3K-PWR-750WAC

Cisco C3K-PWR-750WAC Power Supply User Manual

設置、操作、保守の手順

1. はじめに

This manual provides essential information for the safe and efficient use of the Cisco C3K-PWR-750WAC hot-plug AC power supply. This power supply is designed for use with compatible Cisco Catalyst network switches, including the 2960, 2960S, 3560E, and 3560V2 series. Please read this manual thoroughly before installation and operation.

2. 安全情報

怪我や機器の損傷を防ぐために、常に次の安全上の注意事項を守ってください。

  • 電源ボリュームを確認してくださいtage matches the power supply's input requirements (AC 100-240 V).
  • 電源装置は濡れた場所や高温の場所では使用しないでください。amp 条件。
  • 電源を開けないでください。asing. 内部にはユーザーが修理できる部品はありません。
  • Disconnect power before installing or removing the power supply. Although it is hot-pluggable, exercising caution is recommended.
  • 感電を防ぐために適切な接地を確保してください。
  • 過熱を防ぐために通気口を空けておいてください。

3. パッケージ内容

パッケージに次のアイテムが含まれていることを確認してください。

  • Cisco C3K-PWR-750WAC 750W AC Power Supply
  • 電源コード(地域限定)
  • Documentation (Quick Start Guide or similar)

4. セットアップとインストール

The Cisco C3K-PWR-750WAC is a hot-pluggable power supply, meaning it can be installed or removed without powering down the host switch, provided the switch supports this feature and has redundant power. Always consult your switch's documentation for specific installation procedures.

4.1. インストール手順

  1. スイッチを準備します。 Ensure the switch is powered on (if hot-plugging) or powered off and disconnected from all power sources (if installing into an empty chassis or replacing a failed unit without hot-plug support).
  2. Locate Power Supply Bay: Identify the power supply bay on your Cisco Catalyst switch.
  3. Remove Blank Panel (if applicable): If a blank panel covers the bay, remove it by loosening any captive screws and pulling it out.
  4. 電源を挿入: Carefully slide the C3K-PWR-750WAC power supply into the bay until it is fully seated. You should feel it click into place.
  5. Secure Power Supply: Tighten any captive screws on the power supply to secure it in the bay.
  6. 電源コードを接続します: Connect the AC power cord to the power supply's inlet and then to a grounded AC power outlet.
  7. 動作確認: Check the status indicators on the power supply and the switch for proper operation. Refer to the "Operating" section for details.
Cisco C3K-PWR-750WAC Power Supply being inserted into a network switch chassis

Figure 1: Illustration of the Cisco C3K-PWR-750WAC power supply. This image shows the general appearance of the power supply, which is designed to be inserted into a compatible network switch bay.

5. 電源の操作

Once installed and connected, the C3K-PWR-750WAC power supply operates automatically. It provides the necessary power to the connected Cisco Catalyst switch. The power supply typically features LED indicators to show its operational status.

5.1. ステータスインジケーター

While specific LED behavior can vary slightly by switch model, common indicators include:

  • 緑/点灯: Indicates the power supply is operating normally and providing power.
  • オレンジ色/点滅: May indicate a fault or a warning condition. Refer to the switch's documentation for specific error codes or patterns.
  • オフ: Indicates no power is being supplied to the unit, or the unit has failed.

Always consult the documentation for your specific Cisco Catalyst switch model for a detailed explanation of its power supply LED indicators.

6. メンテナンス

The Cisco C3K-PWR-750WAC power supply is designed for minimal maintenance. However, periodic checks can help ensure optimal performance and longevity.

  • 換気: Ensure that the air vents on the power supply and the switch chassis are clear of dust and obstructions to allow for proper airflow and cooling.
  • ケーブル配線: Periodically check all power cables for secure connections and signs of damage. Replace any damaged cables immediately.
  • クリーニング: If necessary, gently clean the exterior of the power supply with a soft, dry, lint-free cloth. Do not use liquid cleaners or aerosols.
  • 環境条件: Ensure the operating environment remains within the specified temperature and humidity ranges for the switch and power supply.

7。 トラブルシューティング

If you encounter issues with your C3K-PWR-750WAC power supply, consider the following troubleshooting steps:

  • No Power/Power LED Off:
    • Verify the power cord is securely connected to both the power supply and the AC outlet.
    • Check if the AC outlet is functional by plugging in another device.
    • Ensure the power supply is fully seated in its bay within the switch.
    • If using a power strip or UPS, ensure it is powered on and functioning.
  • Fault LED On/Flashing:
    • This indicates a potential internal fault or an issue with the power input.
    • Try reseating the power supply.
    • If possible, test with a different power cord or AC outlet.
    • If the issue persists, the power supply may be faulty and require replacement.
  • Switch Not Powering On (with power supply LED indicating normal operation):
    • The issue might be with the switch itself, not the power supply.
    • Consult the troubleshooting section of your Cisco Catalyst switch's documentation.

If these steps do not resolve the issue, contact Cisco technical support or your authorized reseller.

8. 仕様

Key technical specifications for the Cisco C3K-PWR-750WAC power supply:

特徴仕様
モデル名C3K-PWR-750WAC
ブランドシスコ
出力ワットtage750ワット
入力ボリュームtageAC 100-240 V
フォームファクターATTX
冷却方法空気
ファン数2
コネクタタイププラグイン
対応デバイスCisco Catalyst 2960, 2960S, 3560E, 3560V2 Switches
商品の寸法 (長さ x 幅 x 高さ)11 x 4 x 2インチ
アイテム重量4 ポンド
メーカー部品番号C3K-PWR-750WAC

9. 保証情報

The Cisco C3K-PWR-750WAC power supply comes with a Five Year Advanced Replacement Warranty from Pure. For detailed terms and conditions, including how to claim warranty service, please refer to the official warranty documentation provided with your product or visit the Cisco support webサイト。

10. テクニカルサポート

For further assistance, technical support, or to report issues not covered in this manual, please contact Cisco support:

  • シスコサポート Webサイト: www.cisco.com/go/support
  • Refer to your product's serial number when contacting support.

© 2023 Cisco Systems, Inc. All rights reserved. 本文書の情報は予告なく変更されることがあります。

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.