WEN 56235i 2350W Inverter Generator

Instruction Manual

NEED HELP? CONTACT US!

Have product questions? Need technical support? Please feel free to contact WEN:

Phone: 1-800-232-1195 (M-F 8AM-5PM CST)

Email: TECHSUPPORT@WENPRODUCTS.COM

For replacement parts and the most up-to-date instruction manuals, visit WENPRODUCTS.COM.

Introduction

Thank you for purchasing the WEN 2350-Watt Inverter Generator. This manual provides essential information regarding safety, preparation, operation, and maintenance. Please record your generator's model and serial number below for future reference and assistance.

Generator Model Number: 56235i

Date of Purchase: ______________________________________________

Purchased From: _______________________________________________

Serial Number: ________________________________________________

To Maximize Lifespan: WEN recommends running your generator at least once a month for 20 to 30 minutes. Start the generator according to instructions and plug in a small load to ensure it is producing electricity.

Specifications

GENERATOR

Model Number56235i
Surge (Starting) Wattage2350 Watts
Rated (Running) Wattage1900 Watts
Rated VoltageAC: 120V, DC: 12V (Cigarette Plug), 5V
Rated AmperageAC: 15.8A, DC: 8.3A (Cigarette Plug), 2.1A/1A (USB)
PhaseSingle
Frequency60Hz
Product Weight39 lbs
Product Dimensions17.3" x 11.5" x 17.7"

ENGINE

Engine Type4 stroke, OHV, single cylinder with forced air cooling system
Engine Displacement79cc
Engine Speed4800 RPM
Fuel Tank Capacity1.06 Gallons (4 L)
Oil Capacity17.1 fl. oz. (0.5 L)
Half-Load Run Time5.7 Hours
Lubrication SystemSplash Lubrication
Spark Plug TypeTorch E5T (NGK BP5H)
Spark Plug Gap0.6 mm - 0.8 mm (0.02 in. - 0.03 in.)
Spark Plug Torque11.1 - 14.7 ft-lbs (15 - 20 Nm)

Service Record

Record the service dates of your generator below. Perform maintenance checks and operations according to the "Maintenance" section of this manual.

Service RecordDateDateDateDateDateDate
Change Oil
Change Spark Plug
Clean Fuel Tank
Clean Air Cleaner
Clean Spark Arrestor

Safety Information

WARNING! Before operating the generator, read all safety warnings and instructions. Failure to follow them may result in electric shock, fire, or serious injury.

Safety Introduction

Safety involves common sense, staying alert, and understanding your tool. This manual contains important information on potential safety concerns, preparation, operation, and maintenance. Observe all warnings on generator labels and in this manual. Failure to follow instructions may result in personal injury.

Note: This safety information does not cover all possible conditions. WEN reserves the right to change product specifications without prior notice. For the most up-to-date manual, visit wenproducts.com or contact customer service.

Keep this manual available to all users throughout the tool's life.

Safety Symbols

Safety symbols are designed to draw attention to potential dangers. Understand their explanations carefully. Warnings alone do not eliminate danger; follow proper accident prevention measures.

DANGER: Indicates a hazard that, if not avoided, will result in death or serious injury.

WARNING: Indicates a hazard that, if not avoided, could result in death or serious injury.

CAUTION: Indicates a hazard that, if not avoided, might result in minor or moderate injury.

CAUTION! (without alert symbol): Indicates a situation that could result in damage to the machine.

Notice Regarding Emissions

Engines are certified to U.S. EPA emission regulations for Small Off Road Equipment (SORE) and operate on regular unleaded gasoline. They may include Engine Modifications (EM) and Three-Way Catalyst (TWC) emission control systems.

Questions? Problems?

For efficient assistance, contact customer service at 1-800-232-1195 (M-F 8-5 CST) or email techsupport@wenproducts.com.

Generator Safety Warnings

WARNING! Do not let comfort or familiarity replace strict adherence to safety rules. Failure to follow instructions may result in serious personal injury.

DANGER: CARBON MONOXIDE

Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide (CO), a poison gas you cannot see or smell. If you smell exhaust, you are breathing CO; even if you don't, you could be.

  • NEVER use a generator inside homes, garages, crawl spaces, or other partially enclosed areas. Deadly CO levels can build up. Fans or open windows do NOT supply enough fresh air.
  • ONLY use a generator outside and far away from windows, doors, and vents, as these openings can pull in exhaust.
  • Even with correct use, CO may leak indoors. ALWAYS use a battery-powered or battery-backup CO alarm. If you feel sick, dizzy, or weak, move to fresh air IMMEDIATELY and see a doctor.

WARNING: RISK OF EXPLOSION. HIGHLY FLAMMABLE

This generator emits highly flammable and explosive gasoline vapors, which can cause severe burns or death if ignited. A nearby open flame can lead to explosion even without direct contact with gasoline.

  • Do not operate near open flame, heat, or any other ignition source. Do not smoke near the generator.
  • Always operate on a firm, level surface.
  • Always turn the generator OFF before refueling. Allow it to cool for at least 2 minutes before removing the fuel cap. Loosen cap slowly to relieve pressure.
  • Do not overfill the fuel tank. Gasoline may expand during operation. Do not fill to the top; allow for expansion. Always check for spilled fuel before operating.
  • If fuel spills, move the generator at least 30 feet away from the spill and wipe clean any spilled fuel before starting the engine.
  • Empty the fuel tank before storing or transporting the generator.

WARNING: Electrical System Connection

If connecting the generator to a building's wiring system for standby power, it MUST be installed by a qualified electrician and connected to a transfer switch as a separately derived system, in accordance with all applicable laws, electrical codes, and the National Electrical Code (NFPA 70). The generator shall be connected to a transfer switch that switches all conductors excluding the equipment grounding conductor. The frame of the generator shall be connected to an approved grounding electrode.

CALIFORNIA PROPOSITION 65 WARNING

This product contains chemicals and produces exhaust known to the State of California to cause cancer, birth defects, and other reproductive harm. For more information, visit www.P65Warnings.ca.gov.

OPERATING ENVIRONMENT

  1. Using a generator indoors can kill you in minutes. Only use a generator outside and far away from windows, doors, and vents.
  2. Do not smoke near the generator.
  3. Do not operate near open flame, heat, or flammable materials. This generator may emit highly flammable and explosive gasoline vapors, which can cause severe burns or even death if ignited. A nearby open flame can lead to an explosion even if it isn't directly in contact with gasoline.
  4. Do not expose the generator to rainy or wet conditions; doing so significantly increases the risk of electrical shock. Never handle the generator, electronic devices, or any cord while standing in water, while barefoot, or when hands or feet are wet.
  5. Always operate the generator on a dry, firm, level surface.
  6. The generator should have at least 5 feet of clearance from buildings or other equipment during operation.
  7. Do not allow children or non-qualified persons to operate the generator.

GENERATOR PREPARATION

  1. Always ground the generator before using it to maximize safety (see "Ground the Generator" section).
  2. Do not overfill fuel tank, as gasoline may expand during operation. Do not fill to the very top of the tank. Leave room for gasoline expansion. Always check for spilled fuel before operating.

GENERATOR OPERATION

  1. Only use the generator for its intended purposes. Modifying or using the generator for operations for which it was not designed may cause hazards and personal injury.
  2. Do not touch bare wires or receptacles (outlets).
  3. Do not exceed the wattage capacity of the generator by plugging in more electrical devices than the unit can handle. This could damage the generator and/or connected electrical devices. Check the operating voltage and frequency requirements of all electrical devices prior to plugging them into the generator.
  4. Allow generator to run for several minutes before connecting electrical devices. Do not start or stop engine with electrical devices plugged in to the receptacles. Failure to do so could damage the generator and/or connected electrical devices.
  5. Do not turn on electrical devices until after they are connected to the generator.
  6. Generators vibrate in normal use. During and after the use of the generator, inspect both the generator as well as extension and power supply cords for damage resulting from vibration.
  7. Do not touch hot parts. This generator produces heat when running. Temperatures near exhaust can exceed 150°F (65°C). Allow generator to cool down after use before touching engine or areas of the generator that become hot during use.
  8. Turn off all connected electrical devices before stopping the generator.
  9. Always turn generator off before refueling. Allow generator to cool for at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.
  10. Turn the engine switch to "OFF" position when the engine is not running.
  11. Empty fuel tank before storing or transporting the generator. Do not store generator or gasoline near furnaces, water heaters, or any other appliances that produce heat or have automatic ignitions. Store the generator and fuel away from sparks, open flames, pilot lights, heat and other sources of ignition.
  12. Always wash hands after handling generator.

CAUTION: Misuse of this generator can damage it or shorten its lifespan.

Warranty Statement

WEN Products is committed to building tools that are dependable for years. WEN warranties are consistent with this commitment and dedication to quality.

LIMITED WARRANTY OF WEN PRODUCTS FOR HOME USE

GREAT LAKES TECHNOLOGIES, LLC ("Seller") warrants to the original purchaser that all WEN consumer power tools will be free from defects in material or workmanship during personal use for a period of two (2) years from the date of purchase or 500 hours of use, whichever comes first. For professional or commercial use, the warranty is ninety days. The purchaser has 30 days from the date of purchase to report missing or damaged parts.

Seller's Sole Obligation: Seller's sole obligation and your exclusive remedy under this Limited Warranty is the replacement of parts, without charge, which are defective in material or workmanship and have not been subjected to misuse, alteration, careless handling, misrepair, abuse, neglect, normal wear and tear, improper maintenance, improper storage, incorrect lubricants/fuels, or other conditions adversely affecting the Product. To make a claim, keep a copy of your proof of purchase that clearly defines the Date of Purchase and Place of Purchase. Place of Purchase must be a direct vendor of Great Lakes Technologies, LLC. Purchasing through third-party vendors voids the warranty. Contact techsupport@wenproducts.com or 1-800-232-1195 with your shipping address, phone number, serial number, required part numbers, and proof of purchase.

Warranty Service: Upon confirmation by a WEN representative, your product may qualify for repairs. Shipping charges for warranty service must be prepaid by the purchaser. The product must be shipped in its original or equivalent container, properly packed, and fully insured, with a copy of the proof of purchase and a description of the problem enclosed. Repairs will be made, and the product will be returned to the purchaser at no charge for addresses within the contiguous United States.

Warranty Exclusions: This limited warranty does not apply to items that wear out from regular usage over time, including filters, spark plugs, voltage regulators, brushes, gaskets, O-rings, wheel kits, batteries, recoil starters, high pressure hoses, spray guns, etc. Any implied warranties shall be limited in duration to two (2) years from the date of purchase.

Limitations: In no event shall Seller be liable for any incidental or consequential damages (including but not limited to liability for loss of profits) arising from the sale or use of this product. Some states and provinces do not allow these limitations.

Legal Rights: This limited warranty gives you specific legal rights, and you may also have other rights which vary by location.

Geographic Scope: This limited warranty applies only to items sold within the United States of America, Canada, and the Commonwealth of Puerto Rico. For warranty coverage in other countries, contact WEN Customer Support. Additional shipping charges may apply for addresses outside the contiguous United States.

Notes

Blank pages are provided for your notes.

THANKS FOR REMEMBERING WEN

Version: V. 2020.07.14

Models: 56235i 2350-Watt Portable Inverter Generator, 56235i, 2350-Watt Portable Inverter Generator, Portable Inverter Generator, Inverter Generator, Generator

File Info : application/pdf, 12 Pages, 675.21KB

PDF preview unavailable. Download the PDF instead.

91rpeFWEdYL

References

Adobe InDesign 14.0 (Windows) Adobe PDF Library 15.0

Related Documents

Preview WEN 56235i 2350W Inverter Generator Instruction Manual
Comprehensive instruction manual for the WEN 56235i 2350W Portable Inverter Generator, covering setup, operation, safety guidelines, maintenance procedures, and troubleshooting tips for optimal performance and longevity.
Preview WEN GN875iX 8750-Watt Inverter Generator Instruction Manual
Comprehensive instruction manual for the WEN GN875iX 8750-Watt Inverter Generator, covering setup, operation, safety, and maintenance. Learn how to safely and effectively use your WEN generator.
Preview WEN GN5602X 5600W Electric Start Portable Generator Instruction Manual
This instruction manual provides comprehensive guidance for the WEN GN5602X 5600W Electric Start Portable Generator, covering setup, safe operation, maintenance, and troubleshooting for reliable power generation.
Preview WEN 56250i 2500W Portable Inverter Generator Instruction Manual
Comprehensive instruction manual for the WEN 56250i 2500W Portable Inverter Generator. Learn about safety features, preparation, operation, maintenance, and troubleshooting for reliable power generation.
Preview WEN DF480iX 4800-Watt Dual Fuel Inverter Generator Instruction Manual
This manual provides essential information for the safe operation, maintenance, and troubleshooting of the WEN DF480iX 4800-Watt Dual Fuel Inverter Generator. Learn about safety features, specifications, and how to get the most out of your generator.
Preview WEN 56225i 2250W Inverter Generator Instruction Manual
This instruction manual provides essential safety, operation, and maintenance information for the WEN 56225i 2250-Watt Inverter Generator. Learn how to safely start, use, and maintain your generator for reliable power.
Preview WEN DF680iX 6800-Watt Dual Fuel Inverter Generator Instruction Manual
Comprehensive instruction manual for the WEN DF680iX 6800-Watt Dual Fuel Inverter Generator, covering safety, operation, maintenance, and specifications.
Preview WEN DF680iX 6800-Watt Dual Fuel Inverter Generator Instruction Manual
This manual provides comprehensive instructions for the WEN DF680iX 6800-Watt Dual Fuel Inverter Generator, covering safety, operation, maintenance, and troubleshooting. Learn how to safely set up, use, and maintain your generator for optimal performance and longevity.