Answer

Jul 26, 2025 - 11:29 AM
To connect conventional switches or buttons to the VIMAR 01475 Smart Automation By Me Plus Module for programming inputs, follow these steps:
1. **Identify the Inputs:** The module has 3 configurable inputs for connecting to conventional switches or buttons. These inputs are labeled as IN1, IN2, and IN3.
2. **Select Suitable Buttons:** Use normally open (N/O) buttons for connecting to the inputs. For example, you can use art. 20008, 19008, or 14008 buttons.
3. **Wiring Connections:** Connect the buttons to the respective inputs as follows:
- Connect the positive (+) terminal of the button to the common (COM) terminal.
- Connect the negative (-) terminal of the button to the input terminal (IN1, IN2, or IN3).
4. **Functionality:** When the connected button is pressed or closed, it will trigger the programmed scenario associated with that specific input. For example, closing IN1 may activate the "Roller shutters UP" scenario.
5. **LED Signaling:** The LEDs paired with the inputs will signal the activation of the inputs by switching on for 3 seconds. Each LED corresponds to a specific input (OUT1 to IN1, OUT2 to IN2, OUT3 to IN3).
By following these steps and using the appropriate buttons, you can easily connect conventional switches or buttons to the VIMAR 01475 Smart Automation By Me Plus Module for programming inputs as per the user manual instructions.