QMark Thermostats & Controls
Control your comfort with easy-to-use features and money-saving controls.
Wall thermostats are a snap to install and easy to program for convenient and smart energy savings.
Featured Thermostats
M601W/M602W
Best Sellers | Easy Installation and Control | Great Low Cost Solution
Description: Mechanical thermostats with snap-action type, suitable for apartment construction. Good thermostat for its value. Ideal for radiant cove heaters and baseboard. Models M601W and M602W have positive OFF. M602W has positive OFF. M601TPW and M602TPW have positive OFF. M611W and M612W offer a tamper-proof feature. M612W has Positive OFF. T100 and T200 feature a built-in heat anticipator for closer room temperature control.
MD26
Description: Mechanical thermostat with snap-action type, sensitive bi-metal construction. Large knob allows for easy adjustment. Model MD26 has Positive OFF.
CNTLTSTDNP1H1C
Advanced Comfort Control | Sleek and Modern Design | Accurate Low Voltage Solution
Description: Digital, Non-Programmable 24V thermostat with exceptional accuracy. Ideal for plenum heaters and HVAC systems. Features electronic switch, 2-wire connection, 40°F to 90°F temperature range, and +/- 1°F accuracy.
LTR2240
Direct Low Voltage Control for High Amp Loads | Allows for BMS Integration | Microprocessor Base Design
Description: Electronic relays designed for silent control of high voltage resistive loads from a low voltage control circuit. Compatible with 24V thermostats. LTR2240 is a dual silent relay with 25A 1HP at 208V/240V, and +/- 1.5°F differential. Can be used with model LT186F01 electronic room sensor or tied to building management systems.
SMARTSERIES® PLUS Digital Touchscreen Control
SmartSeries Plus is the first digital touchscreen capable of running a fully-programmable internal schedule or connecting to a BACnet Building Management System.
Key Features:
- Intelligent Controls for Intelligent Buildings: Connects to Building Management System using BACnet MS/TP protocol.
- Reduced Operations & Maintenance Time: Use of BMS saves facility manager time and reduces personnel costs.
- Control at your Fingertips: Built-in 7-day programmable scheduling feature with occupancy settings for different temperatures.
- Lockable Key Pad: Protects the unit from unauthorized access and/or tampering.
- Temperature Override: Temporary override allows users to set a temperature above programmed setpoints for up to 4 hours.
Product Compatibility Matrix
The following table outlines the compatibility between QMark heaters and thermostats. '+' indicates compatible, '▼' indicates contact MEP, and '■' indicates see SKU Compatibility Chart.
Heater/Thermostat | TL8230A1003/U | TH106A | TH108PLUSA | TH114A240DBA | CNTLTSTDNP1H1C | CNTLSSPBMS | TH5220D1029 | MS26 | MD26 | M601W | M601TPW | M602W | M602TPW | M611W | M612W | M600S* | M600MTP* | T100 | T200 | WT11A | WT12A | WR80 | JC80EP | COS-E Series | SED Series | GFR | QTS | CDF | EFF | QCH | MUH | IUH | CUS900 | MSPH | CONVECTORS | RCC | CP | FRP | OTHER RADIANT |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TL8230A1003/U | + | + | + | + | ■ | ■ | ■ | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
TH108PLUSA | + | + | + | + | ■ | ■ | ■ | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
TH106A | + | + | + | + | ■ | ■ | ■ | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
TH114A240DBA | + | + | + | + | ■ | ■ | ■ | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
CNTLTSTDNP1H1C | ■ | ■ | ■ | ■ | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
CNTLSSPBMS | ■ | ■ | ■ | ■ | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
TH5220D1029 | ■ | ■ | ■ | ■ | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
MS26 | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
MD26 | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
M601W | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
M601TPW | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
M602W | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
M602TPW | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
M611W | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
M612W | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
M600S* | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
M600MTP* | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
T100 | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
T200 | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
WT11A | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
WT12A | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
WR80 | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | |
JC80EP | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + | + |
Notes:
- Programmable thermostats cannot be used with the models listed above.
- Electronic thermostats have amperage minimums and each model has different voltage requirements; please check catalog thermostat specifications.
- 4 Series models require the removal of the internal thermostat from unit. Wire wall thermostat for proper fan operation. See model selection for specific thermostats.
- Low voltage thermostats operate in conjunction with low voltage control systems using relays. Compatible with all standard 24V two wire thermostats.
- The QTS watt units can use either single-pole or double-pole thermostats. The 1104 and 1504 watt units must use a double-pole thermostat (three conductors from thermostat to unit). Does not apply to low voltage thermostats, which need a transformer.
- CDF and EFF Series models require different thermostats based on internal wiring. Wire wall thermostat for proper fan operation. See model selection for specific thermostats. Can not use digital thermostats with this unit.
- Due to the complexity of wiring variations for remote wall thermostats with these products, it is recommended to contact Technical Services for assistance.
SKU Compatibility Chart
HEATER | THERMOSTAT |
---|---|
GFR1500T2F | TH106A, M601W, M611W, T100, MS26 |
GFR2004T2F | TL8230A1003/U, TH106A, TH108PLUSA, M602W, M612W, T200, MD26 |
GFR2404T2F | TL8230A1003/U, TH106A, TH108PLUSA, M602W, M612W, T200, MD26 |
COS-E Series | TH106A, M601W, M611W, T100, WR651 |
SED Series | TH106A, M601W, M611W, T100, WR651 |
CDF548 | MS26, M601W |
CDF542 | MS26, M601W |
CDF547 | MS26, M601W |
CDF558 | MS26, M601W |
CDF552 | MS26, M601W |
CDF557 | MS26, M601W |
EFF1500 | MS26, M601W |
EFF3007 | MS26, M601W |
EFF4008 | MS26, M601W |
EFF4004 | MS26, M601W |
EFF4007 | MS26, M601W |
EFF4804 | MS26, M601W |
EFF4807 | MS26, M601W |
EFF3003 | M601W, M611W |
EFF3006 | M601W, M611W |
EFF4003 | M601W, M611W |
EFF4006 | M601W, M611W |
EFF4803 | M601W, M611W |
EFF4806 | M601W, M611W |
EFF48483 | M601W, M611W |
EFF48483LV | M601W, M611W |
QCH1101F | M601W, MS26 |
QCH1151F | M601W, MS26 |
QCH1202F | M601W, MS26 |
QCH1207F | M601W, MS26 |
Note: Programmable thermostats cannot be used with the models listed above.
Thermostats: Electronic Digital Line Voltage
Action | Type | Watt Rating | 120v | 208v | 240v | 277v | Pilot Duty | Temp. Range (°F) | Differential | Features |
---|---|---|---|---|---|---|---|---|---|---|
TH108PLUSA | Triac: Silent Operation | 12.5A Resistive 2-wire SPST | N/A | N/A | 3000 watts | N/A | No | 40°F to 85°F | Accuracy: Within +/- 0.27°F | Digital, non-programmable 12.5amp model delivers exceptional accuracy. Ideal for radiant ceiling panels and baseboard. Not for fan-forced heaters. |
TH114A240DBA | Electronic Switch | 15 A Resistive 4-wire DPST | N/A | N/A | 3600 watts | N/A | No | 40°F to 85°F | Accuracy: Within 1°F of setpoint | Digital, non-programmable model delivers exceptional accuracy. Ideal for radiant ceiling panels and baseboard. Can be used for fan-forced heaters. |
TH106A | Triac: Silent Operation | 16.7A Resistive 2-wire SPST | Minimum: 2-amp load | 2000 watts | 4000 watts | N/A | No | 40°F to 85°F | Accuracy: Within +/- 0.27°F | Digital, programmable high capacity model delivers exceptional accuracy. Ideal for radiant ceiling panels and baseboard. Can be used for fan-forced heaters and resistive loads. |
TL8230A1003/U | Microprocessor | 16.7 A Resistive 4-wire DPST | N/A | 3120 watts | 3600 watts | N/A | No | 40°F to 85°F | Accuracy: Within 1°F of setpoint | Digital, programmable model delivers exceptional accuracy. Ideal for radiant ceiling panels and baseboard. Can be used for fan-forced heaters. |
Thermostats: Electronic Digital Low Voltage
Action | Type | Watt Rating | 120v | 208v | 240v | 277v | Pilot Duty | Temp. Range (°F) | Differential | Features |
---|---|---|---|---|---|---|---|---|---|---|
CNTLTSTDNP1H1C | Electronic Switch | 24V .015 - 1.0A @ 30V 2-wire | n/a | n/a | n/a | n/a | 24VAC | 40°F to 90°F | Accuracy: Within 1°F of setpoint | Digital, Non-Programmable 24V delivers exceptional accuracy. (Heat Only) |
TH5220D1029 | Electronic Switch | 24V .015 - 1.0A @ 30V 5-wire | n/a | n/a | n/a | n/a | 24VAC | 40°F to 90°F | Accuracy: Within 1°F of set | Digital, Non-Programmable, 24V 2-stage 5-7 wire heat and cool thermostat. One-touch temperature control with exceptional accuracy. Ideal for plenum heaters, and HVAC systems. |
CNTLSSPBMS | Electronic Switch | 24V .015 - 1.0A @ 30V 3-wire | n/a | n/a | n/a | n/a | 24VAC | 40°F to 90°F | Accuracy: Within 1°F of setpoint | Digital, Programmable touchscreen two stage thermostat runs 2/3 elements on stage 1 and full heat for stage 2. Comes with BACnet MS/TP BMS compatibility, 7 day scheduling, cooling mode (Fan-Only), temporary override, vacation mode, and keypad lock. |
Thermostats: Line Voltage
Action | Type | Watt Rating | 120v | 208v | 240v | 277v | Pilot Duty | Temp. Range (°F) | Differential | Features |
---|---|---|---|---|---|---|---|---|---|---|
MS26 | Snap Action | SPST | 22A | 22A | 22A | 18A | No | 50°F to 80°F | +/- 5°F | Economy thermostats, snap action type, used in apartment construction. Good thermostat for its value. Ideal for radiant cove heaters and baseboard. |
MD26 | Snap Action | DPST | 22A | 22A | 22A | 18A | No | 50°F to 80°F | +/- 5°F | Model MD26 has Positive OFF. These bi-metal snap-action thermostats are sensitive. Large knob allows for easy adjustment. |
M601W | Snap Action | SPST | 22A | 22A | 22A | 18A | Yes 125VA | 45°F to 75°F | +/- 4°F | Same as M601W and M602W except the cover mounting cover offers a tamper-proof feature. |
M601TPW | Snap Action | DPST | 22A | 22A | 22A | 18A | Yes 125VA | 45°F to 75°F | +/- 4°F | Same as M601W and M602W except the cover mounting cover offers a tamper-proof feature. |
M602W | Snap Action | SPST | 22A | 22A | 22A | 18A | Yes 125VA | 45°F to 75°F | +/- 2 12°F | Built-in heat anticipator assures closer control of room temperature. |
M602TPW | Snap Action | DPST | 22A | 22A | 22A | 18A | Yes 125VA | 45°F to 75°F | +/- 2 12°F | Built-in heat anticipator assures closer control of room temperature. |
M611W | Snap Action | SPST | 22A | 22A | 22A | 18A | Yes 125VA | 45°F to 75°F | +/- 2 12°F | Built-in heat anticipator assures closer control of room temperature. |
M612W | Snap Action | DPST | 22A | 22A | 22A | 18A | Yes 125VA | 45°F to 75°F | +/- 2 12°F | Built-in heat anticipator assures closer control of room temperature. |
M600S* | Simultaneous switching (double ckt) | DPST | 22A | 22A | 22A | 18A | Yes 125VA | 50°F to 80°F | Accuracy: Within 3°F of setpoint | Simultaneous control of two heating loads. Used where the total load slightly exceeds capacity of a single switch, where two thermostats are impractical. Both switches are calibrated to operate at approximately the same temperature. |
M600MTP* | Modulation (2-stage) | DPST | 22A | 22A | 22A | 18A | Yes 125VA | 45°F to 75°F | Accuracy: Within 3°F of setpoint | One thermostat controls two separate heating circuits and reduces input during light load periods. Second stage activates when temperature drops to approximately 1-1/2ºF below the first stage turn-ON temperature. |
T100 | Snap Action with Heat Anticipator | SPST | 22A | 22A | 22A | 18A | Yes 125VA | 50°F to 90°F | +/- 2 1/2°F | Line voltage thermostat with everything; Performance, reliability, durability, and a large knob. Built-in heat anticipation assures close temperature regulation. Large knob for easy rotation. |
T200 | Snap Action with Heat Anticipator | DPST | 22A | 22A | 22A | 18A | Yes 125VA | 50°F to 90°F | +/- 2 1/2°F | Line voltage thermostat with everything; Performance, reliability, durability, and a large knob. Built-in heat anticipation assures close temperature regulation. Large knob for easy rotation. |
Controls: Specialty Controls
Action | Type | Watt Rating | 120v | 208v | 240v | 277v | Pilot Duty | Temp. Range (°F) | Differential | Features |
---|---|---|---|---|---|---|---|---|---|---|
WR80 | Snap Action Switch | SPST | 25A | 22A | 22A | 18A | Yes 125VA | 20°F to 80°F | +/- 3°F | Rugged design for garages, factories, warehouses and similar commercial and industrial installations. The WR80 can control several heaters by using an external contractor. |
JC80EP | Snap Action Switch | SPST | 25A | 22A | 22A | 22A | Yes 125VA | 20°F to 80°F | +/- 3.5°F | This explosion proof room thermostat is suitable for Class 1, Group D and Class II, Groups E, F, and G locations. |
WT11A | Positive snap action switch | SPDT | 25A | 25A | 25A | 22A | Yes 125VA | 40°F to 110°F | +/- 3°F | NEMA 4X rated. The control has a SPDT output and can be used for heating or cooling (ventilation). Multi-positional mounting offers flexibility in new or existing installations. |
WT12A | DPST | NEMA 4X rated | 25A | 25A | 25A | 22A | Yes 125VA | 40°F to 100°F | +/- 3°F | Nema 4X weatherproof enclosure. The control has a SPDT output and can be used for heating or cooling (ventilation). Multi-positional mounting offers flexibility in new or existing installations. |
LTR SERIES | Electronic Relays | Microprocessor base design | LTR1120: 120V; 22A | LTR208240: 208V/240V; 22A | LTR208240: 208V/240V; 22A | LTR1277: 277V; 19A | These electronic relays have been designed for silent control of high voltage resistive loads from a low voltage control circuit. Inductive motor loads can also be controlled (120V to 240V only). Compatible with 24V thermostats. The relays can be used with model LT186F01 electronic room sensor, providing proportional and integral control. Also can be tied to building management systems. | |||
LTR2240 | Dual Silent Relay | Resistive Inductive | N/A | 25A 1HP, 8.8A | 25A 1HP, 8A | N/A | Yes 125VA | 20°F to 140°F | +/- 1.5°F | This dual level temperature relay may be used to operate two separate heating loads by means of a single low voltage thermostat. Relay is mounted in an enclosure. |
TC1 | Enclosure protection for thermostats. | Material: Impact resistant polycarbonate. Clear. Dimensions are: 7" L x 4.28" H x 2.75" D | Thermostat enclosure kits are designed to protect the thermostat. Circulating slots allow airflow for proper operation. Guards are lockable and a key is provided to maintain security. | |||||||
M600THW | White thermostat cover with built-in thermometer. For M600 Series. | Minimum 50pcs. Allow 4 weeks. | ||||||||
M600THB | Beige thermostat cover with built-in thermometer. For M600 Series stats. | Minimum 50pcs. Allow 4 weeks. |