OYLUS ESW-001

OYLUS Mini Split AC/Heating System - 9000 BTU Ductless Air Conditioner with Heat Pump

Model: ESW-001 | Brand: OYLUS

1. Prodotto finitoview

The OYLUS 9000 BTU Mini Split AC/Heating System provides efficient cooling and heating for spaces up to 450 sq. ft. This unit features inverter technology, a 19 SEER2 cooling rating, and an 8.5 HSPF2 heating rating for energy-efficient operation. It includes multiple modes for comfort control and a quiet sleep mode for undisturbed rest.

2. Caratteristiche del prodotto

  • Powerful 9000 BTU Cooling & Heating: Suitable for rooms up to 450 sq. ft., maintaining temperatures from 61°F to 88°F with inverter technology and a reliable heat pump system.
  • Energy-Efficient Comfort: SEER2 19 cooling and HSPF2 8.5 heating, with smart ECO mode, saving up to 36% on energy costs.
  • Controllo intelligente senza sforzo: Includes a remote control for temperature, fan speed, and mode adjustments. Features a 24-hour timer and a clear LED display that can be turned off.
  • Modalità di sospensione silenziosa: Operates at an ultra-quiet 42dB, gently adjusting temperature for uninterrupted sleep.

3. Cosa c'è nella scatola

The OYLUS Mini Split AC/Heating System comes in two boxes, which may arrive at different times. The package includes all necessary components for installation and operation:

Indoor Unit Box Contents:

  • Unità interna
  • Manuale d'uso
  • Telecomando
  • 12.47ft Indoor-Outdoor Connection Cable
  • 5.91ft Outdoor Connection Cable
  • Indoor Installation Template
  • Piastra di montaggio
  • 9.84ft Gas Pipe
  • 9.84ft Liquid Pipe
  • Nastro
  • 6.56ft Corrugated Water Pipe
  • 6pcs Screws (4.2*50)
  • 6pcs Plastic Expansion Tubes
  • Wall Penetration Plastic Cover
  • Sealing Putty

Outdoor Unit Box Contents:

  • Unità esterna
  • 9.84ft Gas Pipe
  • 9.84ft Liquid Pipe
  • Nastro
  • 6.56ft Corrugated Water Pipe
  • 6pcs Screws (4.2*50)
  • 6pcs Plastic Expansion Tubes
  • Wall Penetration Plastic Cover
  • Sealing Putty

4. Specifiche

Nome del marchioOLIVO
Informazioni sul modelloESW-001
Peso dell'articolo73.9 libbre
Dimensioni del prodotto8.2 x 32.3 x 11.9 pollici
Efficienza (SEER2)19
Capacità3500 Cubic Feet (9000 BTU Cooling Power)
Consumo energetico annuale907 kilowattora all'anno
Livello di rumore42 decibel
Tipo di installazioneSistema diviso
Fattore di formaMini-Split
Caratteristiche specialiFast Cooling, Heating & Cooling Function, Inverter Compressor, Silent Mode, Sleep Mode
ColoreBianco
Voltage115 Volt
Cosatage730 watt
Tipo di materialePlastica
Copertura dell'area del pavimento450 piedi quadrati

5. Configurazione e installazione

Professional installation is recommended for optimal performance and safety. Ensure all local electrical and HVAC codes are followed. The system comes with an installation kit, but specialized tools may be required.

5.1 Disimballaggio e controllo dei componenti

Carefully unbox both the indoor and outdoor units. Verify all components listed in the 'What's in the Box' section are present and undamaged. The indoor unit's mounting plate is pre-installed on the back and needs to be removed before mounting.

OYLUS Mini Split AC/Heating System components

Image: All components included in the OYLUS Mini Split AC/Heating System package, laid out on a floor. This includes the indoor unit, outdoor unit, remote control, various pipes, cables, and installation accessories.

5.2 Montaggio dell'unità interna

Use the provided indoor installation template to mark the drilling points on the wall. Ensure the wall is hard, flat, and firm to avoid vibration and noise. Drill holes and securely attach the mounting plate. The indoor unit will clip onto this plate.

OYLUS Mini Split AC/Heating System indoor unit installation

Image: An indoor unit of the OYLUS Mini Split AC/Heating System being installed on a wall, showing the process of mounting and connecting the unit.

5.3 Connecting Refrigerant Lines and Electrical Wiring

Connect the copper refrigerant lines (gas and liquid pipes) between the indoor and outdoor units. Ensure all connections are tight and sealed. Use thread sealant (like Nylo Blue) on flares for a good seal. Connect the communication and power cables according to the wiring diagram in the user manual. Ensure proper grounding.

Video: A detailed guide on installing a mini split AC unit, including connecting refrigerant lines and electrical wiring. This video is provided by Rellytech Direct, a seller of similar products.

Video: HVAC professional tips for quick and easy mini split setup and installation. This video is provided by YOUDAOX, a seller of similar products.

5.4 Aspirazione del sistema

After connecting the refrigerant lines, the system must be vacuumed to remove any air and moisture. Connect a vacuum pump and manifold gauges to the service ports. Run the vacuum pump for at least 15 minutes until the gauge reads below -14.5 psi. Hold the vacuum for 30 minutes to ensure no leaks. If the pressure rises, check for leaks and re-vacuum.

Video: A detailed guide on installing a mini split AC unit, including connecting refrigerant lines and electrical wiring. This video is provided by Rellytech Direct, a seller of similar products.

5.5 Opening Refrigerant Valves

Once the vacuum test is successful, fully open the liquid and gas valves on the outdoor unit using an Allen wrench. This releases the pre-charged refrigerant into the system. Replace the valve caps securely.

6. Istruzioni per l'uso

The OYLUS Mini Split AC/Heating System offers versatile operating modes for year-round comfort. All functions are controlled via the included remote control.

OYLUS Mini Split AC/Heating System remote control

Image: The remote control for the OYLUS Mini Split AC/Heating System, showing various buttons for mode selection, temperature adjustment, fan speed, and special features.

6.1 Funzioni del telecomando

  • ACCESO/SPENTO: Accende o spegne l'unità.
  • DIREZIONI: Passa attraverso le modalità di funzionamento: Raffreddamento, Riscaldamento, Ventilatore, Deumidificazione, Auto.
  • TEMP ▲/▼: Regola la temperatura desiderata.
  • FAN: Seleziona la velocità della ventola (Auto, Bassa, Media, Alta).
  • SONNO: Activates quiet sleep mode for energy saving and comfort during rest.
  • OSCILLAZIONE: Controlla la direzione del flusso d'aria verticale.
  • ACCENSIONE/SPEGNIMENTO TIMER: Sets a timer for automatic power on or off.
  • ECO: Engages energy-saving ECO mode.
  • TURBO: Fornisce un rapido raffreddamento o riscaldamento.
  • MUTO: Silences remote control beeps.
  • DISPLAY: Turns the LED display on the indoor unit on or off.

Modalità operative 6.2

  • Modalità di raffreddamento: Provides powerful cooling to reach desired low temperatures (e.g., 61°F).
  • Modalità riscaldamento: Delivers warm air to reach desired high temperatures (e.g., 88°F).
  • Modalità ventola: Fa circolare l'aria senza riscaldare o raffreddare.
  • Modalità a secco: Riduce l'umidità nella stanza.
  • Modalità ecologica: Automatically adjusts temperature settings to optimize energy consumption.
  • Modalità risparmio: Gradually adjusts temperature and reduces fan speed for quiet, comfortable sleep.

7. Manutenzione

Regular maintenance ensures the longevity and efficiency of your OYLUS Mini Split AC/Heating System.

7.1 Pulizia del filtro

The indoor unit features a removable and washable filter. Regularly clean the filter to ensure optimal airflow and air quality. Refer to the user manual for detailed instructions on how to remove and clean the filter.

OYLUS Mini Split AC/Heating System removable and washable filter

Immagine: un primo piano view of the OYLUS Mini Split AC/Heating System's removable and washable filter, highlighting its easy maintenance for cleaner air.

7.2 Cura generale

  • Pulire l'esterno delle unità interne ed esterne con un panno morbido e asciutto.amp stoffa.
  • Ensure the outdoor unit's coils are free from debris and obstructions.
  • Check the condensation drain hose for blockages.

8. Risoluzione Dei Problemi

If you encounter issues with your OYLUS Mini Split AC/Heating System, refer to the following common troubleshooting tips. For more complex problems, contact customer support.

8.1 Problemi comuni e soluzioni

  • L'unità non si accende: Controllare l'alimentatore, l'interruttore automatico e le batterie del telecomando.
  • Raffreddamento/riscaldamento insufficiente: Ensure filters are clean, doors/windows are closed, and temperature settings are appropriate.
  • Rumore insolito: Controllare che non vi siano parti allentate o ostruzioni nella ventola.
  • Perdita d'acqua: Controllare che il tubo di scarico non sia piegato o ostruito.

9. Garanzia e supporto

OYLUS is committed to providing quality products and customer satisfaction. Your OYLUS Mini Split AC/Heating System comes with a standard return policy and optional protection plans.

  • Politica di ritorno: Resi facili entro 30 giorni.
  • Piani di protezione: Sono disponibili piani di protezione opzionali di 3 e 4 anni per una copertura estesa.
  • Assistenza clienti: For any inquiries or assistance, please refer to the contact information provided in your User Manual or visit the OYLUS Store on Amazon.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.