VIVOHOME VH1784
Serie VIVOHOME VG 7.2 CFM 2-StagManuale utente del kit pompa per vuoto HVAC e manometro a 4 vie
Modello: VH1784
For R12, R134a, R22, R502, R410a Auto HVAC Systems and Commercial Use
1. Introduzione
This manual provides comprehensive instructions for the safe and efficient operation, maintenance, and troubleshooting of your VIVOHOME VG Series 7.2CFM 2-Stage HVAC Vacuum Pump and 4-Way Manifold Gauge Kit. Please read this manual thoroughly before initial use and retain it for future reference.
2. Informazioni sulla sicurezza
WARNING: Always wear appropriate safety goggles and gloves when operating this equipment. Ensure proper ventilation when handling refrigerants. Refer to local regulations for refrigerant handling and disposal.
- Do not operate the vacuum pump without sufficient oil.
- Prima dell'uso, assicurarsi che tutti i collegamenti siano saldi e privi di perdite.
- Avoid contact with refrigerants.
- Do not use with flammable refrigerants classified as A2L or A2.
- Scollegare l'alimentazione prima di effettuare qualsiasi intervento di manutenzione.
3. Contenuto della confezione
Verifica che tutti gli articoli elencati di seguito siano inclusi nel tuo pacchetto:
- 1 pompa per vuoto da 7.2 CFM
- 2x Bottles of Vacuum Oil (0.24qt & 0.35qt)
- 1x set di manometri
- 2x R134a Quick Couplers
- 4x Color-Coded Hoses
- 2x 1/4" Male to 5/16" Female Adapters
- 1x 1/4" Male to 1/2" Female Adapter
- 1x rubinetto autosigillante per lattina R134a
- 1x Custodia per il trasporto
- Borsa di stoccaggio 1x

Figure 1: Complete VIVOHOME VG Series Kit with all components.
4. Prodotto finitoview
4.1. Vacuum Pump
The VIVOHOME VG Series dual-stage vacuum pump is designed for efficient air removal in HVAC and refrigeration systems.
- Motore: 3/4 HP pure copper motor, running at 3456 RPM for a fast flow rate of 7.2 CFM (204 L/min). Achieves an ultimate vacuum of 15 microns and a partial pressure as low as 0.2 Pa.
- Cooling & Filtration: Features a powerful internal fan, T-shaped motor cooling fins, and mesh ventilation ports to prevent overheating. A coarse filter at the intake blocks dust, and an exhaust filter separates oil mist.
- Design antiriflusso: Prevents oil from returning to the system, ensuring safe and clean operation.
- Funzionalità intuitive: Reinforced aluminum housing for durability, ergonomic handle for transport, oil sight window for monitoring levels, and a convenient oil drain valve.

Figure 2: Vacuum Pump Motor and Performance Details.

Figure 3: Air Inlet Port with Anti-Backflow Design.

Figure 4: Exhaust Port with Filtration System.
4.2. Manifold Gauge Set
The high-precision 4-way manifold gauge provides accurate readings for various HVAC and refrigeration systems.
- Precisione del calibro: Provides accurate, reliable readings with a rubber casing for shock protection and a built-in hanging hook.
- Tubi flessibili: 5.0 ft color-coded rubber hoses (red for high pressure, blue for low pressure, yellow for refrigerant, black for vacuum). Rated for 800 PSI working and 4000 PSI burst pressure.
- Hose Lock-Off Valve: Ensures a secure and airtight seal.

Figure 5: 4-Way Manifold Gauge.

Figure 6: Color-Coded Hoses.
5. Impostazione
5.1. Initial Oil Filling
- Unscrew the oil-filling port cap on the vacuum pump.
- Carefully pour the provided vacuum pump oil into the port until the oil level is between the 'MIN' and 'MAX' marks on the oil sight window.
- Securely replace the oil-filling port cap.

Figure 7: Vacuum Pump Oil.
5.2. Connecting the Manifold Gauge and Hoses
- Attach the color-coded hoses to their respective ports on the 4-way manifold gauge: red to high pressure, blue to low pressure, yellow to refrigerant, and black to vacuum.
- Connect the black vacuum hose from the manifold gauge to the vacuum pump's inlet port.
- For R134a systems, attach the R134a quick couplers to the red and blue hoses. Ensure the quick couplers are in the closed position before connecting.
- For R410a systems, use the included 1/4" Male to 5/16" Female adapters for the low-pressure port.

Figure 8: R134a Quick Couplers.
6. Istruzioni per l'uso
6.1. System Evacuation (Vacuuming)
- Ensure all manifold gauge valves are closed.
- Connect the blue low-pressure hose to the low-pressure service port of the AC system.
- Connect the red high-pressure hose to the high-pressure service port of the AC system.
- Connect the black vacuum hose to the vacuum pump inlet.
- Open the low-pressure and high-pressure valves on the manifold gauge.
- Turn on the vacuum pump. Allow the pump to run for 10-15 minutes, or until the low-pressure gauge reaches -1 bar (or 15 microns).
- Close the low-pressure and high-pressure valves on the manifold gauge.
- Spegnere la pompa del vuoto.
- Disconnect the black vacuum hose from the vacuum pump to prevent backflow.
- Monitor the low-pressure gauge for 5-10 minutes. If the needle remains steady, there are no leaks in the system.
6.2. Carica del refrigerante
- After successful vacuuming, connect the yellow refrigerant hose to the R134a self-sealing can tap (or appropriate can tap for your refrigerant).
- Attach the can tap to the refrigerant can. Turn the can tap clockwise to pierce the can, then counter-clockwise to retract the pin.
- Purge air from the yellow hose by slightly loosening the connection at the manifold gauge's refrigerant port and pressing the valve core until refrigerant escapes, then retighten.
- Turn on the vehicle's engine and set the AC to maximum cooling.
- Slowly open the low-pressure valve on the manifold gauge.
- Invert the refrigerant can (if charging liquid) and allow refrigerant to flow into the system. Monitor the high-pressure and low-pressure gauges, and the refrigerant can's weight (if using a scale) to ensure the correct amount is added according to the vehicle's specifications.
- Once the desired refrigerant level is reached, close the low-pressure valve on the manifold gauge and the valve on the refrigerant can.
- Turn off the vehicle's engine and AC.
- Disconnect the quick couplers from the AC system and the yellow hose from the refrigerant can.
Video 1: VIVOHOME VG Series 7.2 CFM 2 Stage HVAC Vacuum Pump Kit - Demonstrates the vacuuming and charging process for automotive AC systems.

Figure 9: R134a Self-Sealing Can Tap.
7. Manutenzione
7.1. Checking and Changing Vacuum Pump Oil
Regularly check the oil level and clarity through the oil sight window. Change the oil if it appears cloudy, discolored, or below the minimum level.
- Ensure the vacuum pump is off and cool.
- Posizionare un contenitore adatto sotto la valvola di scarico dell'olio.
- Open the oil drain valve and allow all old oil to drain completely.
- Chiudere la valvola di scarico dell'olio.
- Remove the oil-filling port cap and add new vacuum pump oil until the level is between 'MIN' and 'MAX' on the sight glass.
- Replace the oil-filling port cap securely.
7.2. Pulizia dei filtri
Periodically inspect and clean the intake and exhaust filters to ensure optimal performance and prevent contamination.
8. Risoluzione Dei Problemi
8.1. Pump Body Fails to Start or Motor Runs Unstably
If the vacuum pump experiences issues starting or the motor runs erratically, consider the following:
- Abnormal Power Supply Voltage: Assicurarsi che la fonte di alimentazione fornisca un volume stabiletage and that the plug and wiring are in good contact.
- Capacitor Failure or Detached Connectors: Check the capacitor, switch, and ensure all connecting wires are firmly attached.
- Excessive Pump Head Load: Start the pump with the air intake open. If excessive water vapor intake has caused pump chamber rust, rotate the rotor blades counterclockwise with a flat-head screwdriver.
- Temperatura ambiente: At low temperatures (below 5°C), pump oil may crystallize. Under high-temperature conditions (above 40°C), multiple startup attempts may be required.
Video 2: VIVOHOME Pump Body Fails to Start or Motor Runs Unstably - Provides visual guidance for common startup and motor issues.
9. Specifiche
| Produttore | VIVOHOME |
| Numero di parte | VH1784 |
| Peso dell'articolo | 32 libbre |
| Dimensioni del prodotto | 13.1 x 5.1 x 9.5 pollici |
| Misurare | 7.2CFM |
| Colore | Orange, Black, Silver |
| Materiale | Alluminio, Rame, Gomma |
| Quantità del pacchetto dell'articolo | 1 |
| Primo disponibile | 26 marzo 2025 |

Figura 10: Specifiche del prodotto oltreview.
10. Garanzia e supporto
This VIVOHOME product comes with a 1-year warranty. For technical support, warranty claims, or further assistance, please contact VIVOHOME customer service through their official channels.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.