1. Introduzione
This manual provides essential information for the safe and efficient operation of your XWJNE 1200W Pure Sine Wave Power Inverter. This device converts 12V DC battery power to 120V AC household power, suitable for various applications including home, RV, truck, and off-grid solar systems. Please read all instructions carefully before use.
The inverter delivers high-quality pure sine wave output, comparable to commercial power, ensuring compatibility with sensitive electronics. It features a robust metal casing for durability and efficient heat dissipation, along with multiple protection mechanisms for safe operation.
2. Precauzioni di sicurezza
- Assicurare sempre una ventilazione adeguata attorno all'inverter per evitare il surriscaldamento.
- Do not expose the inverter to rain, moisture, snow, liquid, or dust.
- Ensure all connections are secure and correct polarity is observed (red for positive, black for negative).
- The power source should be a deep-cycle battery with a discharge level of 80% or more.
- Avoid connecting the inverter to a power source that exceeds its rated voltage.
- Do not open or attempt to repair the inverter yourself. Refer to qualified personnel for service.
- Utilize the GFCI (Ground Fault Circuit Interrupter) outlets for enhanced electrical safety.
3. Cosa c'è nella scatola
Upon unboxing your XWJNE 1200W Pure Sine Wave Power Inverter, please verify that all the following items are included:
- Unità inverter
- Car Battery Cables (2.62ft 7AWG positive and negative)
- Manuale di istruzioni
- Fuses (2 x 40A 32V)
- Ground Wire (1.64ft)
- Cacciavite

Figure 1: Included accessories with the XWJNE 1200W Power Inverter.
4. Prodotto finitoview
Pannello frontale
The front panel of the inverter features the main AC output ports, USB charging ports, and the power switch. The integrated LCD display provides real-time operational status and fault indications.
- Interruttore di alimentazione: Attiva/disattiva l'alimentazione principale dell'inverter.
- GFCI AC Output Ports: Two 120V AC outlets with Ground Fault Circuit Interrupter for safety.
- Porte USB: Includes 1 USB-A port (5V 2.4A) and 1 Type-C port for charging devices.
- Schermo LCD: Mostra il volume immessotage, volume di uscitatage, load power, battery level, frequency, and temperature.
Pannello posteriore
The rear panel is equipped with the DC input terminals for battery connection and cooling fans.
- Terminale positivo (+): Terminale rosso per il collegamento positivo della batteria.
- Terminale negativo (-): Terminale nero per il collegamento negativo della batteria.
- Ventole di raffreddamento: Two high-efficiency fans for heat dissipation.

Figura 2: Disposizione dei pannelli anteriore e posteriore.
5. Impostazione
5.1 Collegamento a una batteria
- Assicurarsi che l'interruttore di alimentazione dell'inverter sia in posizione OFF.
- Connect the red battery cable to the inverter's positive (+) terminal and then to the positive terminal of your 12V DC battery.
- Connect the black battery cable to the inverter's negative (-) terminal and then to the negative terminal of your 12V DC battery.
- Serrare saldamente tutti i collegamenti per evitare contatti allentati e archi elettrici.
5.2 Messa a terra dell'inverter
For safety, connect the included green/yellow ground wire to the inverter's grounding screw and to a proper earth ground point (e.g., vehicle chassis, building ground rod).
5.3 Collegamento del telecomando
If your inverter model includes a remote control, connect the remote cable to the designated remote port on the inverter's front panel. This allows for convenient monitoring and control of the inverter from a distance.

Figura 3: Inverter collegato a una batteria da 12 V.
Video 1: Detailed unboxing and setup guide for the XWJNE 1200W Pure Sine Wave Inverter, demonstrating cable connections and initial power-up.
6. Funzionamento dell'inverter
6.1 Accensione/Spegnimento
- After connecting the battery, switch the main power button on the inverter to the ON position.
- The LCD display will illuminate, showing current status.
- To turn off the inverter, switch the main power button to the OFF position.
Display LCD 6.2
The intelligent LCD screen provides comprehensive information about the inverter's operation:
- Ingresso volumetage: Visualizza il volume CCtage dalla batteria.
- Volume di uscitatage: Mostra il volume CAtage viene fornito.
- Potenza di carico: Indica il wat correntetage viene disegnato dai dispositivi connessi.
- Potenza della batteria: Visual representation of the battery's charge level.
- Frequenza: Visualizza la frequenza di uscita (60 Hz).
- Temperatura: Mostra la temperatura interna dell'inverter.
- Icone di stato: Indicators for normal operation, low voltage protezione, oltre voltage protection, overload protection, over temperature protection, short circuit protection, and reverse polarity protection.

Figure 4: LCD Display Details.
6.3 Funzione di controllo remoto
The wired remote control allows you to monitor and operate the inverter from a convenient location. It mirrors the main LCD display, providing real-time data and control over the inverter's ON/OFF state.
6.4 Utilizzo esamples
The XWJNE 1200W inverter is versatile for various applications:
- Backup domestico: Accendi gli elettrodomestici essenziali durante il giornotages.
- RV & Truck: Provides AC power for mobile living and travel.
- Sistemi solari fuori rete: Integrates with solar setups for independent power.
- Attività all'aperto: Powers tools and devices for camping, work sites, etc.

Figura 5: Diverse applicazioni dell'inverter.
7. Manutenzione
7.1 Sistema di raffreddamento
The inverter is equipped with intelligent cooling fans that automatically activate when the internal temperature exceeds 45°C (113°F) or when the load exceeds 50% of its rated capacity. This ensures optimal operating conditions and extends the lifespan of the device. Keep the fan vents clear of obstructions.

Figura 6: Ventole di raffreddamento dell'inverter.
8. Risoluzione Dei Problemi
The inverter is designed with multiple protection mechanisms to ensure safe and reliable operation. The intelligent LED screen will display specific fault codes to help identify and resolve issues.
8.1 Meccanismi di protezione
- sotto-volumetage Protezione: Shuts down the inverter if the input voltage scende troppo in basso.
- Over-volumetage Protezione: Protegge da un volume di input eccessivamente elevatotage.
- Protezione da sovraccarico: Activates if the connected load exceeds the inverter's capacity.
- Protezione da sovratemperatura: Si spegne se la temperatura interna diventa troppo alta.
- Protezione da cortocircuito: Prevents damage from output short circuits.
- Protezione da inversione di polarità: Guards against incorrect battery connections.
8.2 Fault Display Codes
Refer to the LCD screen for specific fault codes (e.g., F01 for Parameter Configuration Fault, F07 for Output Overload, F12 for Battery Undervoltage) to diagnose and address operational issues.

Figure 7: Fault display codes and their explanations.
9. Specifiche
| Caratteristica | Valore |
|---|---|
| Dimensioni del prodotto | 7.48 x 3.39 x 11.81 pollici |
| Peso dell'articolo | 8 libbre |
| Numero modello articolo | 25IVBTK-12HW-12V-120 |
| Marca | XWJNE |
| Usi consigliati | Home, Off-Grid, RV, Truck, Vehicle |
| Fonte di alimentazione | Alimentato a batteria |
| Cosatage | 1200 watt |
| Capacità della batteria | 100 Amp Hours (recommended minimum) |
| Ingresso volumetage | 12V CC |
| Volume di uscitatage | 120 V CA |
| Frequenza di uscita | 60 Hz |
| Forma d'onda | Onda sinusoidale pura |
| Potenza di picco | 2400W |
| Efficienza | >90% |
| Corrente senza carico | <1A |
10. Garanzia e supporto
XWJNE is committed to providing reliable products and excellent customer service. For any inquiries or assistance, please contact our 24-hour customer service team. Refer to the product packaging or official websito per dettagli specifici sulla garanzia.