1. Introduzione
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the NPQPNAFC EACT-25 2P 25A 220V/230V AC Modular Contactor. Please read these instructions thoroughly before use and retain them for future reference.
2. Prodotto finitoview e Caratteristiche
The EACT-25 is a household AC modular contactor designed for controlling electrical circuits. It features a manual control handle switch for flexible operation.
- Designed for AC 50Hz or 60Hz circuits with a rated operating voltage di 230V.
- Rated operating current up to 25A for AC-7a usage and up to 10A for AC-7b usage.
- Suitable for circuits with breaking capacity below 6kA.
- Utilized for remote connection or disconnection of circuits.
- Common applications include automatic power cut-off or connection in homes, apartments, and hotels.

Figura 1: Davanti view of the NPQPNAFC EACT-25 AC Modular Contactor, showing the manual control switch and terminal connections.
3. Informazioni sulla sicurezza
Avvertimento: L'installazione e la manutenzione elettrica devono essere eseguite esclusivamente da personale qualificato. Il mancato rispetto di queste istruzioni può causare scosse elettriche, incendi o lesioni gravi.
- Scollegare sempre l'alimentazione prima di installare, effettuare la manutenzione o rimuovere il contattore.
- Assicurare una corretta messa a terra e un cablaggio adeguato in base alle normative elettriche locali.
- Non superare il volume specificatotage e le valutazioni correnti.
- Proteggere il dispositivo dall'umidità e dalle temperature estreme.
- Prima di ripristinare l'alimentazione, verificare che tutti i collegamenti siano saldi.
4. Configurazione e installazione
The EACT-25 contactor is designed for DIN rail mounting.
- Montaggio: Securely attach the contactor to a standard 35mm DIN rail. Ensure it clicks into place firmly.
- Cablaggio: Per i collegamenti corretti, fare riferimento allo schema elettrico presente sul dispositivo e riportato di seguito.
- Connect the main power supply to terminals 1 and 3 (A1 and L).
- Connect the load to terminals 2 and 4 (A2 and N).
- Assicurarsi che tutti i collegamenti dei cavi siano ben saldi e adeguatamente isolati.
- Verifica: After wiring, double-check all connections for correctness and security before applying power.

Figura 2: The EACT-25 contactor securely mounted on a standard DIN rail, demonstrating its modular design for electrical panels.

Figura 3: Lato view of the contactor showing the integrated wiring diagram for terminals A1, A2, 1, 2, 3, and 4, indicating input and output connections.
5. Istruzioni per l'uso
The EACT-25 contactor features a manual control handle switch with multiple positions:
- "Auto" Position: In this position, the contactor operates automatically based on the control signal applied to terminals A1 and A2. This is the standard operating mode for automated systems.
- "O" (Off) Position: This position manually opens the contacts, disconnecting the load from the power supply, regardless of the control signal.
- "P" (On) Position: This position manually closes the contacts, connecting the load to the power supply, regardless of the control signal.
To change the operating mode, gently slide the handle switch to the desired position. Ensure the switch clicks firmly into place.
6. Manutenzione
The EACT-25 contactor is designed for minimal maintenance. However, periodic checks are recommended to ensure optimal performance and safety.
- Ispezione visiva: Ispezionare regolarmente il contattore per verificare la presenza di eventuali segni di danni fisici, scolorimento o collegamenti allentati.
- Pulizia: Ensure the contactor and its surroundings are free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
- Tenuta del terminale: Periodically check that all terminal screws are tight to prevent overheating and poor connections.
- Condizioni ambientali: Assicurarsi che l'ambiente operativo rimanga entro gli intervalli di temperatura e umidità specificati.
7. Risoluzione Dei Problemi
Se il contattore non funziona come previsto, considerare i seguenti problemi comuni:
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Contactor does not energize in "Auto" mode. | Nessun controllo voltage (230V) to A1/A2 terminals, or control circuit fault. | Verificare il volume di controllotage supply. Check control circuit wiring and components. |
| Il carico non riceve alimentazione. | Contactor contacts open (manual switch in "O" or no control signal), main power supply issue, or load wiring fault. | Check manual switch position. Verify main power supply. Inspect load wiring. |
| Contactor hums or overheats. | Loose connections, incorrect voltage, or internal fault. | Disconnect power and check all terminal connections for tightness. Verify supply voltage. If problem persists, replace the unit. |
Se le procedure di risoluzione dei problemi non risolvono il problema, contattare un elettricista qualificato o il produttore per assistenza.
8. Specifiche
The following specifications apply to the NPQPNAFC EACT-25 2P 25A 220V/230V AC Modular Contactor:

Figura 4: Detailed dimensions of the EACT-25 contactor, showing measurements for height, width, and depth for installation planning.
| Parametro | Valore |
|---|---|
| Modello | EACT-25 |
| Poli | 2P |
| Corrente nominale (AC-7a) | 25A |
| Corrente nominale (AC-7b) | 10A |
| Vol. operativo nominaletage | 220 V/230 V CA |
| Frequenza | Frequenza 50/60 Hz |
| Capacità di rottura | Below 6kA |
| Montaggio | Guida DIN da 35 mm |
| Dimensioni del pacco | 1.18 x 0.79 x 0.39 pollici |
| Peso dell'articolo | 1.1 libbre |
9. Garanzia e supporto
Per informazioni sulla garanzia o assistenza tecnica, fare riferimento alla confezione del prodotto o contattare il rivenditore. Conservare la ricevuta d'acquisto come prova d'acquisto.