1. Introduzione
Questo manuale fornisce istruzioni dettagliate per l'installazione, il funzionamento e la manutenzione del Ampinvt TG-6000W48V Hybrid Solar Inverter. This advanced unit integrates an inverter, AC battery charger, MPPT solar charge controller, and an AC auto-transfer switch into a single, efficient system. It is designed to provide reliable pure sine wave power for various applications, including residential, commercial, and mobile setups.

Figura 1: Fronte view del Ampinvt TG-6000W48V Hybrid Solar Inverter, showcasing its display and controls.
2. Caratteristiche principali
- Sistema integrato: Combines inverter, AC battery charger, MPPT solar charge controller, and AC auto-transfer switch.
- Alta efficienza: Transfer efficiency above 85%, with MPPT tracking efficiency up to 98%.
- Uscita onda sinusoidale pura: Provides continuous, stable pure sine wave output, suitable for sensitive electronics.
- Split Phase Output: Available at 240Vac (HOT1+HOT2) and 120/240Vac output simultaneously.
- Corrente di carica regolabile: Max charge current adjustable from 0-35A, allowing customization or disabling of charging.
- Robust MPPT Controller: 100A MPPT controller supports 48V lead-acid (Seal, AGM, Gel, Flooded) and lithium (LiFePO4, User Mode) batteries.
- Elevato input fotovoltaico: Maximum PV Array Power of 5600W and MAX PV input voltage di 150V CC.
- Protezioni complete: Includes battery low/high voltage alarm, over temperature, overload, and short circuit protection.
- Built-in AVR Stabilizer: Isolates surge interference and ensures stable voltage.

Figura 2: Oltreview of the inverter's integrated features, including its 35A AC charger and 100A MPPT controller.
Figure 3: The inverter is compatible with a wide range of home and office appliances, providing 6000W continuous output.
Figure 4: The inverter supports various 48V battery chemistries, including SLD, FLD, GEL, AGM, and Lithium, with a user-configurable mode.
3. Installazione e configurazione
3.1 Precauzioni di sicurezza
Before installation, ensure all power sources are disconnected. Always wear appropriate personal protective equipment. Consult a qualified electrician for wiring if you are unsure. Do not expose the inverter to water or excessive humidity.
3.2 Montaggio
Mount the inverter in a well-ventilated area, away from direct sunlight, heat sources, and flammable materials. Ensure adequate clearance around the unit for proper airflow. The unit should be mounted vertically on a sturdy surface.
3.3 Collegamenti di cablaggio
Follow the connection diagram carefully. Ensure all connections are secure and properly insulated. Incorrect wiring can cause damage to the inverter or connected devices.
Figure 5: Comprehensive connection diagram illustrating how to integrate solar panels, utility grid, generator, battery, and various AC loads with the hybrid solar inverter.
- Ingresso pannello solare: Connect your solar array to the PV+ and PV- terminals. Ensure the maximum PV input voltage (150V DC) and power (5600W) are not exceeded.
- Collegamento della batteria: Connect the 48V battery bank to the battery terminals, observing correct polarity (positive to positive, negative to negative).
- Ingresso CA: Connect the utility grid or generator AC power to the AC input terminals.
- Uscita CA: Connect your AC loads (appliances, lights, etc.) to the AC output terminals. The inverter provides 120V/240V split phase output.
- Messa a terra: Assicurarsi che l'inverter sia correttamente collegato a terra per evitare pericoli elettrici.
4. Modalità operative
IL Ampinvt TG-6000W48V Hybrid Solar Inverter features five distinct working modes to optimize power management based on your specific needs:
- AC/Line Priority Mode: In this mode, the inverter prioritizes AC power from the utility grid or generator as the primary input. It provides AC output and automatically charges the connected battery bank. If AC power is unavailable, the inverter will seamlessly switch to battery power.
- Modalità priorità batteria: This mode prioritizes power supply from the battery bank. The inverter will draw power from the batteries until a low voltage protection threshold is reached. At this point, it will automatically transfer to market power (utility grid) supply. Once the battery is sufficiently recharged (e.g., by solar or AC charging), it will switch back to battery power.
- Modalità ecologica: Designed for energy saving, the inverter enters an automatic sleep state and stops output when the load is less than 10% of its capacity. When the load increases above 10%, the inverter automatically wakes up and resumes normal inversion.
- Generator Mode: This mode is specifically for use with unstable generator 240V power. The generator's AC output is connected to the inverter's AC input. The inverter's built-in AVR (Automatic Voltage Regulator) regulates the voltage and automatically matches the 60Hz municipal frequency, ensuring a stable output voltage within the normal operating range for your appliances.
- Modalità non presidiata: Quando la batteria è scaricatage drops to a low level, the inverter enters a standby (power-saving) state. It will remain in this state until the battery voltage recovers to a user-defined value (e.g., after solar charging). Once the voltage is restored, the inverter will automatically resume normal output, enabling fully automatic, unattended operation.
5. Manutenzione
Una manutenzione regolare garantisce la longevità e le prestazioni ottimali del vostro inverter. Eseguite periodicamente i seguenti controlli:
- Pulizia: Keep the inverter and its ventilation openings clean and free from dust and debris. Use a dry cloth for cleaning.
- Connessioni: Controllare periodicamente tutti i collegamenti elettrici per verificarne la tenuta e l'assenza di segni di corrosione. Collegamenti allentati possono causare surriscaldamento e scarse prestazioni.
- Stato della batteria: Monitor your battery bank's health according to the battery manufacturer's guidelines. Ensure proper charging and discharge cycles.
- Ambiente: Assicurarsi che l'ambiente di installazione rimanga entro gli intervalli di temperatura e umidità specificati.
6. Risoluzione Dei Problemi
Questa sezione fornisce soluzioni ai problemi più comuni che potresti riscontrare. Per problemi non elencati qui, contatta l'assistenza clienti.
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Nessuna potenza in uscita | Batteria scaricatage, Overload, Input AC not present | Controllare il volume della batteriatage, Reduce load, Check AC input connection |
| Inverter alarm sounds | Overload, Over temperature, Battery fault | Reduce load, Ensure proper ventilation, Check battery connections/health |
| Batteria non in carica | Charging current set to 0A, Solar panels not connected/producing, AC input fault | Adjust charging current setting, Check solar panel connections/output, Verify AC input |
| Display non funzionante | No power to inverter, Display fault | Check battery and AC input connections, Contact support if power is present |
7. Specifiche
| Parametro | Valore |
|---|---|
| Nome del modello | TG-6000W48V |
| Cosatage | 6000W (6KW) |
| Fonte di alimentazione | Alimentato a energia solare e a batteria |
| Dimensioni del prodotto | 14.2 x 6.9 x 20 pollici |
| Peso dell'articolo | 78.8 libbre |
| Potenza massima del generatore FV | 5600W |
| Max ingresso PV Voltage | 150V CC |
| Volume batteriatage | 48 V CC |
| Ingresso CA Voltage | 240 V CA |
| Volume di uscita CAtage | 120V/240VAC Split Phase |
| Regolatore di carica MPPT | 100A |
| Caricabatterie CA | Regolabile 0-35A |
| Efficienza di trasferimento | Oltre il 85% |
| Produttore | Top one power |
Figure 6: Physical dimensions of the inverter and a list of items included in the package.
8. Cosa c'è nella scatola
Dopo aver disimballato, verificare che siano presenti tutti gli articoli:
- 1 volte Ampinvt TG-6000W48V Hybrid Solar Inverter
- 1 x cavo della batteria
- 1 x Manuale utente (questo documento)
9. Garanzia e supporto
This product comes with a manufacturer's warranty. For specific warranty terms, duration, and claim procedures, please refer to the warranty card included with your product or contact the manufacturer directly. For technical support, troubleshooting assistance, or spare parts, please reach out to OAE customer service through their official channels.
Figura 7: Il Ampinvt Hybrid Solar Inverter is suitable for a wide range of practical applications, from residential homes to remote base stations.